우리나라 성인의 전동칫솔 사용이 치석 형성 치주조직 상태에 미치는 영향: 제7기 국민건강영양조사 자료 활용 (A study on the association between electric toothbrush use on calculus formation and periodontal tissue condition in Korean adults: 7th Korea National Health and Nutrition Examination Survey)

  • 이소현;안하영;정윤숙
    • 한국치위생학회지
    • /
    • 제24권4호
    • /
    • pp.343-352
    • /
    • 2024
  • Objectives: This study aimed to assess the relationship between electric toothbrush use and the presence of community periodontal index (CPI) code calculus among Korean adults. Methods: Data from the 7th Korea National Health and Nutrition Examination Survey were analyzed. Multiple logistic regression analysis with a complex sampling design was conducted, adjusting for general characteristic factors. Analyses were performed using SPSS Statistics 29.0. Results: Among the participants, the prevalence of electric toothbrush users was 5.3%. Within this group, 4.7% had periodontal disease, whereas 5.9% did not (p=0.025). Even after adjusting for general characteristics factors in model II of electric toothbrush use, the odds ratio remained statistically significant at 0.791 (95% CI: 0.631-0.992) in all cases. Conclusions: Electric toothbrush use appears to be associated with potential benefits in managing the CPI code calculus distribution; however, evidence supporting this notion remains insufficient. The study findings suggest that these results could be a basis for future studies related to oral hygiene products and the design of oral health promotion programs.

고정식 교정환자에서 치주건강 유지에 대한 전동치솔의 효과 (Comparison of electric and manual toothbrushes on periodontal health in fixed orthodontic patients)

  • 박성준;이기헌;황현식
    • 대한치과교정학회지
    • /
    • 제35권4호
    • /
    • pp.286-294
    • /
    • 2005
  • 고정식 교정치료 환자들은 구강내 교정장치로 인해 치태제거에 어려움이 있으며 보다 효과적인 치태제거를 위해서는 특별한 구강위생교육 및 치솔질이 필요하다. 본 연구는 고정식 교정치료 환자에서 일반적으로 사용되고 있는 교정용 수동치솔에 비해 전동치솔이 치주건강 유지에 도움이 되는지 알아보기 위하여 시행되었다. 고정식 교정장치에 의해 교정치료 예정인 환자 40명을 대상으로 고정식 교정장치 부착 1개월 후 치솔의 종류에 따라 전동치솔군과 수동치솔군으로 연구대상을 임의 구분하고 각각에 맞는 구강위생교육을 시행한 후 3개월, 0개월, 9개월, 12개월 후 치태지수, 치은염지수, 치은출혈지수, 치주낭깊이, 그리고 상대적부착상실을 측정하였다. 전동치솔의 경우 교정용 브러쉬 헤드를 가진 Braun Oral-B 사의 전동치솔을, 수동치솔의 경우 Butler사의 교정용 치솔을 사용하게 하였다. 수동치솔군의 경우 실험기간 동안 치태지수는 통계적으로 유의하게 감소한 반면 (p<0.001), 치은염지수, 치은출혈지수는 통계적 유의차를 보이지 않았고, 치주낭깊이, 부착상실은 통계적으로 유의하게 증가하였다 (p<0.01). 전동치솔군의 경우에는 치은출혈지수와 함께 치주낭깊이, 부착상실이 통계적 유의차를 보이지 않았으며, 치태지수, 치은염지수는 통계적으로 유의하게 감소하였다 (p<0.001). 한편 치태지수, 치은염지수, 치은출혈지수의 경우 변화양상에 있어 전동치솔군과 수동치솔군 간에 유의한 차이를 보이지 않은 반면, 치주낭깊이와 부착상실의 경우 전동치솔군에서는 처음 상태가 읜정하게 유지된 반면, 수동치솔군에서는 치주낭깊이와 부착상실이 증가하는 양상을 나타내었으며 이러한 변화양상의 수동치솔과 전동치솔간 차이는 통계적으로 유의하였다 (p<0.05). 이상의 결과는 고정식 교정장치로 치료받는 환자에서 수동치솔보다 전동치솔이 치주건강 유지에 더 효과적임을 시사하였다.

고정식 교정 환자에서 전동치솔 효과에 관한 연구 (A comparative study of electric and manual toothbrushes on oral hygiene status in fixed orthodontic patients)

  • 박창헌;황현식;이기헌;홍석진
    • 대한치과교정학회지
    • /
    • 제34권4호
    • /
    • pp.363-370
    • /
    • 2004
  • 고정식 교정장치를 부착한 경우 장치주위의 치태 축적 가능성이 증가되고 이로 인해 치은염, 법랑질 탈회 등의 부작용이 초래 될 수 있는 바 치태 제거를 위한 효과적인 칫솔질이 필요하다. 본 연구는 교정환자에서 일반적으로 사용되고 있는 치솔에 비하여 전동치솔이 구강위생에 도움이 되는지 알아보기 위하여 시행되었다. 고정식 장치에 의한 교정치료 예정인 환자 34명을 본 연구의 대상으로 하여 고정식 교정장치 부착 전에 치태지수, 치은염지수, 치은출혈지수를 측정하였다. 장치 부착 4주 후에 각 지수를 측정한 다음, 연구대상을 치솔의 종류에 따라 전동치솔군과 수동치솔군으로 임의 구분하여 수동치솔 또는 전동치솔을 사용하도록 구강위생교육을 각각 시행하였다. 이때 전동치솔의 경우 본체는 Braun Oral-B D9511을 브러쉬 헤드는 Braun Oral-B Ortho OD 15-1을 사용하게 하였으며, 수동치솔의 경우는 Butler G.U.M 124를 사용하게 하였을. 구강위생교육 4주 및 8주 후에 각 지수를 측정한 다음 시간 경과에 따른 전동치솔군과 수동치솔군의 구강위생 상태를 비교 분석하여 다음과 같은 결과를 얻었다. 1. 고정식 교정장치 부착 4주 후 치태지수, 치은염지수, 치은출혈지수 모두 증가 양상을 나타내었다. 2. 구강위생교육 후 치태지수, 치은염지수, 치은출혈지수 모두 감소 양상을 나타내었다. 3. 치은염지수, 치은출혈지수의 경우 감소양상이 수동치솔과 전동치솔군 간의 유의한 차이를 보이지 않았다. 4. 치태지수의 경우 수동치솔에 비해 전동치솔군에서 감소효과가 유의하게 크게 나타났다. 이상의 연구 결과는 고정식 교정장치로 치료받는 환자에서 전동치솔이 구강위생에 도움이 됨을 시사하였다.

Effects of an electric toothbrush combined with 3-color light-emitting diodes on antiplaque and bleeding control: a randomized controlled study

  • Kwon, Chakyoung;Lee, Jae-Mok;Suh, Jo-Young;Seo, Seung-Jun;Lee, Youngkyun;Kim, Yong-Gun
    • Journal of Periodontal and Implant Science
    • /
    • 제50권4호
    • /
    • pp.251-259
    • /
    • 2020
  • Purpose: This randomized controlled study aimed to evaluate the effects of an electric toothbrush with 3 colors of light-emitting diodes (LEDs) on antiplaque and bleeding control. Methods: This randomized, placebo-controlled, double-blinded, parallel-group clinical trial included 50 healthy adults with gingivitis, who were randomly assigned to 2 groups. The experimental group used electric toothbrushes with 3 colors of LEDs and the control group used the same electric toothbrush as the experimental group, but with LED sources with one-hundredth of the strength. The subjects used the electric toothbrush 3 times a day for 4 minutes each time. As clinical indices, bleeding on marginal probing (BOMP), the Löe-Silness gingival index (GI), and the Turesky-Quigley-Hein plaque index (QHI) were assessed at baseline, at 3 weeks, and at 6 weeks. Results: There were significant decreases in all clinical indices (BOMP, GI, QHI) in both the experimental and control groups compared to baseline at 3 weeks and at 6 weeks. In a comparison between the experimental and control groups, no statistically significant differences were observed for any clinical indices at 3 weeks (P>0.05). However, at 6 weeks, statistically significant differences were observed between the experimental and control groups in BOMP and GI, which are indicators of gingival inflammation (P<0.05). Conclusions: This study demonstrated that an electric toothbrush combined with 3-color LEDs reduced gingival bleeding and inflammation after 6 weeks.

전동칫솔모의 작동형태에 따른 치면세균막 제거율에 관한 실험연구 (An experimental study on plaque removal effect through the acting types of the electric toothbrushes)

  • 이천희;안선하;장영호
    • 한국치위생학회지
    • /
    • 제11권4호
    • /
    • pp.465-474
    • /
    • 2011
  • Objectives : The removal of most reliable mechanical dental plaque that is to say tooth brushing was generalized to control of dental plaque, many oral health goods have also developed due to the effect differences followed by individual habit. The electric toothbrush have studied and developed widely as major field of study that electric toothbrush having various moving phase was sold and developed at the market. Methods : Accordingly author studied about selling electric toothbrushes shape (vibration type, ultra-sonic minuteness vibration type, semi rotation type) to raise the efficiency after comparing to the moving them that total 8 groups classified by poor tooth models for example normal set of tooth, crowding tooth, bracket attached tooth, prosthetic status etc. and executed plaque removal effect on the tooth through comparing experiment. Results : The removal rate of artificial plaque on the tooth was improved in proportion to the increase of tooth brushing time(p<0.05). The ultra-sonic minuteness vibration and semi rotation type was superior to toothbrush of vibration type comparing to the removal rate of plaque on the tooth(p<0.05). Conclusions : The electric toothbrush of supersonic minuteness vibration and semi rotation type can be recommended most of tooth types regardless of oral tooth setting status for example, normal set of tooth, crowding tooth, bracket attached tooth, porcelain tooth.

Effect of 125 Hz and 150 Hz vibrational frequency electric toothbrushes on the rate of orthodontic tooth movement and prostaglandin E2 levels

  • Anadha N. Gujar;Prashantha Govinakovi Shivamurthy
    • 대한치과교정학회지
    • /
    • 제53권5호
    • /
    • pp.307-316
    • /
    • 2023
  • Objective: To evaluate the effects of an electric toothbrush with vibrational frequencies of 125 Hz and 150 Hz on the orthodontic tooth movement (OTM) rate and the production of prostaglandin E2 (PGE2). Methods: Out of thirty patients (aged 18-25 years; 16 females and 14 males), ten patients each formed Group A and B, who used electric toothbrushes with 125 Hz and 150 Hz vibrations, respectively. The remaining ten patients (Group C) served as the control group and did not use electric toothbrushes. The rate of OTM and levels of PGE2 using microcapillary pipettes were calculated before the start of retraction (T0), on the 30th day (T1), on the 60th day (T2), and on the 90th day (T3) from the start of retraction in all the groups. Results: There was a statistically significant difference in the mean OTM values and PGE2 levels in all three groups at different time intervals, with the maximum difference seen in Group B compared to Group A and least in Group C at T1, T2 and T3. Conclusions: The rate of OTM and levels of PGE2 were highest in patients who used an electric toothbrush with 150 Hz mechanical vibration compared to those who used an electric toothbrush with 125 Hz mechanical vibration and least in patients who did not use an electric toothbrush. Mechanical vibration led to an increase in the PGE2 levels and accelerated the OTM.

교정환자의 구강건강관리에 관한 지식도와 태도 및 구강위생용품 사용실태 (Research on the usage of oral hygiene devices and the general knowledge, attitude on oral health care in the orthodontic patients)

  • 민희홍;라은주;전지현;박영남
    • 한국치위생학회지
    • /
    • 제12권2호
    • /
    • pp.399-407
    • /
    • 2012
  • Objectives : Purpose of this research is to determined the general knowledge on oral health and the usage of oral hygiene products in the orthodontic patients and try to provide an appropriate oral hygiene products for the patients. Methods : Orthodontic patients who visited a dental clinic in Daejeon were selected and data from 352 patients were collected. Questionnaire based on survey was conducted from 1st of March to 30th in 2011 and all the data was analysed by using SPSS statistical program (VER 15.0). Frequency analysis, $x^2$ test, T-test and the amount of diurnal variance analysis (one-way ANOVA) were also used. After that, scheffe's post-test method was conducted. Results : According to the general characteristics of oral health care knowledge score was $2.87{\pm}0.60$, the attitude score was $2.96{\pm}0.57$. toothbrush replacement cycle were less than 3 months (p=0.007, p=0.000) and frequency of brushing one day more than three times higher in patients with knowledge to help attitude. according to the sex, age, and duration of orthodontic treatment with oral hygiene devices of usage was higher in the calibration toothbrush usage, awareness was higher in the interdental toothbrushes. according to the type of orthodontic devices from the oral hygiene devices usage, removable group was the orthodontic toothbrush and electric toothbrush group were highest in the 'unknown', the fixed group was orthodontic toothbrush(67.3%) and electric toothbrushes(40.8%) was higher in the usage. Patients who used oral hygiene devices such as orthodontic tooth brush, interdental brush, electric toothbrush, water pik and fern solution showed wider knowledge on oral health care and oral hygiene devices compared to patients who answered as does not aware of oral hygiene devices and never used these products before. Conclusions : Orthodontic patient's oral health attitudes, knowledge, and oral hygiene devices usage are the general characteristics of the highest in the orthodontic toothbrush usage, awareness was higher in the interdental brush. Water pik and fern solution, rubber and gingival interdental stimulator turned massage does not use or low. Based on results from research, overall orthodontic patients who visited a dental clinic had low awareness and usage of oral hygiene devices. Therefore, it is required to educate general publics and the orthodontic patients and also promote the importance of usage of oral hygiene devices.

전동칫솔의 작동횟수에 따른 치면세균막 제거율에 관한 융합연구 (An convergence study on the effect of plaque removal through the number of operations of the electric toothbrushes)

  • 문경희;이지영;김장미
    • 한국융합학회논문지
    • /
    • 제10권2호
    • /
    • pp.21-28
    • /
    • 2019
  • 본 연구는 진동회전 방식의 전동칫솔의 진동, 회전에 따른 치면세균막 제거율을 실험하여 전동칫솔 선택의 폭을 넓히고자 하였다. 진동회전타입의 전동칫솔 중 진동회전수가 다른 칫솔 3가지를 선정하였다. A: Oral-B D12(7,600회 회전), B: Oral-B D16(20,000회 진동, 7,600회 회전), C: Oral-B D20(40,000회 진동, 8,800회 회전). 세가지 칫솔의 세정력을 확인하기 위해 인공치면세균막을 치아에 1회, 2회, 3회 코팅하여 각 10회씩 2초간 세정하였다. 실험 후 잔여치면세균막를 촬영하여 Image J 프로그램을 활용하여 분석하였다(p<0.05). 연구에 따르면, 코팅한 모든 치면의치면세균막 제거율이 C칫솔이 가장 높았다. 연구결과를 토대로 치과종사자는 구강위생환경을 평가 한 후, 구강상태에 따른 적절한 칫솔의 추천과 교육이 필요할 것으로 사료된다.

증등도 치주염에서 칫솔모 도달이 힘든 부위의 치태 및 치은염 감소에 대한 Sonicare $Elite^{\Box}$ 의 효과 (Efficacy of the Sonicare $Elite^{\Box}$ in plaque removal and reduction of gingival inflammation from hard-to-reach sites of the moderate periodontitis)

  • 홍지연;정성원;엄유정;채경준;정의원;김창성;최성호;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제36권3호
    • /
    • pp.693-703
    • /
    • 2006
  • The purpose of this study was to evaluate the efficacy of the Sonicare $Elite^{(R)}$ power toothbrush in plaque removal and reduction of gingivitis from hard-to-reach sites of the moderate periodontitis compared to regular manual toothbrush in 12 week follow-up. 82 subjects with incipient to moderate periodontitis were randomly assigned to use either the manual or sonic brush, instructed in its use, and asked to brush 2 times a day for 2 minutes. Plaque scores were taken at baseline, 1, 4, 12 weeks using Silness & $L\ddot{o}e$ plaque index and gingival inflammation was assessed by the $L\ddot{o}e$ & Silness gingival index. The results were as follows. 1. The Sonicare $Elite^{(R)}$ power toothbrush showed a significant reduction(p<0.0001) of the plaque(Silness & $L\ddot{o}e$) and gingival inflammation(Loe & Silness). 2. The Sonicare $Elite^{(R)}$ power toothbrush showed a significant better reduction of plaque and gingivitis(p<0.05) than the manual toothbrush after 1, 4, and 12 weeks. 3. The Sonicare $Elite^{(R)}$ power toothbrush demonstrated a significant reduction(p<0.0001) of the plaque in interproximal sites(p<0.0001), buccal sites(p<0.0001) and the lingual sites(p=0.00l8) of the teeth. 4. The Sonicare $Elite^{(R)}$ power toothbrush demonstrated a significant reduction(p<0.0001) of the gingival inflammation in the interproximal sites(p<0.0001), the buccal sites(p<0.0001) and the lingual sites(p<0.0001) of the teeth. The results of this study support the findings that Sonicare $Elite^{(R)}$ power toothbrush has a great potential to remove the plaque and resolve the gingival inflammation during the period of 12 week.