• Title/Summary/Keyword: Electric strength

Search Result 1,181, Processing Time 0.04 seconds

Dynamic Responses of Electrorheological Fluid in Steady Pressure Flow (정상압력 유동 하에서 전기유변유체의 동적 응답)

  • Nam, Yun-Joo;Park, Myeong-Kwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2879-2884
    • /
    • 2007
  • Dynamic responses of electrorheological (ER) fluids in steady pressure flow to stepwise electric field excitations are investigated experimentally. The transient periods under various applied electric fields and flow velocities were determined from the pressure behavior of the ER fluid in the flow channel with two parallel-plate electrodes. The pressure response times were exponentially decreased with the increase of the flow velocity, but increased with the increase of the applied electric field strength. In order to investigate the cluster structure formation of the ER particles, it was verified using the flow visualization technique that the transient response of ER fluids in the flow mode is assigned to the densification process in the competition of the electric field-induced particle attractive interaction forces and the hydrodynamic forces, unlike that in the shear mode determined by the aggregation process.

  • PDF

Transient Response of an Electrorheological Fluid in Shear Flow (전단 유동 하에서 전기유변유체의 과도응답 특성)

  • Choi, Byung-Ha;Nam, Yun-Joo;Park, Myeong-Kwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.6
    • /
    • pp.411-417
    • /
    • 2009
  • The transient shear stress response of an electrorheological fluid is investigated experimentally. The characteristic time constants of an electrorheological fluid sheared between two concentric cylinders were obtained under various electric field strengths and shear rates. Also, two experimental modes are adopted to investigate the effect of the shear flow on the dynamic behavior of the fluid; one is that the electric field is induced before shearing, and the other is the electric field is induced after shearing. From the difference in the response time between two modes, the cluster formation time were obtained. The response times were decreased with the increase of the shear rate, irrelatively of the electric field strength. The cluster formation time were monotonically increased with increase of shear rate, and thereafter, were converged with a certain value.

Development of ultra high voltage-large capacity O.F cable (초고압 대용량 O.F 케이블의 개발)

  • Kang, S.H.;Lee, K.J.;Kim, C.S.;Choi, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.265-267
    • /
    • 1991
  • In this paper, we describe the development of 345kv OF cables to contain also the cable employing new insulation paper, PPLP (Poly propylene Laminated paper). The cables all show very excellent properties, especially PPLP cable has less the dielectric loss and better the impulse & A.C strength than the one employing the conventional paper. Therefore, according to use PPLP cable, it seems to be several advantages such as the compact of system, the increasing capacity, and the decreasing energy loss etc.

  • PDF

Imaging of Magnetic Nanoparticles Added in Transformer Oil According to the Electric and Magnetic Fields

  • Lee, Jong-Cheol;Lee, Sang-Yeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.219-220
    • /
    • 2013
  • The phenomenology of liquid breakdown has been an area of interest for many years but is still not fully understood. Moreover, it was known that the behavior of magnetic nanoparticles in transformer oil could affect the dielectric breakdown voltage positively or negatively. In this study, we have imaged the magnetic nanoparticles in a transformer oil in-situ using an optical microscopic set-up and a microchannel according to the electric and magnetic fields applied. And we have calculated numerically dielectrophoresis and magnetophoresis forces, which must be the driving mechanisms to move magnetic nanoparticles in the fluid. It was found that when the electric field is applied the magnetic nanoparticles in the fluid experience an electrical force directed toward the place of maximum electric field strength. And when the external magnetic field is applied, the magnetic nanoparticles form long chains oriented along the direction of the field.

  • PDF

Electro-optic Electric Field Sensor Utilizing Ti:LiNbO3 Symmetric Mach-Zehnder Interferometers

  • Jung, Hong-Sik
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.47-52
    • /
    • 2012
  • The use of a $Ti:LiNbO_3$ symmetric Mach-Zehnder interferometric intensity modulator with a push-pull lumped electrode and a plate-type probe antenna to measure an electric field strength is described. The modulator has a small device size of $46{\times}7{\times}1mm$ and operates at a wavelength of $1.3{\mu}m$. The output characteristic of the interferometer shows the modulation depth of 100% and 75%, and $V_{\pi}$ voltage of 6.6 V, and 6.6 V at the 200 Hz and 1 KHz, respectively. The minimum detectable electric field is ~1.84 V/m, ~3.28 V/m, and ~11.6 V/m, corresponding to a dynamic range of about ~22 dB, ~17 dB, and ~6 dB at frequencies of 500 KHz, 1 MHz and 5 MHz, respectively.

Evaluation of Construction Applicability for Slurry Backfill Materials of Underground Power Cable (지중송전관로 유동화 뒷채움재의 시공성 평가)

  • Kim, Dae-Hong;Cho, Hwa-Kyung;Oh, Gi-Dae;Lee, Dae-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1068-1075
    • /
    • 2006
  • Flow-able backfill is known as soil-cement slurry, void fill, and controlled low-strength material (CLSM). The benefits of CLSM include reduced equipment costs, faster construction, re-excavation in the future, and the ability to place material in confined spaces such as narrow parts nearly impossible for compaction or perimeter of underground power cables. A review of some recent full-scale tests carried out by KEPRI on slurry backfill materials for application in underground power cable was presented. Based on this research, applicability was assessed and compare to results of laboratory tests for improved slurry materials with optimal mixture contents.

  • PDF

Dielectric Strength Enhancement of Extra High Voltage XLPE Power Cable by Micro-Structural Treatment on Semi-Conductive Interface (XLPE 계면에서의 라멜라 구조 제어 및 전기적 특성)

  • Cho, Dae-Hee;Shim, Sung-Ik;Youn, Bok-Hee;Lee, Sang-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.293-296
    • /
    • 2004
  • 초고압 케이블의 절연물질로 널리 사용되고 있는 가교 폴리에틸렌의 전기적 특성은 라멜라 결정 조직의 밀도와 라멜라 조직의 성장방향과 밀접한 관련이 있는 것으로 알려지고 있다. 본 연구에서는 반도전 물질에 2종의 첨가제를 이용하여 처방한 3종의 반도전 컴파운드에 대하여 시편 제작 조건에 따른 미세 조직을 제어하여 폴리에틸렌의 미세 조직을 변화시킴으로써, 라멜라 조직이 전기적 특성에 미치는 영향을 분석하였다. 전기적 특성은 AC 절연파괴 전압을 측정하였으며, 미세 조직 변화를 조사하기 위하여 TEM 이미지 분석 통하여 라멜라 밀도를 통계적으로 정성 분석하여 상관관계를 규명하였다.

  • PDF

Analysis of time-varying low-frequency electric magnetic field emitted from electric rolling stocks fed by VVVF inverter (VVVF 인버터로 구동되는 전기철도차량에서 방출되는 시변 저주파 전자계 분석)

  • Jang, Dong-Uk;Kim, Joo-Rak;Kim, Heol-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.507-513
    • /
    • 2010
  • This paper is described the analysis of time-varying low-frequency electric magnetic field emitted from electric rolling stocks fed by VVVF inverter, in reference to allowable magnitude for exposures to time-varying electromagnetic field issued by International Commission on Non-Ionizing Radiation Protection(ICNIRP). The level of the magnetic field strength was measured, in reference to the standard for occupational environments, which takes into account the public person's protection against the excessive emission of the low-frequency magnetic field, 5 Hz ~ 2 kHz.

  • PDF

A Study on Developing the Magnetic Wedge Material and its Application (자성웨지 국산화 개발 및 그 적용에 관한 연구)

  • Choi, Jong-Koo;Kang, Yi-Kuk;Bae, Byeong-Choon;Hong, Sung-Il
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1482-1484
    • /
    • 1996
  • To apply Magnetic wedges to the motor, comparing with not applying, showes its performance change of efficiency increse, reduction of temperature rise, harmonics, and magnetic noise. The motor specification and test condition are 37kW-4P-380V-60Hz,squirrel-cage, three phase induction motor with semiclosed type slots. The result of load test to compare with nonmagnetic wedges showed 1.5% increment of efficiency at 100% load and $8.0^{\circ}C$ decrement of temperature rise at stator coil. And for developing the magnetic wedge matrial, its manufacturing process was setting and TG-DTA, optical microscope, SEM, bending strength and permeability were investigated into the material made of through the process.

  • PDF

A Study on Design Techniques for Strength of Supporters in Straight Over-head Distribution Lines (직선 가공배전선로 전주강도 설계방안 연구)

  • Kim, Sang-Kyu;Wong, Yoon-Chan;Sun, Sang-Jin;Kim, Chang-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.412-413
    • /
    • 2008
  • 가공배전선로는 야외에 시설되어 하계의 태풍 및 동계의 설해와 같은 자연재해에 상시 노출됨에 따라 지지물 절손 피해가 발생할 우려가 높다. 따라서 직선으로 시설되는 전주가 절손되지 않도록 설계지역의 기상조건을 감안하여 전주강도가 충분한지 여부를 검토하여야 한다. 그러나 현업에 종사하는 설계원들이 어떠한 방법으로 전주강도를 검토하는지에 대한 이해가 부족한 실정이다. 따라서 본 고에서는 전주강도 계산과 관련하여 연구된 이론을 설명하였고, 그 이론을 바탕으로 장경간개소와 표준경간에 설치되는 전주에 대한 설계방안을 연구한 결과를 사례를 통해서 설명하였다. 본 고에서 제시한 방법에 따라 설계를 시행한다면 직선으로 시공되는 전주들의 강도가 태풍 및 설해에 대비하여 충분히 확보됨에 따라 재해 시에도 이로 인한 전주 절손 피해가 예방될 수 있을 것으로 기대되며, 또한 전기고장 예방을 통한 고품질 전력확보에도 기여할 것으로 기대된다.

  • PDF