• 제목/요약/키워드: Electric shielding

검색결과 126건 처리시간 0.026초

고주파 웰딩기의 유해 전자파 차단에 관한 연구 (A Research on the Shielding of Injurious Electromagnetic Field for High-frequency Welder)

  • 장석용;심재형;김준안;백인환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.447-450
    • /
    • 2002
  • In the surrounding of the electric machinery and equipments occurring of using the electromagnetic fields, other electric machinery or equipments are induced the malfunctions by the radiated and leaked electromagnetic fields. And the human hazardous problems by that effect are being discussed frequently. So efficiently shielding technique of injurious electromagnetic field for high frequency welder is discussed in this paper.

  • PDF

전기전도성 분말과 알루미늄 코팅 유리섬유를 사용한 자동차용 크래쉬패드의 전자파 차폐 특성에 관한 연구 (A Study on the Electromagnetic Shielding Characteristics of Crash Pad Using Electrically Conductive Powders and Al-coated Glass Fiber as Filler in Automotive)

  • 조홍;정선경;김병우
    • 한국분말재료학회지
    • /
    • 제21권2호
    • /
    • pp.124-130
    • /
    • 2014
  • The automotive industry is moving from the internal combustion engine to electric drive motors. Electric motors uses a high voltage system requiring the development of resources and components to shield the system. Therefore, in this study, we analyze electromagnetic interference (EMI) shielding effectiveness (SE) characteristics of an auto crash pad according to the ratio of electrically conductive materials and propylene. In order to combine good mechanical characteristics and electromagnetic shielding of the automotive crash pad, metal-coated glass fiber (MGF) manufacturing methods are introduced and compared with powder-type methods. Through this study, among MGF methods, we suggest that the chopping method is the most effective shielding method.

전자차폐(電磁遮蔽)를 위한 크롬 및 알루미늄 스퍼터링의 효과 (Effects of Cr and Al Sputtered sheet for the Electromagnetic Shielding)

  • 김동진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.73-79
    • /
    • 2001
  • In this paper, shielding effectiveness(SE) of the shielding material of electromagnetic(EM) waves was investigated with actual experiments. The materials used in this study were made up of sputtering, film and powder of conductive materials - Cr, Al, Ag and Cu etc. Also, the polyester film was used as a base material. The experiment was carried out by using a shielding evaluator(Shielding box) TR17302 with an ADVANTEST spectrum analyzer, model R3361C. It was found from the experimental results that silver, copper, aluminum and chromium were good candidates as a shielding material against the EM waves with increasing the SE as the composite was laminated. The characteristics of the SE against the EM waves depended on a mode of preparation of specimen. The effects of density of particles on the SE were studied when the sputtering. The SE strongly depended on the electric resistance by density of sputtering and painting particles. SE increased as the density of particles was increasing.

  • PDF

전기로산화슬래그를 활용한 콘크리트의 차폐효과 측정 방법의 유효성 검증 연구 (A Study on Validation of the Shielding Effectiveness Measurement Method of the Concrete Containing Electric Arc Furnace Oxidizing Slag)

  • 장홍제;이한희;최효식;송태승;조원서
    • 한국건설순환자원학회논문집
    • /
    • 제9권4호
    • /
    • pp.478-482
    • /
    • 2021
  • 본 논문에서는 버려지는 전기로산화슬래그를 재활용하여 차폐용 콘크리트를 제작하는데 있어 필요한 차폐효과 측정방법에 대하여 연구하였다. 차폐용 콘크리트 블록의 전자파 차폐효과를 측정하기 위한 시스템의 결과와 실제 콘크리트로 구축된 건축물의 차폐효과를 비교하여, 소형화된 콘크리트 블록의 전자파 차폐효과 측정 시스템의 유효성을 검증하였다. 콘크리트 건축물의 크기는 2.9 × 2.9 × 3.4m이고 콘크리트 블록은 0.3 × 0.3 × 0.2m로 차폐효과 측정 방법은 MIL-STD-188-125-1을 준용하였다. 비교하여 위하여 사용되는 주파수 대역은 600MHz - 2GHz이고 비교되는 콘크리트의 구성은 일반적인 콘크리트와 전기로산화슬래그가 포함된 콘크리트이다. 콘크리트 구조물의 경우에는 구조적 안전성을 위하여 철근이 15cm 간격으로 설치되어 있지만, 철근의 전자파 특성을 주파수가 증가할수록 차폐효과 특성이 점점 감소하기에 두 비교대상의 측정결과에서 약간의 차이가 발생하였다. 결론적으로는 콘크리트 블록을 통한 차폐효과 측정결과는 건축물을 만들었을 때의 결과와 유사하여, 전자파 엔지니어링 설계에 충분히 활용할 수 있을 것으로 생각되고 표준시편을 활용한 콘크리트의 차폐효과 측정 시스템이 유효함을 검증하였다.

방호 시설 크기에 따른 전계강도 및 차폐 효과 비교 (Electric Field Strength and Shielding Effectiveness Comparison According to the Size of Shielding Facility)

  • 강호재;허창수;방정주;최진수;박우철
    • 한국전기전자재료학회논문지
    • /
    • 제27권4호
    • /
    • pp.221-225
    • /
    • 2014
  • In modern times, threat of high power electromagnetic wave is increasing. When the electrical grid and communication network are attacked by these high power electromagnetic wave, the whole infrastructure is paralyzed. To protect the infrastructure from these high power electromagnetic wave threat, the shielding facility that can block high power electromagnetic wave is constructed. Also shielding effectiveness evaluation about the constructed facility is important. But, because of space efficiency and saving of construction cost to construct the actual shielding facility, the shielding room wall is generally adjacent to exterior concrete structures. As space between shielding facility wall and concrete structures is very small, arranging the transmitting antenna exterior shielding facility is realistically difficult. Therefore, in this research, The shielding effectiveness measurement plan in the state of exterior narrow space of HEMP shielding facility is presented. And to apply this plan, The influence of shielding effectiveness according to the size of the shielding facility is analyzed.

전자파의 집중도를 이용한 바이모달 트램의 전자파 차폐 성능 분석 (Analysis of Electromagnetic Shielding Performance for a BiMODAL Tram using an Electromagnetic Concentration Index)

  • 최낙선;정기우;김남경;송명곤;이강원;목재균;김동훈
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1378-1384
    • /
    • 2011
  • In this paper, the electromagnetic shielding performance of a BiMODAL Tram is investigated by means of an electromagnetic analysis tool, called HFSS. For the purposed of doing this, first, three-dimensional finite element modeling for the tram including electronic devices and engine room is carried out. Then, for quantitatively assessing the electromagnetic shielding performance of the tram's body, concentration indexes for electric field magnitude and time-average stored electric energy are introduced. From numerical results, it is inferred that the tram's body can protect the electronic devices and engine room against external electromagnetic waves from 30 MHz to 100 MHz.

Discontinuous finite-element quadrature sets based on icosahedron for the discrete ordinates method

  • Dai, Ni;Zhang, Bin;Chen, Yixue
    • Nuclear Engineering and Technology
    • /
    • 제52권6호
    • /
    • pp.1137-1147
    • /
    • 2020
  • The discrete ordinates method (SN) is one of the major shielding calculation method, which is suitable for solving deep-penetration transport problems. Our objective is to explore the available quadrature sets and to improve the accuracy in shielding problems involving strong anisotropy. The linear discontinuous finite-element (LDFE) quadrature sets based on the icosahedron (in short, ICLDFE quadrature sets) are developed by defining projected points on the surfaces of the icosahedron. Weights are then introduced in the integration of the discontinuous finite-element basis functions in the relevant angular regions. The multivariate secant method is used to optimize the discrete directions and their corresponding weights. The numerical integration of polynomials in the direction cosines and the Kobayashi benchmark are used to analyze and verify the properties of these new quadrature sets. Results show that the ICLDFE quadrature sets can exactly integrate the zero-order and first-order of the spherical harmonic functions over one-twentieth of the spherical surface. As for the Kobayashi benchmark problem, the maximum relative error between the fifth-order ICLDFE quadrature sets and references is only -0.55%. The ICLDFE quadrature sets provide better integration precision of the spherical harmonic functions in local discrete angle domains and higher accuracy for simple shielding problems.

대용량 무선전력전송 환경 유도현상 감쇄를 위한 차폐 특성 분석 (Analysis of Shielding Characteristics for Induction Phenomenon Attenuation of Large Capacity Wireless Power Transmission Environment)

  • 채동주;김영석;정진수;임현성;조성구;홍성준
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1844-1851
    • /
    • 2017
  • As the capacity of the wireless power transmission increases, a higher supply current which may induce current in nearby conductive parts requires. Induced current may affect electric shock to the human body and malfunction of the electrical equipment. In order to prevent such induced phenomena as a risk factor, shielding is required between the source of the wireless power transmission and the conductive parts. The resonance frequency for the large capacity wireless power transmission has the wavelength of several hundred meters, so most environments are included in the near-field area. By wave impedance, the electric field has higher density in the near-field area and needs to be analyze for protecting. For this purpose, it is necessary to select a substance having a larger electric conductivity and optimized shielding structure. In this paper, an aluminum base shielding structure was presented to conduct experiments on thickness, position, and heat dissipation. In the 35 kW, 60 kHz environments, the optimized 5T Al base shielding structure attenuates the induced current to 43 %.

박판 자성 재료를 이용한 전력 케이블 인근의 자기장 차폐 (Magnetic Shielding with Thin Magnetic Materials near Power Cables)

  • 김상범;소준영;신구용;정진혜;명성호
    • 한국전자파학회논문지
    • /
    • 제20권7호
    • /
    • pp.639-647
    • /
    • 2009
  • 본 연구에서는 자기장 차폐를 위하여 3상 전력 케이블을 얇은 자성 판재로 둘러싸는 방법을 제안한다. 두꺼운 상용 뮤-메탈, 방향성 및 무방향성 규소 강판을 출발 재료로 하여 두께 0.1 mm의 차폐재 3종류를 제조하였다. 3상 전류일 때, 차폐재 위치의 자기장이 100 ${\mu}T$ 정도이면 뮤-메탈이 (SF<0.1) 가장 효과적이었고, 500 ${\mu}T$ 이상 이면 규소 강판이 (SF 0.3${\sim}$0.4) 더 효과적이었다. 또한, 안쪽에 방향성 규소 강판, 바깥쪽에 뮤-메탈을 함께 둘러쌀 경우 500 ${\mu}T$까지도 SF 를 0.1 이하로 할 수 있었다. 한편, 단상 전류에서는 고 투자율 소재의 적용은 오히려 자기장을 증가시키는 결과를 보였다. 이상의 결과는 자기장 강도 H의 크기에 따라 각 소재의 투자율 우열이 서로 다른 점과 이로 인해 차폐재 내에 유도되는 자기장 벡터와 원래의 자기장 벡터의 상호 상쇄 및 중첩 작용으로 설명할 수 있었다.

도전성(導電性) 분체(粉體)의 전자차폐(電磁遮蔽)에 관한 연구(硏究) (A Study on the Electromagnetic Shielding of Conductive Powder)

  • 김동진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.244-249
    • /
    • 2004
  • In this paper, shielding effectiveness(SE) of the shielding paint of electromagnetic(EM) waves was investigated with actual experiments. The shielding paint used in this study were made of powder of conductive materials - Ag, Cu, Al, Sn, Ni. Cr, Graphite and Charcoal etc. with a solubility in oil and water. Also, the paper was used as a base sheet. The experiment was carried out by using a shielding evaluator(Shielding box) TR17302 with an ADVANTEST spectrum analyzer, model R3361C. It was found from the experimental results that silver, copper, nickel were good candidates as a shielding material against the EM waves with increasing the SE as the composite was laminated. The characteristics of the SE against the EM waves depended on a mode of preparation of specimen. The effects of density of particles on the SE were studied about the EM shielding paint. The SE strongly depended on the electric resistance by density of painting particles. SE increased as the density of particles was increasing.

  • PDF