• Title/Summary/Keyword: Electric pump

Search Result 375, Processing Time 0.027 seconds

A Study of Bubble Pump that is applied Solar Heating Water System (태양열 온수 시스템에 적용한 기포펌프의 동작특성에 관한 연구)

  • Park, G.T.;Song, L.;Shim, K.J.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.32-37
    • /
    • 2007
  • Regarding the need of energy in advance and the depletion of fossil fuel energy, all researches around the world now are trying to extract energy from many alternative sources especially the renewable one. Solar, ocean tidal, wind and geothermal energy are renewable energy fields which many researches are focused on. This paper explains about effort to replace electric pump used in solar water heating system by bubble pump. The utilization of bubble pump in this system is very efficient since it needs heat energy for its operation that can be obtained easily. In addition, it can also simplify the construction of the system. Bubble pump also functions as a controller to circulate water inside the system. Before the installation of bubble pump, the special quality and performance of bubble pump should be analyzed. The result got from the analysis could show the fluctuation of water flow rate occurred because it sensitively reacts to the heat quantity. Here the heat quantity is taken from the solar that, as we know, is not stable in a whole day. Problems often occurred are the flow rate in this system is very low moreover it could be stop if the pressure exceeds the limit.

  • PDF

Economic Analysis of Heat Pump System through Actual Operation (교육 시설에서의 히트 펌프 냉난방 시스템 실사용을 통한 경제성 분석)

  • Kim, Gil-Tae;Cheong, Seong-Ir;Joo, Ho-Young;Ahn, Young-Chull;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.6
    • /
    • pp.470-475
    • /
    • 2007
  • The present study has been conducted economic analysis through actual operation of electric heat pump (EHP) and gas engine driven heat pump (GHP) which are installed at the same building in the university. Cost items, such as initial cost, annual energy cost and maintenance cost of each system are considered to analyze life cycle cost (LCC) and economical efficiencies are compared. The initial cost is considered on the basis of actual cost, and annual energy cost is converted into the cost after measuring electricity and gas consumption a day LCC applied present value method is used to assess economical profit of both of them. Variables used to LCC analysis are electricity cost escalation rate, natural gas cost escalation rate, interest rate, and service lives when each of them are 4%, 2%, 8%, and 20 years. The result shows that EHP (148,257,306 won) is more profitable than GHP (161,239,296 won) by 8.05% (12,981,990 won).

Experimental Study of Energy-Saving Realized with the Improvement of Inner Roughness in Double-Entry Centrifugal Pump (양흡입 원심펌프의 내부 표면 거칠기 개선에 따른 에너지 절감 실험 연구)

  • Lim, Sung-Eun;Sohn, Chang-Hyun;Ryu, Jung-Yup
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.6
    • /
    • pp.409-415
    • /
    • 2016
  • In this study, we test the effects of the surface roughness on the hydro efficiency of double-suction centrifugal pumps ($Q=70.7m^3/min$, H = 87 m). The original surface of the impeller and inner casing were coated, resulting in surface-roughness reductions ranging from $100{\sim}110{\mu}m$ to $0{\sim}0.08{\mu}m$. We conducted experimental studies to measure the efficiency of the pumps and operating-pump electro energy variations with different surface roughness values. The experimental results showed that the efficiency of the pumps increased by about 0.8~1.79% and the electric energy of the operating pump was reduced by around 4.38 ~ 6.08%. These results indicate that the performance of the pumps depend largely on the surface roughness of the impeller and inner casing, and by reducing the surface roughness, we can improve the efficiency of the pump and reduce costs by reducing the electric energy consumption.

Effect of Radius of Curvature of a Corona Needle on Ionic Wind Generation (방전 침전극의 곡률반경이 이온풍 발생에 미치는 영향)

  • Hwang, Deok-Hyun;Moon, Jae-Duk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.604-608
    • /
    • 2010
  • An electric fan for cooling high density electronic devices is limited and operated in very low efficiency. The corona discharge is utilized as the driving mechanism for an ionic gas pump, which allows for air flow control and generation with low noise and no moving parts. These ideal characteristics of ionic pump give rise to variety applications. However, all of these applications would benefit from maximizing the flow velocities and yields of the ionic pump. In this study, a needle-mesh type ionic pump has been investigated by focusing on the radius of curvature of corona needle points elevating the ionic wind velocity and efficiency. It is found that the radius of curvature of the corona discharge needle point influences significantly to produce the ionic wind and efficiency. As a result, an elevated ionic wind velocity and increased ionic wind generation yield can be obtained by optimized the radius of curvature of the corona needle electrode.

TECHNICAL INNOVATION OF FARM WELL PUMP

  • Zhang, Shaokang;Dang, Yongliang
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.217-226
    • /
    • 1993
  • As results of not selecting and using farm well pump properly , it's running regime is far away from high efficient zone and running efficiency of farm well pump is lower. The paper analyses unhealthy tendencies of technical state of diving-electric pump, deep well and centrifugal pump which are commonly used in our country. The paper also summarizes several technical innovation plans to raise efficiency : stage change plan, diameter change plan, speed change plan and synthetic technical innovation . Each plan gives a detailed introduction of designing and construction manners, through practical measuring , the synthetic efficiency of innovated well pumps raise above 30 percent. Economic benefit is evident.

  • PDF

Reynolds Number Effect on Regenerative Pump Performance in Low Reynolds Number Range

  • Horiguchi, Hironori;Yumiba, Daisuke;Tsujimoto, Yoshinobu;Sakagami, Masaaki;Tanaka, Shigeo
    • International Journal of Fluid Machinery and Systems
    • /
    • v.1 no.1
    • /
    • pp.101-108
    • /
    • 2008
  • The effect of Reynolds number on the performance of a regenerative pump was examined in a low Reynolds number range in experiment. The head of the regenerative pump increased at low flow rates and decreased at high flow rates as the Reynolds number decreased. The computation of the internal flow was made to clarify the cause of the Reynolds number effect. At low flow rates, the head is decreased with increasing the Reynolds number due to the decrease of the shear force exerted by the impeller caused by the increase of leakage and hence local flow rate. At higher flow rates, the head is increased with increasing the Reynolds number with decreased loss at the inlet and outlet as well as the decreased shear stress on the casing wall.

Critical Speed Analysis of a Vertical Pump (펌프회전체의 임계속도해석)

  • 전오성;김정태;임병덕
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.16 no.5
    • /
    • pp.50-59
    • /
    • 1992
  • A critical speed analysis of a pump shaft has been investigated. Among various methods in the shaft critical speed calculation, a transfer matrix method has been examined in this research. After a brief review on the transfer matrix method, a modeling procedure for a continuous structure has been discussed. Then, a critical speed of a multistage pump shaft has been estimated up to several low modes. Throughout an analysis, parametric effects on the bearing stiffness, a degree of the modeling order, and attachmant of the impeller have been investigated. As an application example, a critical speed analysis of a verical pump which has been implemented in domestic electric power plants for cooling water circulation has been conducted in order to provide a safe operation as far as a pump vibration is concerned.

  • PDF

Optimal Flow Design of High-Efficiency, Cold-Flow, and Large-size Heat Pump Dryer (히트펌프를 이용한 고효율 냉풍 대형 건조기 유동 최적설계)

  • Park, Sang-Jun;Lee, Young-Lim
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.5
    • /
    • pp.547-552
    • /
    • 2011
  • Drying process, corresponding to a final process in the area of food engineering, requires a lot of heat energy. Thus, the energy efficiency is very important for dryers. Since the energy efficiency of heat pump dryers is much higher compared to that of electric dryers or other types of dryers, most of large-capacity dryers are adopting heat pump. In this study, shapes, positions and number of air-circulating fans, guide vanes, air inlet, outlet and top separator were varied for optimization of the flow of a large-capacity heat pump dryer. In addition, fans were modelled with performance curves and porous media were assumed for foods and heat exchangers. The simulation results were applied to the 12-ton dryer and the velocity distributions were experimentally examined. Finally, uniform drying in time was successfully accomplished through frozen pepper experiment.

Hydraulic Force and Impeller Evaluation of a Centrifugal Heart Pump

  • Timms, D.L;Tan, A.C.C;Pearcy, M-J;Mcneil, K;Galbraith, A
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.376-381
    • /
    • 2004
  • A rig was constructed to test the performance characteristics and compare the hydraulic forces exerted on a centrifugal type artificial heart impeller. A conventional shaft. seal and bearing system. while driven by a small electric motor. supported the impeller which was separated from the pump casing by a six degree of freedom force transducer (JR3 Ine). Radial (x. y) and axial (z) hydraulic forces were recorded and compared. At physiological operating conditions. the results indicate that the double entry/exit centrifugal pump encounters a smaller radial force and significantly reduced axial thrust. These experimental results are valuable in the design of a magnetic bearing system to suspend the impeller of a centrifugal artificial heart pump. This experimental technique may also be applied to evaluate the required capacity and predict the lifetime of contact bearings in marine pumps.

Design of Magnetic Fluid Linear Pump (자성유체를 이용한 Linear Pump의 설계와 제작)

  • Park, Gwan-Soo;Park, Sang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.37-39
    • /
    • 1999
  • In this paper, the magnetic fluid linear pump is designed. Inside the small tube, magnetic fluid is shielded with thin rubber protector. The magnetic fluid activated by traveling pulses of magnetic field drags the water inside the pump. The iterative algorithm for the shape of magnetic fluid is presented by using nonlinear finite element method and Navier-Stokes equations. The computed curvature of fluid under the magnetic field and the gravitational force is agreed well with photograph image. The dimension and electric configurations of the magnetic linear pump are optimized and the results are compared with measurements.

  • PDF