• 제목/요약/키워드: Electric pump

검색결과 375건 처리시간 0.031초

Driving Mechanism of Tapered Pistons in Bent-Axis Design Axial Piston Pumps

  • Kim, Jong-Ki;Jung, Jae-Youn
    • Journal of Mechanical Science and Technology
    • /
    • 제17권2호
    • /
    • pp.181-186
    • /
    • 2003
  • In order to assure the quality of the bent axis design axial piston pumps driven by tapered pistons, it is necessary to know the characteristics of force applied to tapered pistons and the mechanism for driving the tapered pistons. Since they are able to perform both reciprocating and spinning motions in cylinder block, it is difficult to understand the driving mechanismand-tomeasure the forces applied to tapered pistons experimentally In the present study, the theoretical mechanism for driving the tapered pistons is studied by use of the geometric method. The driving area of the tapered pistons is measured by measuring the strain of a cylinder forced against a tapered piston using an electric strain gauge and a slip ring. The forces applied to tapered pistons is also investigated with the change of discharge pressure and the rotational speed. As a results of this investigation, it is concluded that the cylinder block is driven by one tapered piston in a limited area and the driving area is changed due to space angle of the tapered pistons and the swivel angle of the cylinder block. It is also observed that the force applied to tapered pistons increases as the discharge pressure and the rotational speed increase.

양어장 자동화 시스템의 개발 -1. 모형 수조를 중심으로- (The Development of an Automatic Aquaculture System -1. Using a model tank-)

  • 강호원;이성호;김제윤;정석권;김상봉
    • 한국수산과학회지
    • /
    • 제28권3호
    • /
    • pp.294-300
    • /
    • 1995
  • In aquaculture industrial field, an automatic management and control system is needed to cope with the difficulties such as expensive wage, ripe age of management worker and risk according to the unexpected change of environmental conditions in the aquarium. This paper introduces an automatic aquarium monitoring and control system. The system is developed using PC single board computer. A PC can be connected to multi-single hoard computers, and the communication between PC and single board computers is based on RS-422/485 interfacing method. The physical data of pH, DO, temperature and water level etc. are real-timely treated in the single board computer though individual transducers, transfered to the main monitoring PC through RS-422/485 communication, and those data are graphically shown on the PC monitor. Furthermore, the environmental circumstance can be monitored through the image processing system, and the emergency system can be operated under the condition of environmental incident such as electric power stoppage, DO deficiency, pump shut down and low level water etc.

  • PDF

압전 마이크로펌프 방식의 휴대용 약물전달장치 개발 (Development of the Portable Drug Delivery Systems with a Piezoelectric Micropump)

  • 김세윤;김영태;서현배
    • 드라이브 ㆍ 컨트롤
    • /
    • 제12권4호
    • /
    • pp.71-76
    • /
    • 2015
  • The therapy of injecting a fixed amount of a prescribed drug for a predetermined time is an effective treatment in relieving pain during anticancer treatments. Due to recent medical technology development, cancer is currently classified as a disease that can be managed in the patient's lifetime. If patients were able to use a drug delivery system that was portable, sustainable and had an accurate flow control, they would be able to inject medication whenever they need. In this study we developed a piezoelectric micropump for a drug delivery system by designing a pump chamber, check valve and diaphragm. We also developed a driving circuit that consumes low power and to which we applied a variety of signals. We fabricated a portable drug delivery system with this piezoelectric micropump and driving circuit. In addition, through a performance test, we confirmed that the system can precisely control the drug flow rate.

의령수역의 자동화 물관리 시스템 운영개선연구 (A study on Improvement of Automatic Water Management System in Uiryeong Watershed Area)

  • 조영제;이명준;김영호;박상현
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.213-214
    • /
    • 2005
  • Uiryung Watershed area, located at the confluence of Nam River and Nagdong River has 9000 ha of agricultural land area and 3024 ha of paddy rice field have been reclaimed and managed by Korean Agricultural and Rural Infrastructure Corporation(KARICO) in the riparian area since 1954. In spite of irrigation and drainage improvement projects in last 3 decades since 1970, there are severe drought and innundation problems in the area. To improve the difficulties and efficient usage of irrigation water not only for agriculture but also for environmental conservation and cultural ceremony, Automatic Water management system has been installed supported by Ministry of Agriculture and Fishery in Korean Government. The control office in Uiryung Branch Office of KARICO, receive all the water management records from Remote Terminal Units in 7 reservoirs and 26 Pump stations to operate the decision supporting system of irrigation and drainage facility during cropping period. Since the completion of the water management system at the end of 2003, the electric cost decrease in 80 % than average years. In spite of decrease of two technical assistants since 2004, complains from farmers for the water management are very rare. The technological experience from the automatic water management system would contribute not only for the efficient water management of Uiryang area but also for the modernization of water management of other watershed areas in the future.

  • PDF

Syringe Infusion-based Contactless Atmospheric Pressure Ionization Mass Spectrometry for Small and Large Biomolecules

  • Lo, Ta-Ju;Chang, Chia-Hsien;Chen, Yu-Chie
    • Mass Spectrometry Letters
    • /
    • 제3권4호
    • /
    • pp.87-92
    • /
    • 2012
  • In this study, we explored a new approach for generating ions of organics and biomolecules using contactless atmospheric pressure ionization (C-API). That is, a tapered capillary (~20 cm) was connected to a syringe, which was coupled to a syringe pump for providing a given flow rate to introduce sample solution to the proximity of a mass spectrometer. The gas phase ions derived from analytes were readily formed in the capillary outlet, which was very close to the mass spectrometer (~1 mm). No external electric connection was applied on the capillary emitter. This setup is very simple, but it can function as an ion source. This approach can be readily used for the analysis of small molecules such as amino acids and large molecules such as peptides and proteins. The limit of the detection of this approach was estimated to be ~10 pM when using bradykinin as the sample. Thus, we believe that this approach should be very useful for being used as an alternative ion source because of its low cost, high sensitivity, simplicity, and ease of operation.

3-way형과 Bypass형 서보유압 피에조 인젝터의 구동특성 비교 (Comparison Analysis of Dynamic Characteristics of Servo-hydraulic Piezo-driven Injector between 3-way and Bypass-circuit Type)

  • 조인수;정명철;이진욱
    • 한국자동차공학회논문집
    • /
    • 제21권5호
    • /
    • pp.169-175
    • /
    • 2013
  • CRDi technology of diesel engine was developed from in the early 2000s due to a need to increase fuel efficiency and environment care. Especially, high-pressure fuel injection system in CRDi system which has a fuel injection unit including an injector, a fuel pump and common-rail, etc. becomes possible to make the exhaust gas clean as well as power improvement. In this study, comparison of dynamic characteristics of servo-hydraulic piezo-driven injector with 3-way and bypass-circuit type was analyzed by using the AMESim code. As results of this study, it found the bypass-circuit inside servo-hydraulic piezo injector can cause a faster injection response than that of the 3-way type. Also it was shown that bypass-circuit type had better control capability due to hydraulic bypass system.

도서관의 공간사용 특성에 따른 냉난방설비 리모델링의 경제성 평가 (Energy Efficiency Evaluation of Heating and Cooling Systems as Space Program in Renovated Library)

  • 박강현;차정훈;김수민;박경원
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.205-211
    • /
    • 2012
  • Unlike the previous approaches, we analyzed for economic efficiency of renewed heating and cooling systems as the characteristics of space. The purpose of this study is to analysis the energy consumption and economical efficiency of absorption chillers and EHP systems in renovated library. It is important that equipment selection should be considering energy cost as well as space program. In recently, many EHP systems were installed in the building for reducing the energy cost and for seeking the convenience of individual control. In contrast, though absorption chillers have the disadvantage of a central control, absorption chillers are appropriate for the conditions of the library that needs simultaneous operation. The results by payback period method, show that selection of heating and cooling systems should be consider for space program and the characteristics of space.

신재생에너지설비 건물설치 의무화 및 인증제를 고려한 용량설계 방안 (Conceptual Design Strategy of Renewable Energy Application for Building Certification and Mandatory System)

  • 이경호;이동원;권혁민;이창준
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.99-104
    • /
    • 2011
  • This paper describes a design strategy at conceptual design stage using RETScreen software tool for building application of renewable energy resources. Currently, government and public buildings are required to adopt renewable energy systems with a minimum requirement for the amount of renewable energy supply. Meanwhile, there is a certificate program for private office buildings to enhance propagation of renewable energy systems. When considering application of renewable energy systems to a building, it is worthwhile developing a method to determine optimal design sizes of renewable energy systems. In the paper, a design strategy is introduced with a couple of case studies to determine optimal capacities of each renewable energy system in a building and suggest to use the method to evaluate the system for the building certificate program and the mandatory renewable target program. Objective functions considered in the study are initial system cost and reduction of CO2 emissions from the system. In the optimization study, it is assumed that solar thermal collectors are installed to satisfy solar fraction of 60%. Other renewable energy systems such as ground-source heat pump, solar PV and non-renewable systems such as electric chiller and gas-fired boiler are sized using an optimal sizing method with RETScreen suggested the authors previously.

  • PDF

A Study on the Control Characteristics of ER Valve-FHA System and Durability Test

  • Jang Sung-Cheol;Chang Tae-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1621-1631
    • /
    • 2005
  • In this paper, making the best use of the features of the electro-rheological (ER) valve, a two-port pressure control valve using ER fluids is proposed and manufactured. The ER-Valve characteristics are evaluated by changing the intensity of the electric field and the number of electrode. As only with electrical signal change to the ER-Valve in which ER fluid flowing, ER fluid flow is controlled, so development of simple ER-Valves have been tried. The ER-Valves and pressure drop check method are considered to be applied to the fluid power industry. Using the manufactured pressure control valve, a one-link manipulator with FHA (Flexible Hydraulic Actuator) is driven. As a result, it is experimentally confirmed that the pressure control valve using ER fluids is applicable to use in driving actuator. If it applies characteristics of the ER fluids, it will be able to apply in the control system for the ER Valve which occurs from industrial controller. After having durability test, shear stress increased regularly because of starch particles crushed by pump and particle size that was almost the same. Moreover, Ra of copper electrode increased about 1.56 times rather than before those of performing durability test, and Rz increased about 2.2 times.

LCC를 이용한 공조 방식별 비교 연구 (Comparison Study of Air-conditioning Systems using LCC Analysis)

  • 김종국;정광섭;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권3호
    • /
    • pp.12-18
    • /
    • 2012
  • The purpose of this study is to make an economic analysis(Life cycle cost) of selecting optimal air conditioning system for a research building which is 8 stories with a total floor area of $32,010m^2$. Energy consumptions of three proposed air-conditioning systems(Alt-1,2,3) that reflect the government green-growth policy are calculated and compared. The results show that life cycle cost of Alt-3(Ventilation DX AHU+EHP) is less than Alt-1(EHP+ventilation DX AHU) by 5.1%, and Alt-2(Absorption chiller/heater+EHP) by 34.3%. Annual energy consumption of Alt-3 is less than Alt-1 by 9.9%, and Alt-2 by 37.4%. Annual $CO_2$ emission of Alt-3 is less than Alt-1 by 9.9%, and Alt-2 by 0.2%.