• 제목/요약/키워드: Electric pump

검색결과 375건 처리시간 0.024초

수직형 저널 베어링에서 preload 변화에 따른 베어링 패드 온도 변화 (Bearing Pad Temperature Change Depending on the Preload of Vertical Journal Guide Bearing)

  • 김준성;김두영;김동관;박상호
    • 한국유체기계학회 논문집
    • /
    • 제12권6호
    • /
    • pp.33-40
    • /
    • 2009
  • The temperature of vertical pump bearing metal in the pumped storage power plant has been high enough to shutdown the unit. Attempts such as decreasing the oil supply temperature, increasing the bearing oil gap etc. were performed to resolve the problem, but the issue was not resolved. Finally, the high bearing metal temperature was corrected by adjusting the bearing preload. The preload is formed by the oil wedge between the journal surface and bearing pad surface and the degree of preload is determined by the machined radial clearance, assembled radial clearance, rotor journal diameter etc. This paper focuses on the analysis of the preload depending on the bearing parameters and the result of the modification of the bearing following the analysis. The bearing metal temperature dropped as much as $20^{\circ}C$ which was similar as expected by software calculation. But the shaft vibration could increase when the assembled radial clearance is excessive. So, the adjustment of the bearing preload for the tilting pad type journal bearing should be carefully performed.

풀형 고속증식로의 과도 현상을 모사하는 Fast Running System Code개발 (Fast Running System Code Development to Simulate Transient Behavior of Pool-Type LMFBRs)

  • Youg Bum Lee;Soon Heung Chang;Mann Cho
    • Nuclear Engineering and Technology
    • /
    • 제17권1호
    • /
    • pp.16-24
    • /
    • 1985
  • 풀형 고속증식로에서의 과도 현상을 모사할 수 있는 전산 모델이 개발되었다. 이 전산 모델 SIM-FARP는 어떠한 펌프로의 전원 상실사고나 완전한 강제냉각 상실사고, 그리고 자연순환 과정 등을 모사할 수 있는 Fast Running Computer Code이다. 이에 따라 8개의 지배방정식이 유도되었으며, 이8개의 미분 방정식을 풀기 위해 Runge-Kutta의 수치해석방법이 사용되었다. 개발된 전산 프로그램은 두 가지 예제에 적용되었는데 이는 Super-Phenix-I에서의 펌프에의 전원상실사고 및 원자로가 정지되지 않는 상태에서의 외부전원 상실사고이다.

  • PDF

부항 장치용 압력 제어 밸브 개발 (Developing a Pressure Control Valve for Air Extraction Cupping Device)

  • 이재용;심동욱;안수광;김은석;이병렬;양기영
    • Korean Journal of Acupuncture
    • /
    • 제38권4호
    • /
    • pp.308-316
    • /
    • 2021
  • Objectives : This study aimed to develop a cupping pressure control valve for limiting maximum negative pressure while achieving clinical therapeutic outcomes to minimize side effects induced by excessive negative pressure of air extraction cupping devices. Methods : To determine the clinical necessity and suitability of the cupping pressure control valve, this study was designed to measure the change in pressure with or without the valve using both a manual and an electric suction pump. Results : While the maximum pressure was limited by the pressure control valve, the pressure did not increase above a certain level regardless of the type of manual or electric pump. Conclusions : This study will contribute to the development of a safer and more effective base technology for cupping treatment in oriental medicine.

A Feasibility Study on Adopting Sliding Pressure Operation for Drum Type Boiler

  • Baek, SeHyun;Kim, HyunHee;Park, SangBin;Kim, YoungJoo;Park, Hoyoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권3호
    • /
    • pp.403-407
    • /
    • 2016
  • In general, drum-type boilers are designed for base load duty and applied under constant pressure operation mode. Recently, however conditions often occur that even drum-type boilers have to operate at partial load conditions. A feasibility study on adopting the sliding pressure operation for drum-type boiler was conducted, and corresponding performance changes and effects on the equipment were analyzed by utilizing a process simulation model. As a result, the conclusion was reached that drum type boilers are able to adopt the sliding pressure operation and can improve of net efficiency at part load operation in spite of the Rankine cycle efficiency reduction due to the decreases in main steam pressure. Because of thank to improvement of high pressure turbine stage-1 internal efficiency and power savings of boiler feed water pump. The sliding pressure operation is advantageous in terms of stress level relief for boiler tube as well as maintaining the rating steam temperature at part load condition. However, cautions are required because the drum boilers have poor dynamic response characteristics which may get worse during the sliding pressure operation.

대형 상용차량 하이브리드 전동식 조향 시스템 주행 성능평가를 위한 HILS 시스템 개발 (Development of HILS System for Performance Evaluation of a Heavy Commercial Vehicle Hybrid Electric Power Steering System)

  • 유춘식;최규재
    • 한국자동차공학회논문집
    • /
    • 제25권1호
    • /
    • pp.103-110
    • /
    • 2017
  • Most commercial vehicles have adopted the hydraulic power steering system. To reduce fuel consumption and to improve steering controllability, a hybrid electric power steering system is being developed for commercial vehicles. In this study, the HILS (Hardware In the Loop Simulation) system equipped with a commercial vehicle hybrid electric power steering system was developed and the vehicle dynamic performance of a truck with the steering system was evaluated. The hybrid electric power steering system is composed of the EHPS motor pump, column mounted EPS system, and ball nut steering gear box for heavy commercial vehicles. The accuracy of vehicle models equipped with the HILS system was verified with comparisons between the simulation results and field test results. The road reaction forces of the steering system were generated from the vehicle model and verified using field test results. Step steering tests using the verified HILS system were carried out and the performance of a newly developed commercial vehicle hybrid electric power steering system was evaluated.

지열히트펌프 활용을 통한 전력계통 부하율 향상 및 CO2 감축 (CO2 emission Reduction and Load factor improvement of Power Systems, using Geothermal Source Heat Pump)

  • 이건우;이상중;양성덕
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.349-354
    • /
    • 2008
  • 2008년 8월 우리나라는 온실효과로 인한 기후변화 대응 역량을 강화하고, 에너지의 안정적 공급과 효율화 체계를 구축하기 위한 방안으로 '제1차 국가에너지기본계획'을 발표하였다. 이에 따르면 우리나라는 세계 10위의 에너지다소비 국가이자, 그 중 97% 이상을 해외 수입에 의존하는 나라로서 신재생에너지설비의 중요성이 크게 부각되고 있다. 본 논문은 일반적인 건물의 난방설비로 이용되고 있는 가스와 유류설비를 지열히트펌프로 대체함으로서, 전력계통의 부하율을 향상시키는 방안을 제시하였으며, 이에 따른 에너지비용 절감과 온실가스의 감축방안을 정량적으로 제시하였다.

  • PDF

단위 인버터 병렬운전에 의한 발전소 해수펌크 적용 (Studies on the Application of Unit-inverter Parallel Operation to Sea-water Lift Pump in Power Plant)

  • 김수열;류홍우
    • 전력전자학회논문지
    • /
    • 제3권1호
    • /
    • pp.1-7
    • /
    • 1998
  • 발전설비의 대형화로 인하여 전력절감 문제가 크게 대두되었고, 팬이나 펌프를 부하 변화에 따라 속도제어하므로써 전기 에너지를 절약 할 수 있다. 1MVA급 단위 인버터 2대를 병렬 운전하여 대용량 2MVA GTO 인버터를 구현하였으며, 단위 인버터의 병렬 운전은 2대의 출력변압기 2차측 결선을 직렬 연결하여 구현하였다. 개발된 시스템은 제어반, 정류기반, 2대의 인버터반으로 구성되어 있으며, 이 시스템은 한국전력공사 성인천복합화력발전처 해수펌프 구동 유도전동기(6.6KV 1500KW)에 적용되어 전력절감에 기여하고 있다. 또 단위 인버터가 상호 180$^{\circ}$위상차를 갖도록 병렬 운전하므로써 고조파 성분을 저감시키면서 대용량을 구현하였다.

Effect of multiple-failure events on accident management strategy for CANDU-6 reactors

  • YU, Seon Oh;KIM, Manwoong
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3236-3246
    • /
    • 2021
  • Lessons learned from the Fukushima Daiichi nuclear power plant accident directed that multiple failures should be considered more seriously rather than single failure in the licensing bases and safety cases because attempts to take accident management measures could be unsuccessful under the high radiation environment aggravated by multiple failures, such as complete loss of electric power, uncontrollable loss of coolant inventory, failure of essential safety function recovery. In the case of the complete loss of electric power called station blackout (SBO), if there is no mitigation action for recovering safety functions, the reactor core would be overheated, and severe fuel damage could be anticipated due to the failure of the active heat sink. In such a transient condition at CANDU-6 plants, the seal failure of the primary heat transport (PHT) pumps can facilitate a consequent increase in the fuel sheath temperature and eventually lead to degradation of the fuel integrity. Therefore, it is necessary to specify the regulatory guidelines for multiple failures on a licensing basis so that licensees should prepare the accident management measures to prevent or mitigate accident conditions. In order to explore the efficiency of implementing accident management strategies for CANDU-6 plants, this study proposed a realistic accident analysis approach on the SBO transient with multiple-failure sequences such as seal failure of PHT pumps without operator's recovery actions. In this regard, a comparative study for two PHT pump seal failure modes with and without coolant seal leakage was conducted using a best-estimate code to precisely investigate the behaviors of thermal-hydraulic parameters during transient conditions. Moreover, a sensitivity analysis for different PHT pump seal leakage rates was also carried out to examine the effect of leakage rate on the system responses. This study is expected to provide the technical bases to the accident management strategy for unmitigated transient conditions with multiple failures.

제주지역 지하공기를 이용한 농업시설용 히트펌프시스템의 난방 성능 분석 - 제주지역을 중심으로 - (The Analysis of heating performance of heat pump system for agricultural facility using underground air in Jeju area - Focused on the Jeju Area -)

  • 강연구;임태섭
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.109-114
    • /
    • 2016
  • Purpose: The underground air is the warm air discharged from the porous volcano bedrock 30-50m underground in Jeju, including excessive humidity. The temperature of the underground air is $15-20^{\circ}C$ throughout the year. In Jeju, the underground air was used for heating greenhouses by supplying into greenhouses directly. This heating method by supplying the underground air into greenhouses directly had several problems. The study was conducted to develop the heat pump system using underground air as heat source for resolving excessive humidity problem of the underground air, adopting the underground air as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) and saving heating cost for agricultural facilities. Method: 35kW scale(10 RT) heat pump system using underground air installed in a greenhouse of area $330m^2$ in Jeju-Special Self-Governing Province Agricultural Research & Extension Services, Seogwipo-si, Jeju. The inlet and outlet water temperature of the condenser, the evaporator and the thermal storage tank and the underground air temperature and the air temperature in the greenhouse were measured by T type thermocouples. The data were collected and saved in a data logger(MV200, Yokogawa, Japan). Flow rates of water flowing in the condenser, the evaporator and the thermal storage tank were measured by an ultrasonic flow meter(PT868, Panametrics, Norway). The total electric power that consumed by the system was measured by a wattmeter(CW240, Yokogawa, Japan). Heating COP, rejection heat of condenser, extraction heat of evaporator and heating cost were analyzed. Result: The underground air in Jeju was adopted as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) in 2010. From 2011, the heat pump systems using underground air as a heat source were installed in 12 farms(16.3ha) in Jeju.

지열을 이용한 학교시설의 냉·난방시스템 효율성분석 -에너지 소비량을 중심으로- (Efficiency Analysis of the HVAC system in the School Facilities Using the Geothermal Energy -Focused on the energy consumption-)

  • 박동순;이재림
    • 교육녹색환경연구
    • /
    • 제6권2호
    • /
    • pp.25-52
    • /
    • 2007
  • This paper is focused on the economical efficiency of the geothermal heat pump system in school. As the importance of problems of environment and energy becomes larger, the development and distribution of energy-saving technology in the whole nation has become influential. This paper is intended, targeting on school buildings scattered all over the country, to evaluate the introduction and possibility of a terrestrial heat system which is in the first stage of introduction in the country, through energy consumption and efficiency in case where a terrestrial heat system is introduced. To do that, the author performed a qualitative analysis of the heat pump system using various terrestrial heat energy and the system introduced to existing school buildings and, through the analysis, made tentative evaluation on the most environment-friendly and energy saving type system. Also, the author performed simulation analysis using a currently typical school building standard and, on the basis of this result, conducted efficiency analysis of various heat pump systems. The conclusion according to synthetical analysis & evaluation can be summarized as follows. In case a heat pump system is introduced to a school building, it was deemed the investment in the early stage would increase, but the investment could be collected within 5~6 years through reduction of large operation expenses. Also, it was analyzed in case of terrestrial heat contracted heat mode using midnight electric power among heat pump systems, not only early investment but also operation expenses could be reduced to a great extent. Accordingly in case the system using terrestrial heat energy is applied to the school buildings that are to be newly built or repaired in the future, it will provide an object-lesson to students as well as contributing to energy saving.

  • PDF