• Title/Summary/Keyword: Electric power system interconnection

검색결과 44건 처리시간 0.023초

Passivity-Based Control System of Permanent Magnet Synchronous Motors Based on Quasi-Z Source Matrix Converter

  • Cheng, Qiming;Wei, Lin
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1527-1535
    • /
    • 2019
  • Because of the shortcomings of the PID controllers and traditional drive systems of permanent magnet synchronous motors (PMSMs), a PMSM passivity-based control (PBC) drive system based on a quasi-Z source matrix converter (QZMC) is proposed in this paper. The traditional matrix converter is a buck converter with a maximum voltage transmission ratio of only 0.866, which limits the performance of the driven motor. Therefore, in this paper a quasi-Z source circuit is added to the input side of the two-stage matrix converter (TSMC) and its working principle has also been verified. In addition, the controller of the speed loop and current loop in the conventional vector control of a PMSM is a PID controller. The PID controller has the problem since its parameters are difficult to adjust and its anti-interference capability is limited. As a result, a port controlled dissipative Hamiltonian model (PCHD) of a PMSM is established. Thereafter a passivity-based controller based on the interconnection and damping assignment (IDA) of a QZMC-PMSM is designed, and the stability of the equilibrium point is theoretically verified. Simulation and experimental results show that the designed PBC control system of a PMSM based on a QZMC can make the PMSM run stably at the rated speed. In addition, the system has strong robustness, as well as good dynamic and static performances.

분산전원 연계선로에서 보호계전기의 상전류 오차보정 알고리즘 개발 (The Development of an Algorithm for the Correction of Errors in the Phase Current of the Protective Relay on Distribution System Interconnected with Distributed Generations)

  • 신동열;윤동현;차한주
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1604-1609
    • /
    • 2013
  • When the ground fault on the power side occurs on distribution system interconnected with distributed generations, the abnormal current is generated in the neutral conductor by the connection type and the iron core structure of transformers for the interconnection of distributed power supplies due to the unbalanced voltage of the system, and subsequently the false operation of the protective relay on the load side occurs. Herein, this paper proposes the method to correct errors in the phase current to prevent the false operation of the protective relay by applying p-q theory and presents the simulation result of the error correction algorithm using PSCAD/EMTDC.

풍력발전단지의 효율적인 운전을 위한 STATCOM 적용 가능성 연구 (A Study on the STATCOM Application for Efficient Operations of Wind Farm)

  • 장성일;최정환;박인기;황혜미;최돈만;김광호;유능수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권5호
    • /
    • pp.250-256
    • /
    • 2003
  • In this papur, the STATCOM (STATic synchronous COMpensator) application for efficient operations of wind farm is described. The wind farm connected with the electric power network is one of good alternative energy sources. However, it would be also highly possible that interconnection of wind farm causes unwanted influences on distribution system operation, protection and control. This paper proposes the STATCOM application for reducing the negative effects from interconnection of wind farm with distribution networks. The simulation results show that STATCOM would be on effective and useful device to resolve the bad influences from wind farm on distribution networks and improve the operational efficiency of wind farm. In the simulation, the radial distribution network of IEEE 13 bus was modeled using PSCAD/EMTDC.

고립지역의 풍력/디젤 복합발전 전력품질 특성 (The Power Quality about Wind/Diesel combined power generation in isolated area)

  • 고석환;김석우;이윤섭
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.245-249
    • /
    • 2009
  • Antarctic King Sejong Station was established in King George Island, the South Pole in 1988, and has been executing the monitoring studies on the change of antarctic natural environment. As an available power, the wind energy generator has been used in the form of hybrid with mainly diesel generator. Because the wind generation power sharply changes by wind energy, it must be careful during the system operation. When the power system becomes stable, the output performance of wind energy generator becomes stable. But, in case of unstable system, the errors frequently occur on the wind energy generator and it badly impacts the power system by output of wind energy generator. The purpose of this paper is to analyze suitability while operating the system of 10kW wind energy generator at Antarctic King Sejong Station, an isolated area, and to analyze the problem and improvements by power quality.

  • PDF

새로운 18-step 전압원 컨버터를 이용한 Back-to-Back 계통연계시스템 (Back-to-Back Interconnection System using New 18-step Voltage Source Converter)

  • 이혜연;이지헌;한병문;리위룽;김수열;장병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.62-64
    • /
    • 2008
  • 본 연구에서는 펄스다중화 보조회로론 이용한 18-step Back-to-Back 전압원 컨버터를 제안한다. 제안하는 Back--Back 전압원 컨버터는 교류연계점에서 유 무효전력의 독립적인 제어가 가능하다. 펄스수를 증가시키는 방법은 이론적인 접근을 통해 분석하였으며, 제안하는 시스템의 동작은 PSCAD/EMTDC 소프트웨어로 시뮬레이션 모델을 개발하여 확인하였고 실질적인 성능검증은 하드웨어 축소모형을 제작하고 실험을 통해 실시 하였다.

  • PDF

수도권 전압안정도 향상을 위한 100MVA STATCOM 위치선정 연구 (The Site Selection of 100MVA STATCOM for Voltage Stability Enhancement in Korean Metropolitan Area)

  • 장병훈;김수열;한정열;최돈근;송화창;이병준
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1543-1548
    • /
    • 2007
  • This paper reports a study on determination of the adequate location of 100 MVA STATCOM regarding the transfer capability enhancement on the metropolitan interface as well as the economy in system operation. The base case in the study was established considering a scenario of the energy support to North Korea from the KEPCO (Korea Electric Power Corporation) system through a HVDC interconnection. In the base case, the energy support was approximately modeled with a load of 1500 MW, and by the load addition, the system was weakened in terms of voltage stability and transfer capability. After a thorough investigation on the case, the location of the STATCOM was decided to compensate the reactive deficit of the modified system and to maximize the operational benefit which can be estimated by FV analysis.

조선대학교 기숙사 50kW 계통연계형 태양광발전시스템 효율 분석 (Analysis of Operating Efficiency for 50kW Utility Interactive Photovoltaic System in Chosun university)

  • 박정국;박정민;이강연;임홍우;조금배;백형래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1736-1738
    • /
    • 2005
  • This paper presents experimental operation with utility interactive 50kw photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for dormitory. The status of photovoltaic generation system components and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for dormitory.

  • PDF

태양광전원 계통연계시험장치에 의한 수용가 전력품질특성에 관한 연구 (Analysis of Customer Power Quality Characteristics Using PV Test Devices)

  • 김병목;김병기;박재범;노대석
    • 한국융합학회논문지
    • /
    • 제2권4호
    • /
    • pp.21-27
    • /
    • 2011
  • 현재 신 재생에너지 보급사업에 의해 설치되고 있는 태양광전원설비가 전력계통과 연계 운영될 경우 배전계통의 전력품질 요소에 어떠한 영향을 미치고 있는지를 모의시험을 통해 정확히 측정 분석하여 향후 분산형전원의 확대 보급에 따른 가이드라인의 구축과 기술적인 연계지침이 필요한 상황이다. 따라서 본 논문에서는 태양광이 연계되는 위치에 따른 선로임피던스($R{\pm}jX$)에 의하여 생기는 전압상승 및 하강에 의한 전력품질[Sag/Swell] 저하 현상에 대하여 태양광전원용 LabVIEW 프로그램을 통해 전력품질 시험을 수행하여 그 특성을 분석한다.

HVDC 변환소의 여유요소(Spare)를 고려한 사고확률 분석에 관한 연구 (A Study on Outage Probability Analysis of HVDC Converter Considering Spare Elements)

  • 오웅진;최재석;김찬기;윤용범
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1408-1414
    • /
    • 2018
  • Recently, as a solution to the problem of maintaining system reliability, stability, and quality occurring worldwide, such as activation of smart grid and recognition of super grid and rapid grid interconnection of renewable energy sources HVDC(High Voltage Direct Current) will appear on the front of the electric power system. These concepts are also very important concepts in HVDC systems. When the HVDC system is linked to the existing power system, it is composed of AC/DC/AC conversion device, and these conversion devices are composed of many thyristors. These parts(Devices) are connected in a complicated manner, and they belong to the one with a higher failure rate. However, the problem of establishing the concept of failure rate of HVDC parts directly linked to economic efficiency and the understanding accompanying it are still insufficient. Therefore, in this paper, we establish the meaning of reliability in power system and try to develop a model to analyze and verify the failure rate data of HVDC based on this.

Application of SFCL on Bus Tie for Parallel Operation of Power Main Transformers in a Fuel Cell Power Systems

  • Chai, Hui-Seok;Kang, Byoung-Wook;Kim, Jin-Seok;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2256-2261
    • /
    • 2015
  • In the power plant using high temperature fuel cells such as Molten Carbonate Fuel Cell(MCFC), and Solid Oxide Fuel Cell(SOFC), the generated electric power per area of power generation facilities is much higher than any other renewable energy sources. - High temperature fuel cell systems are capable of operating at MW rated power output. - It also has a feature that is short for length of the line for connecting the interior of the generation facilities. In normal condition, these points are advantages for voltage drops or power losses. However, in abnormal condition such as fault occurrence in electrical system, the fault currents are increased, because of the small impedance of the short length of power cable. Commonly, to minimize the thermal-mechanical stresses on the stack and increase the systems reliability, we divided the power plant configuration to several banks for parallel operation. However, when a fault occurs in the parallel operation system of power main transformer, the fault currents might exceed the interruption capacity of protective devices. In fact, although the internal voltage level of the fuel cell power plant is the voltage level of distribution systems, we should install the circuit breakers for transmission systems due to fault current. To resolve these problems, the SFCL has been studied as one of the noticeable devices. Therefore, we analyzed the effect of application of the SFCL on bus tie in a fuel cell power plants system using PSCAD/EMTDC.