• 제목/요약/키워드: Electric power grid

검색결과 725건 처리시간 0.025초

Smart Grid-The next Generation Electricity Grid with Power Flow Optimization and High Power Quality

  • Hu, Jiefeng;Zhu, Jianguo;Platt, Glenn
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.425-433
    • /
    • 2012
  • As the demand for electric power increases rapidly and the amount of fossil fuels decreases year by year, making use of renewable resources seem very necessary. However, due to the discontinuous nature of renewable resources and the hierarchical topology of existing grids, power quality and grid stability will deteriorate as more and more distributed generations (DGs) are connected to the grids. It is a good idea to combine local utilization, local consumption, energy storage and DGs to form a grid-friendly micro grid, these micro grids can then assembled into an intelligent power system - the smart Grid. It can optimize power flow and integrate power generation and consumption effectively. Most importantly, the power quality and grid stability can be improved greatly. This paper depicts how the smart grid addresses the current issues of a power system. It also figures out the key technologies and expectations of the smart grid.

Transient Characteristics and Physical Constraints of Grid-Tied Virtual Synchronous Machines

  • Yuan, Chang;Liu, Chang;Yang, Dan;Zhou, Ruibing;Tang, Niang
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1111-1126
    • /
    • 2018
  • In modern power systems, distributed generators (DGs) result in high stress on system frequency stability. Apart from the intermittent nature of DGs, most DGs do not contribute inertia or damping to systems. As a result, a new control method referred to as a virtual synchronous machine (VSM) has been proposed, which brought new characteristics to inverters such as synchronous machines (SM). DGs employing an energy storage system (ESS) provide inertia and damping through VSM control. Meanwhile, energy storage presents some physical constraints in the VSM implementation level. In this paper, a VSM mathematical model is built and analyzed. The dynamic responses of the output active power are presented when a step change in the frequency occurs. The influences of the inertia constant, damping factor and operating point on the ESS volume margins are investigated. In addition, physical constraints are proposed based on these analyses. The proposed physical constraints are simulated using PSCAD/EMTDC software and tested through RTDS experiment. Both simulation and RTDS test results verify the analysis.

스마트폰 기반의 지능형 태양광 전력적산 모니터링 시스템에 관한 연구 (The intelligent solar power monitoring system based on Smart Phone)

  • 김관형
    • 한국정보통신학회논문지
    • /
    • 제20권10호
    • /
    • pp.1949-1954
    • /
    • 2016
  • 스마트 그리드(smart grid) 기술은 전력 공급자와 소비자 사이를 실시간으로 전력정보를 교환함으로써 전력의 효율성을 높이는 전력망 관리 기술이다. 최근에는 유지보수 및 설치가 용이한 태양광 발전시스템에 대한 적용이 늘고 있다. 그러나 태양광 발전 시스템은 고장진단이 어려우며, PV(PhotoVoltaics) 어레이 및 인버터(inverter) 등의 결함과 기타 잠재적인 출력저하 요소로 인하여 발전량이 감소하기도 한다. 이처럼 태양광 발전 시스템을 통하여 안정적인 에너지 포집과 관리 및 조속한 고장 검출이 필수 요구사항이라 할 수 있다. 본 논문에서는 태양광 발전 시스템을 대상으로 전력 생산량 및 이상 동작 현상을 모니터링하고 외부 환경을 계측하는 계측모듈을 개발하고, 계측된 정보 데이터를 전송할 수 있는 통신모듈을 통하여 원격지에서 태양광 발전 시스템의 동작 상태를 모니터링 하도록 설계하였다. 또한 스마트폰을 기반으로 구축된 태양광 발전 시스템을 실시간으로 관리하고 모니터링 할 수 있는 모바일 관리 시스템을 제시하고자 한다.

태양광 발전소의 전기설비 설계 및 저압 계통연계 적용사례에 관한 연구 (A Study on electric facilities plan and application of low-voltage grid connection for a photovoltaic electric power station)

  • 임경미;김경화
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.305-308
    • /
    • 2009
  • This paper resents a study on the electric facilities plan and application of low-voltage grid connection for a photovoltaic electric power station. The analysis for an installation cost is carried out and a new plan to solve the problem caused by a voltage drop in a low-voltage grid connection is devised. It is expected that the results can be usefully applied to spread the photovoltaic electric power station.

  • PDF

Effects of Wind Generation Uncertainty and Volatility on Power System Small Signal Stability

  • Shi, Li-Bao;Kang, Li;Yao, Liang-Zhong;Qin, Shi-Yao;Wang, Rui-Ming;Zhang, Jin-Ping
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.60-70
    • /
    • 2014
  • This paper discusses the impacts of large scale grid-connected wind farm equipped with permanent magnet synchronous generator (PMSG) on power system small signal stability (SSS) incorporating wind generation uncertainty and volatility. Firstly, a practical simplified PMSG model with rotor-flux-oriented control strategy applied is derived. In modeling PMSG generator side converter, the generator-voltage-oriented control strategy is utilized to implement the decoupled control of active and reactive power output. In modeling PMSG grid side converter, the grid-voltage-oriented control strategy is applied to realize the control of DC link voltage and the reactive power regulation. Based on the Weibull distribution of wind speed, the Monte Carlo simulation technique based is carried out on the IEEE 16-generator-68-bus test system as benchmark to study the impacts of wind generation uncertainty and volatility on small signal stability. Finally, some preliminary conclusions and comments are given.

Enhancing Effects of NaHSO3 on Corrosion of T91 Steel

  • Wu, Tangqing;Tan, Yao;Wang, Jun;Xu, Song;Liu, Lanlan;Feng, Chao;Yin, Fucheng
    • Journal of Electrochemical Science and Technology
    • /
    • 제11권4호
    • /
    • pp.368-378
    • /
    • 2020
  • In the paper, corrosion behavior of T91 steel in different concentrations of NaHSO3 solution was studied in combination with scanning electron microscope (SEM) and electrochemical measurements. The results showed that the steel exhibited active anodic dissolution characteristics in the solution, and NaHSO3 concentration affected both cathodic and anodic behaviors. The steel surface was covered by intact corrosion products in the solutions, but the compactness and mechanical properties of the corrosion products degraded with the increase of NaHSO3 concentration. In low-concentration NaHSO3 solution the steel tended to undergo uniform corrosion with slight corrosion pits, but its corrosion mode gradually transited to localized corrosion as the NaHSO3 concentration increased. The mechanical property degradation of the corrosion products caused by sulfur compounds and the pH decrease of the solution are the important factors to accelerating its corrosion process.

Single Line-to-ground Fault Location and Information Modeling Based on the Interaction between Intelligent Distribution Equipment

  • Wang, Lei;Luo, Wei;Weng, Liangjie;Hu, Yongbo;Li, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1807-1813
    • /
    • 2018
  • In this paper, the fault line selection and location problems of single line-to-ground (SLG) fault in distribution network are addressed. Firstly, the adaptive filtering property for empirical mode decomposition is formulated. Then in view of the different characteristics showed by the intrinsic mode functions(IMF) under different fault inception angles obtained by empirical mode decomposition, the sign of peak value about the low-frequency IMF and the capacitance transient energy is chosen as the fault line selection criteria according to the different proportion occupied by the low-frequency components. Finally, the fault location is determined based upon the comparison result with adjacent fault passage indicators' (FPI) waveform on the strength of the interaction between the distribution terminal unit(DTU) and the FPI. Moreover, the logic nodes regarding to fault line selection and location are newly expanded according to IEC61850, which also provides reference to acquaint the DTU or FPI's function and monitoring. The simulation results validate the effectiveness of the proposed fault line selection and location methods.

기계학습 기반 전력망 상태예측 모델 성능 유지관리 자동화 기법 (Management Automation Technique for Maintaining Performance of Machine Learning-Based Power Grid Condition Prediction Model)

  • 이해성;이병성;문상근;김준혁;이혜선
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.413-418
    • /
    • 2020
  • 초기 학습 데이터의 과적합으로 인한 전력망 상태예측 모델의 성능 감소를 방지하고 예측모델의 예측 정확도 유지를 통한 계속적인 현장활용을 위해서는 기계학습 모델의 예측 정확도를 지속적으로 관리할 필요가 있다. 이를 위해, 본 논문에서는 다양한 요인에 의해 끊임없이 변화하는 전력망 상태 데이터의 특성을 고려하여 예측모델의 정확성과 신뢰성을 높이고 현장 적용 가능한 수준의 품질을 유지하기 위한 기계학습 기반 전력망 상태예측 모델의 성능 유지관리 자동화 기법을 제안한다. 제안 기법은 워크플로우 관리 기술의 적용을 통해 전력망 상태예측 모델 성능 유지관리를 위한 일련의 태스크들을 워크플로우의 형태로 모델링하고 이를 자동화하여 업무를 효율화 하였다. 또한, 기존 기술에서는 시도되지 않았던 학습데이터의 통계적 특성 변화 정도와 예측의 일반화 수준을 모두 고려한 예측모델의 성능 평가를 통해 성능 결과의 신뢰성을 확보하고 이를 통해 예측 모델의 정확도를 일정 수준으로 유지관리하고 더욱 성능이 우수한 예측모델의 신규 개발이 가능하다. 결과적으로 본 논문에서 제안하는 전력망 상태예측 모델 성능 유지관리 자동화 기법을 통해 예측모델의 성능 저하문제를 해결하여 분산자원 연계 등 외부 환경의 변화에 유연한 예측모델 관리를 통해 정확성과 신뢰성이 보장된 예측 모델의 지속적인 활용이 가능하다.

Static Equivalent Model of Inverter-based Distributed Energy Resource for Fault Analysis of Power Distribution Grid

  • Kim, Dong-Eok;Cho, Namhun;Yang, Seung-Kwon
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권4호
    • /
    • pp.569-575
    • /
    • 2016
  • In this paper, we propose a method to develop a static equivalent model of an inverter-based distributed energy resource (DER), where the model is used for a steady-state fault analysis of a power grid. First, we introduce the characteristics of an inverter-based DER as well as its general configuration. Then, we derive the equivalent model of the DER on the basis of the characteristics. Last, the performance of the proposed method is proven by the results of computer simulations.

Lessons Learned from Energy Storage System Demonstrations for Primary Frequency Control

  • Yu, Kwang-myung;Choi, In-kyu;Woo, Joo-hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제4권2호
    • /
    • pp.107-114
    • /
    • 2018
  • In recent years, ESS (Energy Storage System) has been widely used in various parts of a power system. Especially, due to its fast response time and high ramp rate, ESS is known to play an important role in regulating grid frequency and providing rotational inertia. As the number of installed and commercially operating ESSs increases, the reliability becomes an important issue. This paper introduces control schemes and presents its test method for grid-connected ESS for primary frequency regulation. The test method allows to verify the control operation in the individual operation mode and state. A validation of the method through actual ESS test in a electrical substation is presented in the case study section.