• 제목/요약/키워드: Electric power equipments

검색결과 218건 처리시간 0.03초

에너지 절감 기법을 적용한 냉동 냉장 창고 운영에 관한 연구 (A Study on Refrigeration warehouse operation for Energy saving technique)

  • 김대균;권중동;함년근;이상집;김익환;이승환;이훈구;한경희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.182-184
    • /
    • 2005
  • The human beings have Increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, intelligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

공장전기설비에서의 누전차단기 오동작과 전력품질 분석 (Power Quality Analysis and Failure of Earth Leakage Breakers in Plant)

  • 이상의;유재근;전정채;전현재;허혜성;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.479-481
    • /
    • 2007
  • This paper presented a actual conditions on a false-tripping of ELB(Earth Leakage Breakers) and an assessment of the harmonics due to non-linear electronic equipment such as personal computers, rectifier, electric furnace and test equipments in plant installations. Actual conditions on a failure of ELB were surveyed and analyzed by making up a question to safety managers of plant installations. Also, power quality measurements such as harmonic currents, voltage and current waveform and current imbalance were made at various plant installations where nuisance tripping of ELB is often occurred. The results of this study can be used in making decisions regarding cause of ELB trip and operating and tripping characteristics test of ELB when subjected to distorted current waveform.

  • PDF

전력 사용설비의 에너지 절감방안 및 관리를 위한 진단기법 (Techniques of Management and Energy saving by using Power installation)

  • 이상집;전기영;함년근;김대균;강승욱;오봉환;이훈구;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1102-1104
    • /
    • 2003
  • The human beings have increased concern about energy saving and alternative energy. The Power demand has increased the growth of industry and the improvement of lift. We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed energy saving by using an electric ballast. The load installation should be promoted to rational power management according to the network, intelligent and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

저가(低價), 고(高) 밀도(密度)의 자려식 DC/DC 컨버터에 관한 연구 (A Study on a Self Oscillating DC/DC Converter with Low Cost, High Power Density)

  • 백주원;유동욱;오성철;위계조;김명한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.860-862
    • /
    • 1993
  • This paper presents a study on a self oscillating dc/dc converter with low cost, high power density. This converter only consists of power filter, switch and comparater and time delay reduction parts. But it has better characteristics than the conventional self-oscillating dc/dc converter. And it can be made by a few devices and can be smaller size. These type of converters find their applications in many industrial equipments. And the performances of the proposed system are verified through expriment.

  • PDF

광원별 센서등기구의 대기전력 특성에 관한 연구 (A Study on the Standby Power Characteristics of Sensor Luminaires)

  • 박창용;서정현
    • 조명전기설비학회논문지
    • /
    • 제28권10호
    • /
    • pp.9-15
    • /
    • 2014
  • Standby power, so called an electric vampire, is a power which is consumed by appliances and office equipments connected to power sources while the devices are not performing. Sensor luminaires consist of PIR(Pyroelectric Infrared Ray) sensor, illuminance sensor(CdS), and light source. The sensor luminaires are one of the devices that consume a huge amount of standby power; it stands by for an average sum of 23 hours a day and performs only when moving subjects are detected under it, which barely takes up an hour per day. The purpose of this study is to provide basic materials to the selection of standby power items and to enable to explore a way to decrease the standby power by measuring and analyzing the power consumption of sensor luminaires. According to the results, the average standby power of LED sensor luminaires is 1.1W which is significantly higher than other products, and decrease in the standby power consumption of SMPS is important through the measurement.

신경망을 이용한 원자력발전소의 주요 고장진단 (The Fault Diagnosis using Neural Networks for Nuclear Power Plants)

  • 권순일;이종규;송치권;배현;김성신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2723-2725
    • /
    • 2001
  • Nuclear power generations have been developed gradually since 1950. Nowadays, 440 nuclear power generations are taking charge of 16% of electric power production in the world. The most important factor to operate the nuclear power generations is safety. It is not easy way to control nuclear power generations with safety because nuclear power generations are very complicated systems. In the main control room of the nuclear power generations, about 4000 numbers of alarms and monitoring devices are equipped to handle the signals corresponding to operating equipments. Thus, operators have to deal with massive information and to grasp the situation immediately. If they could not achieve these task, then they should make big problem in the power generations Owing to too many variables, operators could be also in the uncontrolled situation. So in this paper, automatic systems to diagnose the fault are constructed using 2 steps neural networks. This diagnosis method is based on the pattern of the principal variables which could represent the type and severity of faults.

  • PDF

육상용 LED 램프의 선박 적응력에 관한 연구 (A study on the accommodation of common LED to shipboard)

  • 정지현;박환철;김용주;한승재;서상도;김민석
    • 수산해양기술연구
    • /
    • 제46권4호
    • /
    • pp.503-508
    • /
    • 2010
  • Common LED (Light Emitting Diode) lamp has many advantages to compare with fluorescent lamp, long life and no pollution matter like the mercury. The LED lamp is a good light source especially for shipboard lighting because of its compact structure which prevents explosion and shock. Also, low maintenance cost is expected due to its longer life time in comparison with conventional lamps. The LED lamp, however, need some estimates that change of voltage and frequency, vibration, moisture on board to definite accommodation of the LED lamp to shipboard. The purpose of this study is to compare physical properties of a fluorescent lamp with one of the common LED lamp so as to analyze accommodation of common LED lamp on board. This study was carried out in two stages. First, temperature, humidity of illumination, voltage, electric current, frequency and electric power were measured by using experimental equipments. Second, a comparative analysis of consumption electric power, annual oil charge, annual CO2 emission and lamp life time, etc of the fluorescent lamp and common LED one was made. As a result of the study, the consumption electric power of fluorescent lamp was 50% higher than one of the common LED lamp. As a result of measuring life time, it was found that life time of common LED lamp was more about 3.5 fold than one of the fluorescent lamp. Considering these results, it's thought that common LED lamp is verified that energy saving is possible and using is possible as substitute for fluorescent lamp on board.

전력설비용 가교 Polyethlene의 Glass 전이점에서의 전기전도 특성에 관한 연구 (A Study on Electric Conduction Characteristic in the Glass Transition Point of electric Power Equipments Cross - Linked Polyethylene)

  • 김강원;서장수;김병인;국상훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1991년도 추계학술발표회논문집
    • /
    • pp.64-68
    • /
    • 1991
  • It happened that there was a sudden peak with the capacity of change, when I measured the capacity of change, cubical expansion and Thermally Stimulated Current on the Cross - Linked Polythylene. Crystal melting began at 375 K and changed into formaless shapeless at 380 K. The conduct of a particle on the surfase of dipole, electron trap was founded to be ion conduction nature under the low electronic field, wherase, the electron nature under the high electronic field. Consequentity, under the semi-conduction layer electronic a particle was injected to inter-fase and accumulated for a time and appeared to be TSC.

  • PDF

액체 질소중 교류방전 진전에 따른 방사전자파의 주파수 스펙트럼 특성 (The Characteristics of Frequency Spectrum of Radiated Electromagnetic Waves with AC Discharge Progress in Liquid Nitrogen)

  • 박광서;윤대희;이상훈;이현동;김충년;최병주;김기채;이광식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권3호
    • /
    • pp.123-129
    • /
    • 2003
  • In this paper, a relationship between AC discharge progress and the radiated electromagnetic waves was investigated by measuring electromagnetic waves using a biconical antenna and a spectrum analyzer. The frequency spectrum of the radiated electromagnetic waves were measured at the atmospheric pressure in liquid nitrogen($LN_2$) during partial discharges progressed by AC high voltage in nonuniform electric field. Front the results of this study, a new method was introduced for measurement and analysis of the radiated electromagnetic waves with discharge progress in $LN_2$ Besides. according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting partial discharge and estimating discharge progress could be possible. It is considered that these results obtained from this investigation may be used as fundamental data for diagnosis and prediction of electric insulations about superconducting and cryogenic power equipments.

철도차량기지내에서의 경제성을 고려한 접지설계에 관한 연구 (A study of grounding system design with economical efficiency in electric rolling stocks facilities)

  • 장진영;김재문;김양수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.6-9
    • /
    • 2009
  • Recently, there have been studied the importance of the grounding system, as electrical equipments installed in the building, such as intelligent building. The object of grounding of electrical facilities is to protect human and machine damage from the power supply interruption high voltage by use of the accident current dissipating into the ground. In this paper, we is proposed to design of grounding system with economical efficiency in electric rolling stocks facilities. To make efficient ground, ground potential rise must be controlled in the way of overall lowering and evenness instead of independent grounding method with respect to electrical facilities.

  • PDF