• Title/Summary/Keyword: Electric muscle stimulator

Search Result 8, Processing Time 0.019 seconds

A Prototype Development of Personal Low-frequency Stimulator with Characteristic Analysis (개인용 저주파 자극기의 특성분석 및 Prototype개발)

  • Lee, Gi-Song;Lee, Dong-Ha;Yu, Jae-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.349-352
    • /
    • 2003
  • A personal low-frequency stimulator is a portable device to relax muscle pains of a person. The stimulator generates combined low-frequency pulses to be applied to pads attached to painful muscles. This paper reports a development of such device with its characteristic analyses. The major components of our stimulator are MCU, high-voltage generating circuit part, high-voltage switching circuit part, input switch part and display unit. High-voltage generating circuit is designed by using a boost converter circuit and allows user control of the output voltage. High-voltage switching circuit, controlled by MCU, generates output voltage to be applied to pads. Input switch part is composed of power supply, intensity selection, mode selection and memory. Display unit adopts a text LCD module to display modes, Intensity, output frequency and user set-up time. Our designed safety circuit, to protect human body from possible electric shock, slowly increases the output voltage to the selected output intensity. It continuously checks the output pulse shape and disable the output when dangerous pulses are detected. This paper also shows some experimental results.

  • PDF

The Effects of Diet-Gel and Electric Muscle Stimulator on Waist Circumference Reduction (다이어트젤과 전기근육자극기가 허리둘레 감소에 미치는 영향)

  • Lee, Gwang-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.2
    • /
    • pp.453-464
    • /
    • 2021
  • Abdominal obesity is increasing due to a decrease in physical activity and westernization of diet in busy daily life. Therefore, in order to satisfy the desire for body shape management, a management program with high efficiency versus time is needed. In this study, the diet-gel (i.e., slimming cosmetics) with the electrical muscle stimulation therapy was used to promote the effect of reducing waist circumference and body fat mass (or abdominal fat). For men and women in their twenties, the subjects simply applied diet-gel to their waist, wore EMS, and massaged for 20 minutes twice a day after waking up and before going to sleep. The experiment period was carried out for 2 weeks. The reduction of subcutaneous fat was observed using non-contrast CT, and it was confirmed by measuring waist circumference and body fat mass. In conclusion, the developed EMS and diet-gel combination program showed excellent waist management effects by reducing waist circumference by about 3 cm (p<0.001) and body fat mass by about 1 kg (p<0.01). This result suggests that the use of EMS shows a massage effect by muscle stimulation, and plays a role in promoting fat decomposition by helping the absorption of diet gel.

Wound Infection of Spinal Cord Stimulator: A Case Report (척수 신경 자극기 삽입부 감염의 치험례)

  • Kim, Jong-Sok;Oh, Deuk-Young;Seo, Je-Won;Lee, Jung-Ho;Rhie, Jong-Won;Ahn, Sang-Tae
    • Archives of Plastic Surgery
    • /
    • v.37 no.1
    • /
    • pp.71-74
    • /
    • 2010
  • Purpose: Nowadays spinal cord stimulator is frequently used for the patients diagnosed as complex regional pain syndrome. The lead is placed above the spinal cord and connected to the stimulation generator, which is mostly placed in the subcutaneous layer of the abdomen. When the complication occurs in the generator inserted site, such as infection or generator exposure, replacement of the new generator to another site or pocket of the abdomen would be the classical choice. The objective of our study is to present our experience of the effective replacement of the existing stimulation generator from subcutaneous layer to another layer in same site after the wound infection at inexpensive cost and avoidance of new scar formation. Methods: A 50-year-old man who was diagnosed as complex regional pain syndrome after traffic accident received spinal cord stimulator, Synergy$^{(R)}$ (Medtronic, Minneapolis, USA) insertion 1 month ago by anesthetist. The patient was referred to our department for wound infection management. The patient was presented with erythema, swelling, thick discharge and wound disruption in the left upper quadrant of the abdomen. After surgical debridement of the capsule, the existing generator replacement beneath the anterior layer of rectus sheath was performed after sterilization by alcohol. Results: Patient's postoperative course was uneventful without any complication and had no evidence of infection for 3 months follow-up period. Conclusion: Replacement of existing spinal cord stimulation generator after sterilization between the anterior layer of rectus sheath and rectus abdominis muscle in the abdomen will be an alternative treatment in wound infection of stimulator generator.

EFFECT OF D-PROPRANOLOL ON TRANSMEMBRANE ACTION POTENTIAL OF CARDIAC PAPILLARY MUSCLE OF CAT (고양이 유두근의 활동전압에 미치는 d-propranolol의 영향)

  • Lee, Jong-Heun;Kim, Joong-Soo
    • The Journal of the Korean dental association
    • /
    • v.16 no.7 s.110
    • /
    • pp.531-536
    • /
    • 1978
  • Adult cats were light anesthetized with ethyl ether and heart was removed fastly. cardiac papillary muscle was dissected from heart in organ bath con taining Tyrode solution saturated with 95% O₂+5% CO₂, and prepared papillary muscles were placed in Tyrode solution that was continuously circulated and gassed with 95% O₂+5% CO₂at 32℃. The isolated papillary muscle was stimulated continuously with platinum pin electrode at frequency of 15/min and 90/min by means of electric stimulator and transmembrane action potentials were recorded with microelectrdes on the oscilloscope. The drug used was d-propranolol and its concentration was 0.5, 1.5 and 5.0 mg/L. The results obtained were as follows: 1. D-propranolol increased the threshold voltage of papillary muscle and raised by average of 213.6% of control. 2. D-propranolol had no effect on duration of action potential. 3. Conduction time of isolated papillary muscle was increased by d-propranolol and its effect was prominent at frequency of 90/min. 4. the maximum upstroke velocity was decreased by d-propranolol and its effect was dose-depndent decrease.

  • PDF

Effect of Vagus Nerve Electrical Stimulation on Respiratory Muscle Activity and Lung Capacity during Deep Breathing (Case Study) (깊은호흡 시 미주신경 전기자극이 호흡근 활성과 호흡능력에 미치는 효과(사례 연구))

  • Moon, Hyunju
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.2
    • /
    • pp.181-187
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the activity of respiratory muscle and lung capacity during deep breathing with electrical stimulation of the vagus nerve. Methods: This study was conducted on 30 healthy adults in their 20s. Subjects were randomly performed to deep breathing or deep breathing with vagus nerve electrical stimulation. All subjects' diaphragm and internal oblique muscle activity were measured during deep breathing by electromyography, and lung capacity was measured by spirometry immediately after beep breathing. In the vagus nerve stimulation method, the surface electrode was cut into the left ear and then electrically stimulated using a needle electric stimulator. Results: The activity of diaphragm was significantly increased in deep breathing with vagus nerve electrical stimulation than in deep breathing. However, lung capacity did not show any significant difference according to the condition. Conclusion: Vagus nerve electrical stimulation could induce diaphragm activity more than deep breathing alone. Deep breathing with vagus nerve electrical stimulation may enhance the activity of the respiratory muscles and is expected to be an effective treatment for the elderly or COPD patients with poor breathing ability.

-On Acupoints & Trigger Points- Muscle fatigue evaluation using the Micro-electromagnetic stimulation (-경혈 및 트리거 포인트에서- 미약 자기장을 이용한 근피로 회복 평가)

  • Kim, Soo-Byung;Lee, Na-Ra;Shim, Tae-Kyu;Lee, Seung-Wook;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.5
    • /
    • pp.1231-1239
    • /
    • 2010
  • The aim of this study was developing the non-invasive focused magnetic stimulation system(NI_FMSS) that can stimulates acupoints which are small parts and knotted muscular tissues. To evaluate pain treatment effect of the NI_FMSS, we caused muscle fatigue to 25 subjects in biceps of the arm. Then, we stimulated acupoints(trigger points) HT2 using low frequency stimulator(10 subjects) and NI_FMSS(10 subjects). The other 5 subjects had not been stimulated. We analyzed muscle fatigue recovery with median frequency, RMS and median power in frequency domain for 5 days. We checked the magnetic stimulation effect on acupoint by evaluation of muscle fatigue recovery. Therefore, we identified that the NI_FMSS was more efficient system to relieve muscle pain than electric-stimulation system.

THE INHIBITORY EFFECT OF LOW FREQUENCY ELECTRICAL STIMULATION ON THE DENTAL AND GINGIVAL PAIN OF DOG (저빈도 전기자극이 개의 치아 및 치은에 대한 동통억제효과)

  • Kweon, Hoon;Song, Hyung-Geun;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.525-536
    • /
    • 1996
  • The purpose of this study was to investigate the effect of electrical anesthesia induced by non-acupuncture point stimulation on inhibition of amplitude of digastric EMG evoked by noxious electrical stimuli in teeth and gingiva. Experiments were performed with dogs anesthetized with intraperitoneal pentobarbital sodium in an initial dose of 30mg/kg. Maintenance doses of 4.0ml/hour were given through a cannula in the femoral vein using a constant infusion pump. Anterior belly of digastric muscle was exposed and a pair of 0.1mm wire electrodes were inserted for E.M.G. recording. Bipolar electrodes were inserted into the labial and lingual surface of upper canine and the labial area of upper gingiva. Noxious stimuli were delivered to the tooth and gingiva through those electrodes by electric stimulator. Non-acupuncture point stimulation of 2Hz was delivered bilaterally to the femoral area. Amplitudes of digastric E.M.G. were measured from the oscilloscope and the monitor connected to amplifier at different intensities of electronic anesthesia of 1 volt, 4 volt and 10 volt. The inhibited rate of the amplitudes of digastric E.M.G. were analysed statistically with paired t-test. The following results were obtained : 1. Non-acupuncture point stimulation with intensities of 1 volt, 4 volt and 10 volt showed the inhibitory effect on pain of 15%, 25% and 16% in teeth and 15%, 18% and 12% in gingiva respectively 2. In tooth, statistical significance was observed between control and each group. In gingiva, there was statistical significance between control and group 1, 2 except group 3 From these results, low frequency electrical stimulation of non-acupuncture point resulted in reducing of dental and gingival pain, it could be used as adjunct to other pain control methods.

  • PDF