• 제목/요약/키워드: Electric muscle stimulator

검색결과 8건 처리시간 0.027초

개인용 저주파 자극기의 특성분석 및 Prototype개발 (A Prototype Development of Personal Low-frequency Stimulator with Characteristic Analysis)

  • 이기송;이동하;유재택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.349-352
    • /
    • 2003
  • A personal low-frequency stimulator is a portable device to relax muscle pains of a person. The stimulator generates combined low-frequency pulses to be applied to pads attached to painful muscles. This paper reports a development of such device with its characteristic analyses. The major components of our stimulator are MCU, high-voltage generating circuit part, high-voltage switching circuit part, input switch part and display unit. High-voltage generating circuit is designed by using a boost converter circuit and allows user control of the output voltage. High-voltage switching circuit, controlled by MCU, generates output voltage to be applied to pads. Input switch part is composed of power supply, intensity selection, mode selection and memory. Display unit adopts a text LCD module to display modes, Intensity, output frequency and user set-up time. Our designed safety circuit, to protect human body from possible electric shock, slowly increases the output voltage to the selected output intensity. It continuously checks the output pulse shape and disable the output when dangerous pulses are detected. This paper also shows some experimental results.

  • PDF

다이어트젤과 전기근육자극기가 허리둘레 감소에 미치는 영향 (The Effects of Diet-Gel and Electric Muscle Stimulator on Waist Circumference Reduction)

  • 이광희
    • 한국응용과학기술학회지
    • /
    • 제38권2호
    • /
    • pp.453-464
    • /
    • 2021
  • 바쁜 일상 속에서 신체 활동량의 감소와 식생활의 서구화 등으로 인한 복부 비만의 발생률이 높아지고 있다. 따라서 체형 관리에 대한 욕구를 충족시키기 위해 시간 대비 고 효율의 관리 프로그램이 필요하다. 본 연구에서는 전기근육자극요법 (electric muscle stimulation therapy)을 활용하여 다이어트젤(슬리밍 화장품)과의 복합사용에 의하여 허리둘레 및 체지방량 (또는 복부의 지방)를 감소 효과를 촉진시켰다. 연구 대상자는 20대 성인 남녀로 다이어트젤을 허리 부위에 단순 도포를 한 후, 그 위에 EMS를 착용하여 기상 후와 취침 전에 1일 2회 20분간 마사지를 실시하였다. 실험 기간은 2주 동안 실시되었다. 지방분해 촉진 효과는 비 조영 CT를 활용하여 피하지방의 감소에 대한 관찰이 되었으며, 이와 함께 허리둘레와 체지방량 측정으로 확인되었다. 결론적으로 개발된 EMS와 다이어트젤의 동시 사용 프로그램은 약 3 cm (p<.001)의 허리둘레 감소와 약 1 kg (p<.01)의 체지방량 감소를 나타내어 허리라인 관리에 탁월한 효과가 있음을 입증하였다. 이는 EMS의 활용이 근육 자극에 의한 마사지 효과를 나타내며 다이어트젤의 흡수를 도와 지방 분해를 촉진시키는 역할을 하는 것으로 사료된다.

척수 신경 자극기 삽입부 감염의 치험례 (Wound Infection of Spinal Cord Stimulator: A Case Report)

  • 김종석;오득영;서제원;이중호;이종원;안상태
    • Archives of Plastic Surgery
    • /
    • 제37권1호
    • /
    • pp.71-74
    • /
    • 2010
  • Purpose: Nowadays spinal cord stimulator is frequently used for the patients diagnosed as complex regional pain syndrome. The lead is placed above the spinal cord and connected to the stimulation generator, which is mostly placed in the subcutaneous layer of the abdomen. When the complication occurs in the generator inserted site, such as infection or generator exposure, replacement of the new generator to another site or pocket of the abdomen would be the classical choice. The objective of our study is to present our experience of the effective replacement of the existing stimulation generator from subcutaneous layer to another layer in same site after the wound infection at inexpensive cost and avoidance of new scar formation. Methods: A 50-year-old man who was diagnosed as complex regional pain syndrome after traffic accident received spinal cord stimulator, Synergy$^{(R)}$ (Medtronic, Minneapolis, USA) insertion 1 month ago by anesthetist. The patient was referred to our department for wound infection management. The patient was presented with erythema, swelling, thick discharge and wound disruption in the left upper quadrant of the abdomen. After surgical debridement of the capsule, the existing generator replacement beneath the anterior layer of rectus sheath was performed after sterilization by alcohol. Results: Patient's postoperative course was uneventful without any complication and had no evidence of infection for 3 months follow-up period. Conclusion: Replacement of existing spinal cord stimulation generator after sterilization between the anterior layer of rectus sheath and rectus abdominis muscle in the abdomen will be an alternative treatment in wound infection of stimulator generator.

고양이 유두근의 활동전압에 미치는 d-propranolol의 영향 (EFFECT OF D-PROPRANOLOL ON TRANSMEMBRANE ACTION POTENTIAL OF CARDIAC PAPILLARY MUSCLE OF CAT)

  • 이종흔;김중수
    • 대한치과의사협회지
    • /
    • 제16권7호통권110호
    • /
    • pp.531-536
    • /
    • 1978
  • Adult cats were light anesthetized with ethyl ether and heart was removed fastly. cardiac papillary muscle was dissected from heart in organ bath con taining Tyrode solution saturated with 95% O₂+5% CO₂, and prepared papillary muscles were placed in Tyrode solution that was continuously circulated and gassed with 95% O₂+5% CO₂at 32℃. The isolated papillary muscle was stimulated continuously with platinum pin electrode at frequency of 15/min and 90/min by means of electric stimulator and transmembrane action potentials were recorded with microelectrdes on the oscilloscope. The drug used was d-propranolol and its concentration was 0.5, 1.5 and 5.0 mg/L. The results obtained were as follows: 1. D-propranolol increased the threshold voltage of papillary muscle and raised by average of 213.6% of control. 2. D-propranolol had no effect on duration of action potential. 3. Conduction time of isolated papillary muscle was increased by d-propranolol and its effect was prominent at frequency of 90/min. 4. the maximum upstroke velocity was decreased by d-propranolol and its effect was dose-depndent decrease.

  • PDF

깊은호흡 시 미주신경 전기자극이 호흡근 활성과 호흡능력에 미치는 효과(사례 연구) (Effect of Vagus Nerve Electrical Stimulation on Respiratory Muscle Activity and Lung Capacity during Deep Breathing (Case Study))

  • 문현주
    • 대한통합의학회지
    • /
    • 제7권2호
    • /
    • pp.181-187
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the activity of respiratory muscle and lung capacity during deep breathing with electrical stimulation of the vagus nerve. Methods: This study was conducted on 30 healthy adults in their 20s. Subjects were randomly performed to deep breathing or deep breathing with vagus nerve electrical stimulation. All subjects' diaphragm and internal oblique muscle activity were measured during deep breathing by electromyography, and lung capacity was measured by spirometry immediately after beep breathing. In the vagus nerve stimulation method, the surface electrode was cut into the left ear and then electrically stimulated using a needle electric stimulator. Results: The activity of diaphragm was significantly increased in deep breathing with vagus nerve electrical stimulation than in deep breathing. However, lung capacity did not show any significant difference according to the condition. Conclusion: Vagus nerve electrical stimulation could induce diaphragm activity more than deep breathing alone. Deep breathing with vagus nerve electrical stimulation may enhance the activity of the respiratory muscles and is expected to be an effective treatment for the elderly or COPD patients with poor breathing ability.

-경혈 및 트리거 포인트에서- 미약 자기장을 이용한 근피로 회복 평가 (-On Acupoints & Trigger Points- Muscle fatigue evaluation using the Micro-electromagnetic stimulation)

  • 김수병;이나라;심태규;이승욱;이용흠
    • 한국정보통신학회논문지
    • /
    • 제14권5호
    • /
    • pp.1231-1239
    • /
    • 2010
  • 이에 본 연구에서는 비침습적인 방식으로 국소적 부위인 경혈과 Trigger Point에서 경결된 근조직과 신경조직을 자극할 수 있는 자기장 자극 시스템을 제작하였다. 시스템을 이용하여 가정용 저주파치료기기와 동일한 조건에서 상완 이두박근의 근피로 유발 후 근피로 회복을 평가하였다. 경혈과 Trigger Point의 해부학적 위치가 동일한 청영혈(HT2)를 자극위치로 선정하였다. 등척성 운동을 통하여 25명의 일반인에게 근피로를 유발시켰으며, 무자극 5명, 저주파 치료기기의 전기자극 10명, 자기장 자극 10명으로 분류하였다. 자극시간은 5분으로 하여 자극하였으며, 5일동안 EMG를 측정하여 관찰하였다. EMG를 주파수영역에서 분석해본 결과, 무자극의 근피로 회복률이 가장 저조했으며, 저주파치료기기의 전기자극보다 자기장 자극이 근피로 회복에 효과적인 것으로 확인되었다.

저빈도 전기자극이 개의 치아 및 치은에 대한 동통억제효과 (THE INHIBITORY EFFECT OF LOW FREQUENCY ELECTRICAL STIMULATION ON THE DENTAL AND GINGIVAL PAIN OF DOG)

  • 권훈;송형근;이상호
    • 대한소아치과학회지
    • /
    • 제23권2호
    • /
    • pp.525-536
    • /
    • 1996
  • The purpose of this study was to investigate the effect of electrical anesthesia induced by non-acupuncture point stimulation on inhibition of amplitude of digastric EMG evoked by noxious electrical stimuli in teeth and gingiva. Experiments were performed with dogs anesthetized with intraperitoneal pentobarbital sodium in an initial dose of 30mg/kg. Maintenance doses of 4.0ml/hour were given through a cannula in the femoral vein using a constant infusion pump. Anterior belly of digastric muscle was exposed and a pair of 0.1mm wire electrodes were inserted for E.M.G. recording. Bipolar electrodes were inserted into the labial and lingual surface of upper canine and the labial area of upper gingiva. Noxious stimuli were delivered to the tooth and gingiva through those electrodes by electric stimulator. Non-acupuncture point stimulation of 2Hz was delivered bilaterally to the femoral area. Amplitudes of digastric E.M.G. were measured from the oscilloscope and the monitor connected to amplifier at different intensities of electronic anesthesia of 1 volt, 4 volt and 10 volt. The inhibited rate of the amplitudes of digastric E.M.G. were analysed statistically with paired t-test. The following results were obtained : 1. Non-acupuncture point stimulation with intensities of 1 volt, 4 volt and 10 volt showed the inhibitory effect on pain of 15%, 25% and 16% in teeth and 15%, 18% and 12% in gingiva respectively 2. In tooth, statistical significance was observed between control and each group. In gingiva, there was statistical significance between control and group 1, 2 except group 3 From these results, low frequency electrical stimulation of non-acupuncture point resulted in reducing of dental and gingival pain, it could be used as adjunct to other pain control methods.

  • PDF