표본건물 계측에 의한 업무시설에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석 (Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use Based on Measurements of Sample Office Building)

  • 임한영;임수현;진혜선;김성임;이수진;임재한;송승영
    • 대한건축학회논문집:구조계
    • /
    • 제34권8호
    • /
    • pp.19-27
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and $CO_2$ emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 19 sample office buildings in Seoul. In addition, the estimated site EUIs by end use were compared to the U.S. Commercial Buildings Energy Consumption Survey (CBECS) 2012 data. Average site EUIs by end use were found to be in the order of electric appliance (typical floors) > heating > cooling > lighting > air movement > domestic hot water > vertical transportation > city water supply. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the CBECS 2012 data, it was found that the site EUIs were similar for heating, cooling, domestic hot water, and electric appliance, etc., but slightly different for lighting and air movement. The number of sample office buildings will continue to increase until 2020 (total number of samples 85) and intensities data by end use will be continuously updated through continuous collection of measurement data.

웨어러블 테크놀로지에 기반을 둔 고기능 스마트 재킷 설계 제안 (Suggestion of Functional Smart Jacket Based on Wearable Technology)

  • 이정란
    • 한국의류학회지
    • /
    • 제35권3호
    • /
    • pp.292-303
    • /
    • 2011
  • This research suggested a draft proposal for a smart jacket design, which has applied wearable technologies to provide convenience in daily life. The smart jacket combined with a vest was the casual item for autumn and winter. The heating device was composed of the heating element, battery, controller, electric wire, connector, switch, and charger. A stable electronic conductor fiber of good heating effect with a flexible zigzag form has been selected for the heating element. The lighting device has been made in a way that attaches the LED and its power controller in the same mechanical device. As the result of the wearing test, the heating effect turned out to be effective in the order of: back, both the back and abdomen and only the abdomen. When wearing a smart jacket, the back and abdomen have been selected as favorable body parts for heating. Pockets and hems are selected as the adequate place to attach the LED lighting, and the brightness of LED lighting has turned out to be suitable and useful. Based on the test results, the first draft proposal has attached the heating element only in the back and its controller located in the inside pocket of the vest. In addition, the LED has been attached to the front pocket of the jacket. As to the second draft proposal, heating elements have been placed in the back and the abdomen. Each controller for the heating elements has been placed in the front and inside pocket of vest, and the LED lighting has been attached to the hem of the jacket. The smart jacket combined with a wearable device was assessed by functioning categories. The user showed a high satisfaction in the heating and illuminating function of a smart jacket.

Supplementary Blue and Red Radiation at Sunrise and Sunset Influences Growth of Ageratum, African Marigold, and Salvia Plants

  • Heo, Jeong-Wook;Lee, Yong-Beom;Bang, Hea-Son;Hong, Seung-Gil;Kang, Kee-Kyung
    • 한국환경농학회지
    • /
    • 제30권4호
    • /
    • pp.382-389
    • /
    • 2011
  • BACKGROUND: Light-emitting diodes (LEDs) with lower electric cost and the specific wavelength have been considering as a novel light source for plant production in greenhouse conditions as well as in a closed culture system. Supplementary lighting for day-length extension was considered as light intensity, light quality, and/or photoperiod control on plant growth and development. Effects of supplementary blue or red LED radiation with lower light intensity on growth of Ageratum (Ageratum houstonianum Mill., cv. Blue Field), African marigold (Tagetes erecta L., cv. Orange Boy), and Salvia (Salvia splendens F. Sello ex Ruem & Schult., cv. Red Vista) were discussed during sunrise and sunset twilight in the experiment. METHODS AND RESULTS: Supplementary lighting by blue and red LEDs for 30 (Treatment B30; R30) or 60 (Treatment B60; R60) min. per day were established in greenhouse conditions. Photosynthetic photon flux for supplementary radiation was kept at $15{\mu}mol\;m^{-2}\;s^{-1}$ on the culture bed. Natural condition without supplementary light was considered as a control. The highest shoot and root dry weights were shown in African marigold exposed by red light for 60 min. per day. Supplementary blue and red lighting regardless of the radiation time significantly stimulated development of lateral branches in African marigold. Stem growth in Ageratum and Salvia seedlings was significantly promoted by red radiation as well as natural light. CONCLUSIONS: Extending of the radiation time at sunrise and sunset twilight using LEDs stimulated reproductive growth of flowering plant species. Different characteristics on growth under supplementary blue or red lighting conditions were also observed in the seedlings during supplementary radiation.

765kV 송전선로 낙뢰고장 분석 및 대책 (Analysis and Countermeasure of Lighting Fault on 765kV Transmission Lines)

  • 민병욱;이성학;김호기;강연욱;방항권;박재웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.337-338
    • /
    • 2008
  • KEPCO has built, for the first time in the world, 765㎸ double circuit transmission lines which use vertically arranged phase conductor, while 765㎸ transmission lines in other countries are single circuit lines and use horizontally arranged phase conductor. System operating voltage, switching overvoltage, and lightning overvoltage were considered in determining the air gap. Recently, however, lightning outage rate of some 765㎸ transmission lines in KOREA shows that it is more than what is expected. Lightning fault of 765㎸ transmission lines is mostly single phase grounding fault which can be reclosed. But it still needs to be carefully managed, for the bulk system like 765㎸ transmission lines have huge effects on whole power system. This paper introduces analysis and countermeasure of KEPCO's 765㎸ transmission line lightning outage.

  • PDF

가정용 전기기구의 효과적인 뇌서지 보호기법 (Effective Protection Methods of Household Electric Appliances. from Lightning Surges)

  • 이복희;강성만;엄주홍;이수봉;길형준;구본완;안창환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권3호
    • /
    • pp.149-156
    • /
    • 2004
  • This paper deals with the effective protection method for the household electric appliances against lightning surges invading from the Power lines. Direct or induced lightning is the main cause of the breakdown of household electric appliance. The most effective protection method is to install SPDs(surge protective devices) at household electric appliances. If SPDs were not installed at most household electric appliances, it is necessary to install SPDs on the mains. Therefore the propagation aspect and protection methods of lighting surges coming into household electric appliances through the mains was experimentally investigated. The in actual-sized test circuits results of protection method for 8 household electric appliances including computer monitors and TV set could be summarized as follows: The breakdown characteristics of household electric appliances from lightning surges were significantly changed with the their input impedance. Namely, the types of input impedance are classified into infinite, resistive or inductive impedances. Especially, the monitor for computer with inductive input impedance from lightning surges was relatively weak against lightning surges. It was confirmed that the self inductance of branch circuits on the mains have protection effect for household electric appliances against lightning surges invading from the power lines. Also the varistors installed at cabinet panel or circuit-breaker were more effective than multi-tap outlet with varistors. When installed varistors in cabinet panel and multi-tap outlet together, the surge protection effect is much more excellent in technical and economical aspects.

공연장 LED 조명시스템 구성의 경제성 평가에 관한 연구 (A study on Economic Evaluation of the Theater Stage Lighting System Using LED)

  • 이광모;안경석;구승환;한학수;최성진
    • 한국콘텐츠학회논문지
    • /
    • 제15권6호
    • /
    • pp.43-53
    • /
    • 2015
  • 본 연구는 할로겐 조명설비 대비 LED 조명시스템 구성의 경제성을 분석하였다. LED기구의 조명 경제성 평가를 위해 WEELS 2011를 사용하여 공연장 무대조명 시스템을 LED로 설계했을 경우, 공연장의 크기와 조명기구의 종류별 현재 가치와 연간비용, 면적별 연간비용을 분석하였다. 또한 소비에너지의 비교를 위해 면적당 소비 전력, 면적당 소비 전력량, 이산화탄소 배출량을 비교 분석하였다. 분석결과, 할로겐 조명기에 비해 LED 조명기의 연간비용이 매우 저렴하며 현재가치는 매우 높은 것을 알 수 있다. 하지만 LED 조명기의 초기 설비비가 약 200% 가까이 큰 것을 알 수 있다. LED 조명기구는 할로겐 조명기구에 비해 초기 시설비가 비싸지만 조명률의 값이 크고, LED의 상각년수(30년)가 할로겐의 상각년수(2년)보다 길기 때문에 연간비용에서 차이가 줄어드는 것을 알 수 있다. 향후 LED 조명기의 단가가 낮아지는 추세를 감안하면 할로겐 조명기보다 연간비용이 더 낮아 질 수 있다는 것을 알 수 있다. 그리하여 3차년도에 진입할 경우 비용 지출이 역전되는 것을 알 수 있었다.

사무용 건축물의 자연채광 설계 및 시공사례 연구 (A case study on design and construction of daylighting system of office building)

  • 김일호;최용준;박경우;이성진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.59.2-59.2
    • /
    • 2010
  • Throughout history, daylight has been a primary source of lighting in buildings, supplemented originally with burned fuels and more recently with electrical energy. Before daylight was supplemented or replaced with electric light in the late 19th-century, consideration of good daylight strategies was essential. As we entered the mid-20th-century, electric light supplanted daylight in buildings in many cases. Fortunately, during the last quarter of the 20th-century and early years of this century, architects and designers have recognized the importance and value of introducing natural light into buildings. There are many simple strategies that can enhance daylighting and reduce the need for electric lights. Good quality daylight is always welcome, but remember that the electric lights must be dimmed or shut off in order for daylighting to save energy. We designed and built mirror systems and vertical daylighting devices to improve daylight condition of office buildings in bad condition because urban density is getting higher. This case study aims to analysis the principles and characteristics of mirror systems and vertical daylighting devices and selected the method that can improve constructability. The results of this study are going to use the back data to set-up the design standards. Hereafter we're going to progress the performance test and product the design manual to improve applicability of daylighting systems at design phase.

  • PDF

Optimum Control of a Photoelectric Dimming System in a Small Office with a Double Skin Envelope

  • Kim, Soo Young;Yum, Sung Kon
    • Architectural research
    • /
    • 제7권2호
    • /
    • pp.47-54
    • /
    • 2005
  • A photoelectric dimming control system for a small private office space with a double skin envelope system was analyzed for the purpose of examining optimum control performances under a variety of daylight conditions. Computer simulations were performed for the three different photosensor types positioned at the center of ceiling in the space. They were applied in both a south and north-facing room. Daylight conditions were a fixed horizontal venetian blind on an external envelope and a retractable shading device on an internal envelope under a clear, intermediate and overcast sky at different times of a day and year. Partially-shielded photosensors provided good control performances providing the required electric light output under clear and intermediate sky conditions. Unshielded photosensors failed to provide necessary illuminance levels producing less electric output and fully-shielded photosensors generally provided excessive light output. Reasonable electric lighting energy savings were achieved except under overcast sky conditions where the control system did not contribute to energy savings due to the less daylight through envelopes. The retractable shading device covering 50% of the internal envelope reduced energy savings up to 19.62%, but the workplane illuminance levels were maintained within recommended ranges. The coefficients of determination between workplane illuminance and photosensor illuminance due to daylight ranged from 0.74 to 0.98. Partially-shielded conditions provided best correlations and the north-facing room yielded stronger correlation than the south-facing room.

발광형 COS조작봉의 안전작업 효과 분석 (The study of the COS control stick with lighting equipment)

  • 최명호;지용헌;김동식;이순배;최상준;정은영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2138.1_2139.1
    • /
    • 2009
  • COS 조작봉은 선로의 사고나 설비교체 또는 수리 등이 필요할 때 활선상태에서 COS를 개폐하기 위한 장비로서 보통 절연특성 및 강도가 우수하고 경량소재인 FRP(Fiberglass Reinforced Plastics)로 제작된다. 따라서 특고압 선로에서 작업 중 안전사고를 예방하기 위해 사용되는 장비인 만큼 안전거리 확보와 작업의 편리성을 고려하여 직접 조작봉을 연장하여 사용할 수 있도록 다단으로 제작되며, 조작봉의 크기는 작업조건에 따라 길이를 선택하여 사용할 수 있도록 2, 4, 6m급 등 길이에 따른 종류별로 생산되고 있다. 이러한 COS 조작봉의 사용특징은 장소와 시간에 관계없이 사용이 가능해야 하고, 특정한 사정에 의해선 작업자 혼자서 사용할 수 있도록 조작봉과 일체된 조명장치의 필요성이 항상 제기되어 왔던 문제이다. 본 논문에서는 이러한 문제점에 주안을 두고 조작봉과 일체된 전계검출에 의한 발광동작을 제어할 수 있는 발광형 COS 조작봉에 대해 각각의 구성별 요소들을 분석하고자 한다.

  • PDF

800kV급 GIS의 모델차단부용 스페이서의 형상설계 (Shape Design of A Spacer for 800kV GIS Interrupter)

  • 신영준;장기찬;박경엽;정진교;송원표;강종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1639-1642
    • /
    • 1994
  • The severe conditions such as rated voltage of 800kV, gas pressure of $5kg/cm^2$ and rated lighting impulse withstand voltage of 2400kV were adopted for the design of spacers in the 800kV GIS to give a sufficient design margin. The design criteria on the maximum electric field strength of the center conductor and the insulator surface were established by considering the insulator surface characteristics, electrode area and surface effects in the unequal electric field strength of the given gap. The design parameters such as inter/outer envelope degree, thickness, inter/outer inserts, triple junction gap were determined by calculating the electric field using FLUX-2D program package and by referring to the published papers. The mechanical stress analysis was conducted on the feasible model spacers that showed good electric field distributions to confirm the sufficient mechanical design margin. The 800kV spacer designed as described above is now in the process of manufacturing.