Assessment of 23 kV Capacitive Coupler for On-line Partial Discharge Measurements

  • Jeong, J.Y.;Kang, D.S.;Sun, J.H.;Heo, J.C.;Park, C.H.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.123-130
    • /
    • 2009
  • The partial discharge (PD) measurement is a very effective method to assess the winding insulation condition of high-voltage machines, since most of the insulation failure processes are directly or indirectly caused by PD. On-line PD measurements, which can detect insulation defects of winding in the early stages on rotating machines in operation, have been accepted as the most important technique. The epoxy mica capacitive coupler is currently and extensively used for on-line detection of PD pulses of high-voltage rotating machines. To evaluate the feasibility of developing a capacitive coupler that is easier to manufacture at a lower cost compared to epoxy mica couplers, a 100pF capacitive coupler made of ceramic material is designed, fabricated and tested for on-line PD measurements of 23 kV electrical machines. A series of electrical tests and accelerated aging tests are performed on the ceramic coupler to evaluate the performance requirements, long-term reliability and thermal stability for in field application. The test results show that the newly developed ceramic coupler provides equal and improved performance at a lower cost compared to epoxy mica couplers, and estimated voltage life is anticipated to surpass 100 years.

X7R용 적층 칩 세라믹 캐패시터 조성의 희토류 첨가에 따른 유전 특성 (The Effect of Rare-Earth Additives on Dielectric Properties of X7R MLCC Composition)

  • 이석원;윤중락
    • 한국전기전자재료학회논문지
    • /
    • 제16권12호
    • /
    • pp.1080-1086
    • /
    • 2003
  • Effects of E$_2$O$_3$. HO$_2$O$_3$ and Dy$_2$O$_3$ addition on dielectric properties of non-reducible BaTiO$_3$ based X7R dielectrics with Ni electrode have been studied in a reduced atmosphere. As the content of rare-earth with E$_2$O$_3$. HO$_2$O$_3$, Dy$_2$O$_3$ was less than 3wt%, The TCC(Temperature Capacitance Change) and insulation resistance characteristics were improved by compensate the oxygen vacancies due to occupy either the Ba or Ti site. We developed the composition of X7R (EIA standard) for higher capacitance MLCC which had high reliability electric properties by the addition of Er ion into BaTiO$_3$ + MgO + Y2O$_3$ + MnO + (Ba$\sub$0.4/Ca$\sub$0.6/)SiO$_3$ composition.

PD 분포 분석에 의한 견인전동기 고정자 코일의 열화도 분류에 관한 연구 (Classification of stator coil degradation of traction motor by PD signal distribution analysis)

  • 박성희;임종호;장동욱;박현준;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1183-1186
    • /
    • 2004
  • Degradation and insulation failure of traction motor depend on the continuous stress imposed on it. And knowing on insulation condition is important thing for safety operation of EMU(electric multiple unit). In this paper, PD(partial discharge) characteristics for degradation analysis of stator coil is studied. For PD data acquisition, two models are made; one is normal condition coil, the other is aged condition coil. And PD data for discrimination were acquired from PD detector. And these data making use of a computer-aided discharge analyser, statistical and other discharge parameters is calculated to discrimination between different discharge sources. And also these parameter is applied to classify PD sources by neural networks. Neural Networks has good recognition rate for degradation of stator coil.

  • PDF

나노층상실리케이트가 충진된 에폭시-나노콤포지트의 열적특성 연구 (Thermal Characteristics of Epoxy-Nanocomposites filled Several Types Nano Layered Silicate Particles)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제21권8호
    • /
    • pp.749-754
    • /
    • 2008
  • A large number of studies on the various characteristics of epoxy-layered silicate nanocomposites, such as electric and mechanical, morphology have been conducted and contributed to improve their characteristics. However, studies on the effects of its thermal conductivities in the thermal properties are not enough, even though there are some excellent evaluations for its insulation performances. Thermal properties will cause thermal degradation and significantly affect the reliability of these epoxy-layered silicate nanocomposites. In the results of the analysis of epoxy-layered silicate nanocomposites $T_g$ for various types of organoclays (10A, 15A, 20A, 30B, and 93A), it showed an excellent thermal property of 10A. Also, it represented low values in storage modulus and mechanical Tan (Delta) at a high temperature section 140$^{\circ}C$ and excellent thermal properties due to its movement to the high temperature section in the case of the property of 10A in the measurement of DMA elastics and mechanical losses. In the results of the measurement of thermal conductivities, power ultrasonic applications represented a significant increase in thermal conductivities in the case of the applications of power ultrasonic and planetary centrifugal mixers. Based on these results, it is necessary to perform related studies because it can be applied as useful materials for future power facilities applications in mold and impregnate insulation.

가교폴리에틸렌 지중케이블에서 화상계측을 이용한 수트리 열화현상 분석 (The Analysis of Water Tree Degradations in Underground Distribution Cables Using Image Measurement)

  • 김덕근;임장섭;이진;이준웅;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.19-23
    • /
    • 1998
  • Water tree degradations have been considered as one of the most important causes of failure in underground distribution cables with polymeric insulation. Water tree growth is a preliminary step in the sequence of electrical tree initiation and electrical breakdown of the insulation. In this paper, needle electrode is made use of the etching methods and the pellet type specimen is made to observe the water tree in succession. In previous methods are able to observe the tree degradations without cutting and dyeing. The water tree image is recorded on VTR with CCD camera. The tree length of X, Y axis direction and aging area(treeing area) are calculated with image measurement. As a result of this study, water tree is observed by non-destructive method. Electrical tree is initiated from needle electrode tip only but water tree is initiated from total area of water electrode. Electrical tree owing to water treeing is initiated at low electric field and grown with discontinuously. Namely, water tree is shown up a different characteristics of tree growth.

  • PDF

ANFIS 분류기법을 이용한 부분방전원의 분류 (PD classification by using ANFIS method)

  • 박성희;윤재훈;김병철;임기조;강성화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.467-467
    • /
    • 2007
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE (cross-linked polyethylene). And the size of the specimen is $7^*5^*7mm^3$. Distance between needle and plane is 2 mm. Voltages applied to acceleration test are ranged 12 to 15 kV. And distribution characteristic of degraded stage is studied too. By PD detecting and data processing, discharge data was acquired from PD detecting system (Biddle instrument). The system presents statistical distribution of phase resolved. Moreover, the processing time of electrical tree is recorded to know the speed of degradation according to voltage. Finally, it's used PD classification by ANFIS method.

  • PDF

거칠기에 따른 반도전-절연 계면층에서 접착특성과 절연성능 (Adhesion and Electrical Performance by Roughness on Semiconductive-Insulation Interface Layer of Silicone Rubber)

  • 이기택;황선묵;홍주일;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.78-81
    • /
    • 2004
  • In this paper, the effect of adhesion properties of semiconductive-insulating interface layer of silicone rubber on electrical properties was investigated. Surface structure and adhesion of semiconductive silicon rubber by surface asperity was obtained from SEM and T-peel test. In addition, ac breakdown test was carried out for elucidating the change of electrical property by roughness treatment. From the results, Adhesive strength of semiconductive-insulation interface was increased with surface asperity. Dielectric breakdown strength by surface asperity decreased than initial Specimen, but increased from Sand Paper #1200. According to the adhesional strength data unevenness and void formed on the silicone rubber interface expand the surface area and result in improvement of adhesion. Before treatment Sand Paper #1200, dielectric breakdown strength was decreased by unevenness and void which are causing to have electric field mitigation small. After the treatment, the effect of adhesion increased dielectric breakdown strength. It is found that ac dielectric breakdown strength was increased with improving the adhesion between the semiconductive and insulating interface.

  • PDF

폴리머 절연암을 이용한 송전선로 전압 승압에 관한 연구 (A Study on the Voltage Upgrading of Transmission Lines using Polymer Insulation Arm)

  • 이원교;이정원;강연욱;이동일
    • 한국전기전자재료학회논문지
    • /
    • 제22권10호
    • /
    • pp.870-878
    • /
    • 2009
  • The large increase in the use of electricity has resulted in an ever-growing electric power demand. It has created the need for the construction of power transmission facility located close to the load centers and it also has to require wide right-of-way and large lots, that are not always available, for especially the installation of the towers. The difficulties in acquiring right-of-way have put pressure on energy companies to either upgrade a line on an existing right-of-way to higher voltage or build a new line on a narrow right-of-way. This paper presents the design of a compact tower with polymer Insulation arm, in order to reduce the separation between phases. the compact tower can be built on a narrow right-of-way. the compact tower can be designed based on 345 kV Tower regarding electrical clearances and right of way, therefore the conventional 154 kV Tower can be upgrading transmission line voltages have moved to 345 kV levels.

PCB의 이온-마이그레이션에 영향을 미치는 주요요인 (Main Factors that Effect on the Ion-Migration of PCB)

  • 장인혁;김정호;오길구;이영주;임홍우;최연옥
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제16권3호
    • /
    • pp.202-207
    • /
    • 2016
  • Purpose: The purpose of this study is main factors (environmental conditions, pattern spacing, pattern material) that effect the ion-migration of PCB. Methods: Recently, the electronic components are becoming more high density of electronic device, so that electronic circuits have smaller pitches between the patten and more vulnerable to insulation failure. so the reliability of electric insulation of device has become an ever important issue as device contact pitches of pattern. Usually, ion-migration occurs in high temperature and high humidity environment as voltage is applied to the circuit. Under high temperature and high humidity, voltage applied electronic components respond to applied voltages by metals's electrochemical ionization and a conducting filament forms between the anode and cathode across a nonmetallic medium. This leads to short-circuit failure of the electronic component. Results: we studied ion-migration that occurs in accordance with the main factors (environmental conditions, pitches, pattern material). The PCB pattern material was made by two different types of material (free solder, OSP) for this research and pitches of pattern is 0.15mm, 0.3mm, 0.5mm. PCB was experimented in the environmental conditions (high temperature $120^{\circ}C$, high temperature and high humidity $85^{\circ}C$, 85%RH) and was analyzed for ion-migration through the experiment results. Conclusion: We confirmed that environmental condition, pitches of pattern, pattern material had effect on ion-migration of PCB.

가공송전선로 애자 적용실태와 향후 전망 (Insulator application and prospect)

  • 김우겸;민병욱;김태영;위화복;최진성;이북창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.327_328
    • /
    • 2009
  • The insulator being used for transmission line is to mount the charged conductor on the tower or other supports. The insulators are classified according to its material: porcelain, glass and polymer. Polymer insulators are also called as composite insulator or non ceramic insulator (NCI). Insulators are a major element of a power transmission system. Since a faulty insulator can lead to a wide spreading blackout, it must have sufficient mechanical and electrical strength. It must be durable, have high electrical insulation and be able to withstand a leakage current. It must also be able to withstand the toughest weather conditions. In Korea, porcelain insulators have been used widely. However, to make compact equipment and keep up with global trends, we have enhanced domestic production of polymer insulator and are encouraging its applications. Accordingly, this thesis will look at types of insulators, use and trends, and prospects of insulators application in the field.

  • PDF