• Title/Summary/Keyword: Electric home

Search Result 365, Processing Time 0.025 seconds

Power demand pattern analysis for electric appliances in residential and commercial building (주택 및 사무용 빌딩 내 전기기기의 전력 수요 패턴 분석)

  • Noh, Sung-Jun;Lee, Soon-Jeong;Lee, Sang-Woo;Kim, Kwang-Ho
    • Journal of Industrial Technology
    • /
    • v.30 no.A
    • /
    • pp.9-15
    • /
    • 2010
  • Recently, Smart Grid is a emerging topic in power and communication industry. Smart Grid refers to a evolution of the electricity supply infrastructure that monitors, protects, and intelligently optimize the operation of the interconnected elements including various type of generators, power grid, building/home automation system and end-use consumers. In order to successful implementation of Smart Grid, energy management function will be the key factor that coordinates and optimally controls the various loads according to the operating condition and environments, and the load patterns in residential and commercial building will be required as fundamental element for load management. In this study, we collects many types of energy usage data of electric appliances, analyze their load curves, and make the general load patterns for electrical appliance.

  • PDF

Cost-effective Power System with an Electronic Double Layer Capacitor for Reducing the Standby Power Consumption of Consumer Electronic Devices

  • Park, Kyung-Hwa;Yi, Kang-Hyun
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.362-368
    • /
    • 2013
  • Commercial home appliances using remotely controlled systems consume electric power while in standby mode to prepare for receiving a remote turn-on signal. The proposed power system can significantly reduce standby power consumption without increasing cost. Furthermore, since a Electronic Double Layer Capacitor (EDLC) is used as an auxiliary power storage element, the life cycle is longer and system reliability can be better than with existing approaches. When the energy of the EDLC is not sufficient for turning on the appliance, the power system charges the EDLC without affecting the main system. The proposed power system is verified with a commercial LCD TV and a 3.93mW standby consumption is obtained. This standby consumption can be regarded as zero standby equipment according to the IEC-62031 standard.

P/M Aluminium Automobile Parts in Sumitomo Electric Ind. Ltd.

  • Akechi, Kiyoaki
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 1997.04a
    • /
    • pp.5-5
    • /
    • 1997
  • Rapidly-solidified P/M aluminium alloys for automobile and home appliance industries were developed. Rapidly-solidification made it possible to refine microstructures and to expand the range of alloy composition. For example, Al-Si alloys containing transition metal have lower thermal expansion coefficient, more excellent wear resistance, higher strength, and better machinability than those of conventional aluminium alloys. Therefore, in Japan, the technologies on powder-extrusion and powder-forging of aluminium alloy powders are developed for fifteen years, and applied to several parts, such as cylinder liners of motor cycle engines, rotors and vanes of compressors for car air conditioner, oil pump rotor for racing car, and so on. In this presentation, applications for automobile are mentioned. In particular, cylinder liners made of particle-dispersed composites with fine alumina and graphite are in detail described.

  • PDF

Reliability test design for Electric and movement apparatus of recliner sofa for home use (가정용 리클라이너 소파의 전기 및 기구부에 대한 신뢰성시험 설계)

  • Jang, In-Hyeok;Hyung, Jae-pil;Lim, Hong-Woo;Choi, Youn-Ok
    • Journal of Advanced Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.259-265
    • /
    • 2018
  • In this paper, we propose a test method to evaluate the reliability of the recliner sofa in the early stage of production. In order to develop the test method, we analyzed the failure mechanism occurring in the field and designed the performance test, environmental test, accelerated life test methods based on the analysis of failure mechanism. The failure mechanism is reproduced by applying the designed test. The reliability of the recliner sofa can be verified at the production stage through the proposed test method.

Content analysis of video lecture on making electric car for prospective teachers (예비 교사를 대상으로 한 전기 자동차 만들기 동영상 강의 컨텐츠 분석)

  • Lee, Eun-Sang
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.07a
    • /
    • pp.443-446
    • /
    • 2021
  • 이 연구의 목적은 온라인 상에서 수행된 실습 수업 방식을 분석하는데 있다. 이를 위해 연구자는 예비 교사를 대상으로 '전기 자동차 만들기'수업 주제로 실습 수업을 설계하였으며, 온라인 동영상 강의 컨텐츠 3편을 제작하였다. 동영상 강의 컨텐츠 제작을 위해 교수용 홈페이지 제작, 수업에서 사용할 동영상 제작, 과거 촬영하거나 제작해 두었던 동영상 준비, 실습 재료 준비, 실습 활동 관련 교과서 준비 등 다양한 교수학습자료를 사전에 준비하였다. 동영상 강의 컨텐츠는 CODTRA 분석 방법을 이용 하였으며, 분석 코드는 '동영상에서 제시된 교수학습자료'와 '교수자가 행하고 있는 상태'이었다. 분석 결과는 CODTRA 다이어그램에 의해 분석 코드를 시간에 따라 도식화하여 도시하였다. 이 연구 결과는 중등학교의 기술 교과나 공업계 교과에서 온라인 실습 수업을 위한 동영상 강의 컨텐츠를 제작하고자 하는 교수자에게 참고할 수 있는 자료로 활용될 수 있을 것이다.

  • PDF

A Study on Voltage Sag Considering Real-Time Traffic Volume of Electric Vehicles in South Korea

  • Go, Hyo-Sang;Kim, Doo-Ung;Kim, Jun-Hyeok;Lee, Soon-Jeong;Kim, Seul-Ki;Kim, Eung-Sang;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1492-1501
    • /
    • 2015
  • This paper analyzes the effect of voltage sag on distribution systems due to the connection of Electric Vehicles (EVs). In order to study the impact of the voltage sag on the power system, two scenarios have been selected in this paper. The distribution system and EVs are modeled using the Electro Magnetic Transients Program (EMTP). The numbers of EVs are predicted based on the number of vehicles in distribution system of Seoul. In addition, the number of EVs is set up using real-time traffic in Seoul to simulate Scenario I and II. The simulation results show that voltage sag can occur if the distribution system has more than 30% of the total number of vehicles.

A Study on the Application Cases Analysis of ESS(Energy Storage System) to Electric Power System (에너지 저장 시스템의 전력계통 적용 사례 분석)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.1
    • /
    • pp.53-58
    • /
    • 2016
  • Because a progressive tax of home electricity rates is charged and a continuous rise of industrial electricity rates is expected in order to solve the global warming, the high oil prices and the serious power shortage problem, the efforts to apply the energy storage systems which can significantly improve the energy usage efficiency to the smart grid are trying newly. In this study, characteristics of the secondary battery which can be used as energy storage devices, the structure and operation principle of a lithium-ion battery, and the concept of energy storage systems are research and analyzed. In addition, in this paper, the base technologies which are required to apply to the energy storage system to electric power system are established by studying about installation location and application methodology of energy storage system to electric power system.

A Case of Resuscitation of an Electrocuted Child by a 119 Paramedic (감전으로 심정지된 소아환자 소생 1례)

  • Lee, Jae-Min;Kim, Dae-Won;Yun, Hyeong-Wan
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.135-140
    • /
    • 2020
  • The purpose of this study was to prevent electric shock to children. children are at high risk of electrocution by accidents. In the present case, a 2-year-old child was electrocuted after inserting metal chopsticks into a home outlet. In this case, professional advanced cardiac life support (ACLS) was properly performed by a 119 paramedic, resulting in the return of spontaneous circulation (ROSC) in the child. There are very few successful cases of resuscitation of patients involved in electric shock accidents in Korea, and we report a case of ROSC and discharge and proper resuscitation by a 119 paramedic.

Impact of Electric Vehicle Penetration-Based Charging Demand on Load Profile

  • Park, Woo-Jae;Song, Kyung-Bin;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.244-251
    • /
    • 2013
  • This paper presents a study the change of the load profile on the power system by the charging impact of electric vehicles (EVs) in 2020. The impact of charging EVs on the load demand is determined not only by the number of EVs in usage pattern, but also by the number of EVs being charged at once. The charging load is determined on an hourly basis using the number of the EVs based on different scenarios considering battery size, model, the use of vehicles, charging at home or work, and the method of charging, which is either fast or slow. Focusing on the impact of future load profile in Korea with EVs reaching up 10 and 20 percentage, increased power demand by EVs charging is analyzed. Also, this paper analyzes the impact of a time-of-use (TOU) tariff system on the charging of EVs in Korea. The results demonstrate how the penetration of EVs increases the load profile and decreases charging demand by TOU tariff system on the future power system.

A Study on the Safety of Organic Compound Type Thermal Fuse (유기물가용체형 온도퓨우즈의 안전성에 관한 연구)

  • 황명환;정영식
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.1
    • /
    • pp.53-59
    • /
    • 1996
  • To protect the damages or the disasters caused by overheating of industrial electric equipments or electric home appliances, a temperature sensitive thermal fuse is generally used in those equipments. Thermal fuses cutoff the current flow when the temperature of the electric equipments are abnormally overheated and over the certain temperature. Therefore thermal fuse is one of the most important elements in the sense of safety. Thermal fuses are classified into two types according to thermally sensitive materials, a low temperature melting alloy and an organic chemical compound. Domestic products of thermal fuses are now only with an organic chemical compound. Domestic products tested by using cutoff test and aging test etc. are satisfied UL specification. It's shown that the accuracy and the precision of the domestic products are as good as those of the overseas products obtained UL mark. However, some of domestic products show the reclosing problem which is mainly related the safety. This problem should be solved to make the reliable thermal fuses. In this paper, our Interest is to find out the causes of reclosing. In the comparison between thermally sensitive materials occurred reclosing and those occurred no reclosing, the test effects show that the characteristics of emitting heat and absorbing heat are different.

  • PDF