• 제목/요약/키워드: Electric heating equipment

검색결과 46건 처리시간 0.027초

고주파 가열 장비를 활용한 터빈로터 휨 교정수식모델 개발 (Development of Turbine Rotor Bending Straightening Numerical Model using the High Frequency Heating Equipment)

  • 박준수;현중섭;박현구;박광하
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권2호
    • /
    • pp.269-275
    • /
    • 2021
  • The turbine rotor, one of the main facilities in a power plant, it generates electricity while rotating at 3600 RPM. Because it rotates at high speed, it requires careful management because high vibration occurs even if it is deformed by only 0.1mm. However, bending occurs due to various causes during turbine operating. If turbine rotor bending occurs, the power plant must be stopped and repaired. In the past, straightening was carried out using a heating torch and furnace in the field. In case of straightening in this way, it is impossible to proceed systematically, so damage to the turbine rotor may occur and take long period for maintenance. Long maintenance period causes excessive cost, so it is necessary to straighten the rotor by minimizing damage to the rotor in a short period of time. To solve this problem, we developed a turbine rotor straightening equipment using high-frequency induction heating equipment. A straightening was validated for 500MW HIP rotor, and the optimal parameters for straightening were selected. In addition, based on the experimental results, finite element analysis was performed to build a database. Using the database, a straightening amount prediction model available for rotor straightening was developed. Using the developed straightening equipment and straightening prediction model, it is possible to straightening the rotor with minimized damage to the rotor in a short period of time.

천연가스.지역난방 수요관리 투자사업의 회피비용 산정기법 개발 및 적용 (Methodology and Application of Avoided Cost Calculation for Natural Gas and District Heating DSM programs)

  • 최봉하;박상용;이덕기;박수억
    • 산업공학
    • /
    • 제20권3호
    • /
    • pp.353-362
    • /
    • 2007
  • This paper proposed the calculation method of the avoided cost for natural gas and district heating DSM programs. And the proposed method is applied to real DSM programs. The avoided cost for natural gas consists of commodity avoided cost, supply equipment avoided cost, storage equipment avoided cost, and electric power avoided cost. In case of the district heating, avoided cost consists of heat generation equipment avoided cost, heat energy avoided cost, environment avoided cost, and electric power avoided cost. This method can be used to evaluate the benefit of DSM programs quantitatively in cost. Therefore, this method can contribute to make the cost-effectiveness evaluation system and to operate the DSM programs for natural gas and district heating effectively.

심야전기보일러 대체용 공기열 히트펌프 성능평가 (A Study of Air-source Heat Pump Performance Analysis for Replacing Night Time Electric Heating Boiler)

  • 조종영;정훈;이철희
    • 한국기계기술학회지
    • /
    • 제13권3호
    • /
    • pp.81-85
    • /
    • 2011
  • The night time electric cost is cheaper due to electric supply and demand policy in Korea from 1985. Currently about 900,000 customers are using night time electric heating boilers and this causes shift of peak demand time to night in winter and increase of deficit spending. To solve this problem, replacing night time electric heating boiler by air-source heat pump using night time electricity has been proposed. An air-source heat pump can provide efficient heating equipment especially in a warm climate. For estimating the night time electric heat pump COP(Coefficient of Performance), Korean Standard KS C 9306:2010 and European Standard EN-14511:2004 is available. SCOP(Seasonal COP) using European weather bin data is also calculated. SCOP is not available yet but European Committee for Standardization will establish a standard in the near future. The evaluation result show that the replacing night time electric heating boiler by heat pump can be possible.

전기가열장치를 이용한 연약지반개량 (Improvement of Soft Ground using Electric Heating Equipment)

  • 한희수;임은상;이금성;장동훈
    • 한국지반환경공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.5-12
    • /
    • 2014
  • 본 논문은 심층연약지반 개량용 전기가열장치를 개발하여 경기도 화성시 인근 연약지반에 적용한 것이다. m당 1 kW의 전기를 소비하는 니켈-크롬선으로 구성된 길이 4.0 m의 전기가열장치를 지표하 3.5~6.5 m 사이에 설치하여 48시간의 지반가열을 2회, 총 96시간 실시하였으며, 온도계와 압력계를 지표하 5.0 m 지점에 매설하여 지반가열에 의한 온도 및 증기압 변화를 측정하였다. 실험결과 가열원으로부터 횡방향 거리의 온도분포 및 선단지지력의 변화는 이차함수를 나타내었으며, 둘 다 R2값은 1로 산정되었다. 또한, 전기가열로 인해 수증기가 배출됨에 따라, 함수비 및 간극수압이 감소함을 관찰할 수 있었다.

선풍기의 운전 상황별 발열특성 및 전류신호 검출 (Detection of Current Signal and Thermal Characteristics of Electric Fan Operated in Various Situations)

  • 김두현;이흥수
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.20-27
    • /
    • 2014
  • Cooling equipment is the frequent occurrence of fire despite the absence of the heating element. National fire statistics in 2013 show that a total of 263 fires occurred in the cooling equipment and the number of electric fan has 145 fire cases. This is accounted for 55.1% of the whole. Electric fan is the electrical appliance that the heat is generated on the winding wire and the iron core. If such characteristic is not controled properly, fire would break out at the electric fan. also there is a gap filled with an insulator between connection terminals of the capacitor in the electric fan. But in case that the gap on the capacitor is covered with some conductive material such as dust, there would be a fire as well caused by electrical heating locally. Although many studies related with those have been conducted, electric fan fire is continuously occurred. In this study, thermal characteristics and current signal in various conditions such as the heat generation of windings including iron cores of the motor and the dielectric breakdown of terminals on the capacitor connected to the motor were detected. In order to measure the maximum temperature, "third level" wind velocity button was pushed and the time selection switch to "continuation" was set. Analyzed data would be available for the fire safety of the electric fan.

우리 쌀의 밥맛 향상을 위한 취반기술 개발 연구;제2보 탑라이스 쌀 품종의 취반특성 연구 (Cooking Techniques to Improve the Taste of Cooked Rice;Optimal Cooking Conditions for Top Rice Cultivars)

  • 한귀정;박희정;이혜연;박영희;조용식
    • 한국식품조리과학회지
    • /
    • 제24권2호
    • /
    • pp.188-197
    • /
    • 2008
  • This study was carried out to determine the optimal cooking conditions for various rice cultivars (Ilpoom, Saechucheong, Sindongjin, and Sura-top rice) using trial preparations with different soaking times (0, 30, and l20min) and cooking equipment (electric pressure cookers, electric cookers, gas pressure cookers, iron pots, and stone pots). In adddition, the texture and sensory characteristics of the rice prepared with the electric pressure cookers, gas pressure cookers, and stone pots were analyed. The results showed that the moisture, amylose and physicochemical compositions of the four rice varieties were similar. According to RVA, the Sura, cultivar had generally high viscosity, and the Ilpoom, cultivar presented the highest hot and peak viscosities. Saechucung had the highest initial gelatinizing temperature and Sindongjin showed the greatest setback. The optimal amounts of added water as well as heating conditons were dependent on the rice varieties, soaking times, and cooking equipment. A longer soaking time reduced the hardness of the cooked rice, amount of added water, and the heating time. The pressure cooking equipment provided the best cooked rice texture, reduced the affect of the soaking time, and decreased the heating time. In general, all the variaties of cooked rice had high overall acceptability, which tended to increase when the rice was soaked for 30min prior to cooking, had a 1.2-fold amount of water to rice added, and was cooked in the pressure equipment.

전기유도보일러의 발열효율개선을 위한 권선최적설계 (Optimal Design of a Coil for Improved Heating Efficiency of Electric Induction Boiler)

  • 김윤현;김솔
    • 한국산학기술학회논문지
    • /
    • 제20권3호
    • /
    • pp.476-482
    • /
    • 2019
  • 본 기후변화협약, 온실가스배출규제와 같은 규제적 규약들은 고효율 에너지 기자재 개발과 에너지의 효율적 이용을 촉진하는 촉매로 작용하고 있다. 에너지소비가 큰 분야 중 전열기기가 효율이 좋지 못한 편이다. 전기보일러는 히터에 물을 접촉시켜 순환시키는 방식을 주로 사용하고 있다. 기존 전기보일러를 활용할 경우 물의 미네랄이 고온의 히터와 접촉하여 탄화되어 흡착되는 과정에서 히터의 부식을 촉진시키고 히터의 효율을 저하시킨다. 이러한 이유로 에너지 효율이 높고, 전도나 대류가열보다 피가열물을 균일하게 가열시킬 수 있는 유도가열방식을 보일러에 적용시킨 전기유도보일러가 각광을 받고 있는데, 이 방식은 물이 담겨 있는 보일러 관로를 유도가열방식으로 가열하여 직접가열시 발생하는 문제를 해결시킬 수 있는 대안으로 인정받고 있다. 비교적 오랜 기간 유도가열에 대한 연구가 이루어졌음에도 불구하고 유도가열을 이용한 전열기술에 대한 연구결과는 그리 많지 않은 실정이다. 따라서 본 논문에서는 전기유도보일러의 발열효율을 개선하기 위하여 매개변수연구방법을 통하여 권선의 단면적, 권선의 수 및 권선의 겹수에 의한 영향을 유한요소법을 이용하여 해석하고 발열의 요소가 되고 있는 동손과 철손을 분석하여 발열을 극대화시킬 수 있는 권선설계방법으로 총손실이 최대가 되는 설계점을 찾는 방법을 제시하였다.

열병합시스템 경제성 평가 프로그램의 개발 및 적용에 관한 연구 (Development and Application of an Economic Assessment Program of Cogeneration Systems)

  • 박차식;김용찬
    • 대한기계학회논문집B
    • /
    • 제22권11호
    • /
    • pp.1547-1554
    • /
    • 1998
  • The object of this study was to develop an economic assessment program for the optimal design of the cogeneration systems composed of combining engine, generator, waste heat recovery exchanger, absorption chiller, and boiler, etc. The energy demand categorized by electric power, heating, cooling and water supply was determined by statistical data of the existing cogeneration systems. An economic assessment was performed by comparing the total cost of cogeneration system with that of non-cogeneration system. The total cost was evaluated by adding initial investment to operational cost considering efficiency of equipment, cost of equipment, fuel and electricity. To confirm the validity of the developed program, a hotel building with an area of $127,960m^2$ was selected, and the simulated results were compared with the measured data. The difference between the simulated and the measured values for the selected hotel building was approximately 12% for annual electric consumption.

전기가열장치를 이용한 표층지반개량 (Improvement of Shallow Soil Using Electric Heating Equipment)

  • 박민철;임은상;신백철;한희수
    • 한국지반공학회논문집
    • /
    • 제28권10호
    • /
    • pp.41-54
    • /
    • 2012
  • 본 논문은 전기가열장치를 이용한 표층지반 개량방법을 개발하기 위한 것으로, 현장 지반에 적합한 전기가열 장치를 개발하여 연구하였다. 전기가열에 의한 해성점토의 거동을 해석하기 위하여 실내실험을 하였으며, 실내시험 시 $70^{\circ}C$$110^{\circ}C$의 두 가지 온도를 이용하여 포화점토의 증발과 압축의 상호관계를 검증하였다. 또한 가열지반에 콘관입기를 이용하여 중장비의 주행성을 시험하였다. 나아가, 지반개량 및 강도변화 범위를 분석하기 위하여 현장실험을 하였다. 현장지반의 온도변화를 측정하였으며, 그 결과는 상용 프로그램(Temp/W) 해석치와 비교하였다. 또한 평판 재하시험을 이용하여 전기 가열된 현장지반의 지지력을 평가하였다. 전기 가열된 지반의 개량범위와 강도변화는 가열 온도와 시간에 의존하였다. 가열온도가 지하수를 증발시킬 수 있는 $100^{\circ}C$ 이상이면, 지지력과 침하량이 급격히 증가하였다. 지반의 지지력은 3배 이상 증가하였고, 가열지반은 많은 수증기를 배출하였다. 전기가열기 주변 약 20cm 범위의 흙은 완전 소결되었다.

연료전지 스택 폐열 활용 전동식 히트펌프 시스템 난방 성능 특성 연구 (Experimental study on heating performance characteristics of electric heat pump system using stack coolant in a fuel cell electric vehicle)

  • 이호성;김정일;원헌주;이무연
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.924-930
    • /
    • 2018
  • 본 연구의 목적은 수소연료전지 자동차의 난방부하 대응을 위한 스택 냉각수를 활용하여서, 전동식 히트펌프 시스템에 대한 난방성능 특성을 다양한 운전조건 변화에 대해서 고찰하는 것이다. 냉각수와 냉매(R-134a)와의 열교환을 위해서 판형열교환기를 적용하였고, 전동식 히트펌프 시스템에 적용되는 실내열교환기 입구의 공기온도와 압축기 회전수를 변화시키면서 난방 성능 특성을 분석하였다. 실내열교환기 입구 공기 온도 변화에 대해서 난방 성능은 거의 동일한 결과를 보이고 있는데, 이는 입출구 온도차와 공기 측 밀도의 변화가 균형을 이루었기 때문으로 판단된다. 반면, 히트펌프 시스템 효율(COP)의 경우, 난방 성능은 온도변화에 따라 동일하였지만, 유량 변화로 인하여서, 압축기 소모동력이 감소하였기 때문에, 실내열 교환기 입구 온도가 감소함에 따라서, 시스템 효율은 증가하는 경향을 보이고 있다. 추가적으로, EEV개도가 45%정도까지 열리는 구간에서는, 압축기 소모전력 감소하였기 때문에, 시스템 효율이 증가하였고, 그 이후에는 동일한 시스템 효율을 유지하는 것을 알 수 있었다. 압축기 회전수 변화 시에는 난방성능이 증가하면, 시스템 효율은 감소하는 경향을 보여주고 있다. 이러한 원인은 압축기 회전수 증가에 따른 유량의 증가로 판단된다. 향후, 열원으로 사용하는 냉각수에 대한 운전조건을 변화시켜가면서, 난방성능 특성을 분석하여, 전동식 히트펌프의 난방부하 대응을 위한 제어 방안을 연구하고자 한다.