• 제목/요약/키워드: Electric heating appliance

검색결과 8건 처리시간 0.028초

전기난방기구의 경제성 분석 비교 (Economic analysis of Electric heating appliances)

  • 김용하;이광성;남김현;박남철;우성민;김미예;임현성
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.448-452
    • /
    • 2006
  • Many kinds of electric heating appliance is used by user interface and desire. Far infrared ray heating system can use a kind of main heating appliance. This paper gives un saving amounts, energy curtailment money and payback period between far infrared ray heating system and existing electric heating appliance - EHP, electric air heater, electric radiator, electric floor heating system - from economy analysis.

  • PDF

LC 직렬공진에 의한 전기 수술기 개발 (Development of electric surgical machine by LC series resonance)

  • 이오걸;김태우;송호신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.153-157
    • /
    • 2002
  • Electricity living body formation operation appliance is using most imports until present. And, because electricity living body formation operation appliance is too expensive, it becomes burden to buy in small scale hospital. Also, problem that economical damage by income is added follows, Therefore, this treatise developed electricity living body formation operation appliance by home production, Ultra high frequency eruption circuit used LC circuit, and output frequency is possible to 8 [MHz], and output voltage amplified maximum 800 [V]. This operation appliance could display size of fixed current. This developed product could microscopic operation fewer than 1 [mm]. This development technology is considered by do metallic surface heat treatment, melting, welding, induction heating device and that can apply to domestic animals surgical operation and so on.

  • PDF

표본건물 계측에 의한 공동주택 세대에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석 (Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use based on Measurements of Sample Apartment Units)

  • 진혜선;임한영;이수진;김성임;임재한;송승영
    • 대한건축학회논문집:구조계
    • /
    • 제34권7호
    • /
    • pp.43-52
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and CO2 emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 50 sample apartment units in Seoul. In addition, estimated site EUIs by end use were compared to the U.S. Residential Energy Consumption Survey (RECS) 2009 data. Site EUIs by end use were found to be in the order of heating > electric appliance > domestic hot water > cooking > lighting > cooling > air movement. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the RECS 2009 data, it was found that site EUIs were very similar for heating, domestic hot water and electric appliance, etc., but slightly different for cooling. The number of sample apartment units will continue to increase until 2020 (total number of samples 200) and intensities data by end use will be continuously updated through continuous collection of measurement data.

표본건물 계측에 의한 업무시설에서의 용도별 에너지사용량 및 CO2 배출량 연간 원단위 (2016 - 2017) 분석 (Annual Intensities (2016-2017) Analysis of Energy Use and CO2 Emission by End Use Based on Measurements of Sample Office Building)

  • 임한영;임수현;진혜선;김성임;이수진;임재한;송승영
    • 대한건축학회논문집:구조계
    • /
    • 제34권8호
    • /
    • pp.19-27
    • /
    • 2018
  • In this study, annual site and primary energy use intensities (EUIs) and $CO_2$ emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 19 sample office buildings in Seoul. In addition, the estimated site EUIs by end use were compared to the U.S. Commercial Buildings Energy Consumption Survey (CBECS) 2012 data. Average site EUIs by end use were found to be in the order of electric appliance (typical floors) > heating > cooling > lighting > air movement > domestic hot water > vertical transportation > city water supply. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the CBECS 2012 data, it was found that the site EUIs were similar for heating, cooling, domestic hot water, and electric appliance, etc., but slightly different for lighting and air movement. The number of sample office buildings will continue to increase until 2020 (total number of samples 85) and intensities data by end use will be continuously updated through continuous collection of measurement data.

선풍기의 운전 상황별 발열특성 및 전류신호 검출 (Detection of Current Signal and Thermal Characteristics of Electric Fan Operated in Various Situations)

  • 김두현;이흥수
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.20-27
    • /
    • 2014
  • Cooling equipment is the frequent occurrence of fire despite the absence of the heating element. National fire statistics in 2013 show that a total of 263 fires occurred in the cooling equipment and the number of electric fan has 145 fire cases. This is accounted for 55.1% of the whole. Electric fan is the electrical appliance that the heat is generated on the winding wire and the iron core. If such characteristic is not controled properly, fire would break out at the electric fan. also there is a gap filled with an insulator between connection terminals of the capacitor in the electric fan. But in case that the gap on the capacitor is covered with some conductive material such as dust, there would be a fire as well caused by electrical heating locally. Although many studies related with those have been conducted, electric fan fire is continuously occurred. In this study, thermal characteristics and current signal in various conditions such as the heat generation of windings including iron cores of the motor and the dielectric breakdown of terminals on the capacitor connected to the motor were detected. In order to measure the maximum temperature, "third level" wind velocity button was pushed and the time selection switch to "continuation" was set. Analyzed data would be available for the fire safety of the electric fan.

듀얼 모드 위상 시프트 ZVS PWM 제어 고주파 공진형 인버터를 이용한 IH 온수기 (Induction Heating Water Heater using Dual Mode Phase Shifted ZVS-PWM High Frequency Resonant Inverter)

  • 정상석;유의정;우경일;박한석
    • 전기학회논문지P
    • /
    • 제67권2호
    • /
    • pp.82-89
    • /
    • 2018
  • This paper presents a novel prototype of dual mode control based phase shift ZVS PWM high frequency load resonant inverter with lossless snubber capacitors in addition to a single active auxiliary resonant snubber for electromagnetic induction heating(IH) foam metal based consumer fluid dual packs(DPA) heater. The operating principle in steady state and unique features of this voltage source soft switching high frequency inverter circuit topology are described in this paper. The lossless snubber and auxiliary active resonant snubber assisted constant frequency phase shift ZVS PWM high frequency load resonant inverter employing IGBT power modules actually is capable of achieving zero voltage soft commutation over a widely specified power regulation range from full power to low power. The steady state operating performances of this dual mode phase shift PWM series load resonant high frequency inverter are evaluated and discussed on the basis of simulation and experimental results for induction heated foam metal heater which is designed for compact and high efficient moving fluid heating appliance in the consumer pipeline systems.

A Novel Utility AC Frequency to High Frequency AC Power Converter with Boosted Half-Bridge Single Stage Circuit Arrangement

  • Saha, Bishwajit;Kwon, Soon-Kurl;Koh, Hee-Seog;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2006
  • This paper presents a novel soft-switching PWM utility frequency AC to high frequency AC power conversion circuit Incorporating boost-half-bridge inverter topology, which is more suitable and acceptable for cost effective consumer induction heating applications. The operating principle and the operation modes are presented using the switching mode and the operating voltage and current waveforms. The performances of this high-frequency inverter using the latest IGBTs are illustrated, which includes high frequency power regulation and actual efficiency characteristics based on zero voltage soft switching (ZVS) operation ranges and the power dissipation as compared with those of the previously developed high-frequency inverter. In addition, a dual mode control scheme of this high frequency inverter based on asymmetrical pulse width modulation (PWM) and pulse density modulation (PDM) control scheme is discussed in this paper in order to extend the soft switching operation ranges and to improve the power conversion efficiency at the low power settings. The power converter practical effectiveness is substantially proved based on experimental results from practical design example.

  • PDF