• Title/Summary/Keyword: Electric field emission

검색결과 238건 처리시간 0.023초

(Pb,La)$TiO_3$ 강유전체 세라믹에서 분역반전과 Acoustic Emission의 관계 (The Relationship between Domain Switching and Acoustic Emission in (Pb,La)$TiO_3$ Ferroelectric Ceramacs)

  • 최동구;최시경
    • 한국세라믹학회지
    • /
    • 제33권6호
    • /
    • pp.672-678
    • /
    • 1996
  • The relationship between domain switching and acoustic emission (AE) during poling was investigated using the tetragonal ferroelectric ceramics with composition of (Pb,La)TiO3+0.01MnO2 The amount of AE generation during poling increased with increasing dc electric field and raising temperature. It was confirmed that the change of the amount of AE generation with poling condition resulted from the difference of the amount of 90$^{\circ}$ domain switching and total amount of AE generation for 10 minutes was approximately proportional to the amount of 90$^{\circ}$domain switching. The A generations of two specimens which have different tetragonality rations(c/s rations) 15 at% and 24at% La-doped were also investigated. The sample with c/a ratio of 1.012 where 90$^{\circ}$ domains are dominate had larger amount of AE generation and 90$^{\circ}$ domain switching compared with the sample with c/a ratio of 1.004 where 180$^{\circ}$ domains are dominant.

  • PDF

Reduction of Current Crowding in InGaN-based Blue Light-Emitting Diodes by Modifying Metal Contact Geometry

  • Kim, Garam;Kim, Jang Hyun;Park, Euyhwan;Park, Byung-Gook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권5호
    • /
    • pp.588-593
    • /
    • 2014
  • Current crowding problem can worsen the internal quantum efficiency and the negative-voltage ESD of InGaN-based LEDs. In this paper, by using photon emission microscope and thermal emission microscope measurement, we confirmed that the electric field and the current of the InGaN-based LED sample are crowded in specific regions where the distance between p-type metal contact and n-type metal contact is shorter than other regions. To improve this crowding problem of electric field and current, modified metal contact geometry having uniform distance between the two contacts is proposed and verified by a numerical simulation. It is confirmed that the proposed structure shows better current spreading, resulting in higher internal quantum efficiency and reduced reverse leakage current.

Microdischarge using priming particles for reducing neon emission in AC plasma display panel with Ne-Xe-He gas mixture

  • Kim, Hyun;Jang, Sang-Hun;Tae, Heung-Sik;Chien, Sung-Il;Lee, Dong-Ho
    • 센서학회지
    • /
    • 제15권4호
    • /
    • pp.284-290
    • /
    • 2006
  • This study uses neon, xenon, and helium gas mixture microdischarge to determine the effects of priming particles on the neon emission characteristics in an alternate current plasma display panel (AC PDP). The infrared (823 nm) and neon emission (585 nm) intensities are measured and compared in the blue cells in the case of new discharge with priming particles or conventional discharge without priming particles, respectively. It is found that the priming particles can produce a plasma discharge effectively even under the weak electric field condition, thereby resulting in reducing the neon emission intensity remarkably without sacrificing the IR emission intensity. As a result, it is found that the Ne emission intensity is reduced by about 46.4 % but the blue visible emission intensity is increased by about 15.2 % when compared with the conventional discharge without priming particles.

Thin Oxide 불량에 미치는 Czochralski Si 웨이퍼의 미소결함의 영향 (The Effect of the Microdefects in Czoscralski Si wafer on Thin Oxide Failures)

  • 박진성;이우선;김갑식;문종하;이은구
    • 한국세라믹학회지
    • /
    • 제34권7호
    • /
    • pp.699-702
    • /
    • 1997
  • The cross sectional image of thin oxide failure of MOS device could be observed by Emission Microscope and Focused Ion Beam at the weak point. The oxide failures in low electric field was associated with the presence of a particle or abnormal pattern. The failures occuring at medium field are related to a pit of Si substrate. The pits could be originated from the microdefects of Cz Si wafer.

  • PDF

천리안위성의 발사체와의 전자파 적합성 시험결과 분석 (RF Compatibility Test Results of COMS satellite with Launch Vehicle)

  • 최재동
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.215-217
    • /
    • 2010
  • This paper describes the test results of radiated compatibility with Ariane 5 launcher performed on the COMS Satellite test facility. Firstly, the Radiated Emission test results are analyzed in compliance with the Radiated Susceptibility requirement specification of Ariane 5 launcher. The satellite nominal operation is monitored during injection a radiated electric field corresponding to the launcher emissions levels in critical frequency ranges. And also, E-field are measured through a probe located at external units level in order to assess the EMC safety margin in Radiated mode.

  • PDF

A design of transmission-type multi-target X-ray tube based on electric field modulation

  • Zhao, Lei;Jia, Wenbao;Jin, Limin;Shan, Qing;Cheng, Can;Zhu, Hongkui;Hei, Daqian
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3026-3034
    • /
    • 2021
  • Multi-target X-ray tube is a new type X-ray source, and can be applied in many fields such as sensitive X-ray fluorescence analysis and medical imaging. In this work, we report an electric field modulation multi-target X-ray tube, which contains four targets (Cr, Ni, Au, Mo) coated on a Beryllium (Be) window. A four-valve electric field deflector was developed to deflect the electron beam to bombard the corresponding targets. Particle dynamics analysis software was employed to simulate the particle tracking of electron beam. The results show that the 30 keV electron beam could get a 6.7 mm displacement on the target plane by 105 V/m electric field. The focus areas are about 2 mm × 5 mm and 4 mm × 2.5 mm after deflection in two directions. Thermal behavior calculated by ANSYS shows that the designed target assembly could withstand a 10 W continuous power. The optimum target thicknesses and emission spectra were obtained by Geant4 when the thickness of Be window was 300 mm and the electron beam incident angle was 0.141 rad. The results indicate that this multi-target X-ray tube could provide different X-ray sources effectively.

층류 자유제트유동에 인가된 교류전기장의 영향 (Effect of AC electric fields on Free Jet Flow in a Laminar)

  • 김경택;이원준;차민석;박정;정석호;권오붕;김민국;이상민;윤진한;길상인
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.79-81
    • /
    • 2015
  • The experimental study on gasesous laminar free-jet flow was investigated by applying high voltage alternating current (AC) to the nozzle. The jet flows were affedcted significatly by AC electric fields particularly at high voltages for applied frequencies less than 80 Hz, while those were not responded to further increased frequencies. Under certain AC conditions of applied voltgae and frequency, the laminar gaseous fuel stem was broken down at an axial distance and subsequently separtaed into some parts. The velocity fields in jet flows interactiong with applied electric fields were compared with those without having electric field. Interaction of applying electric fields with laminar free jet flow was discussed in detail, and the possible mechanism was also explained.

  • PDF

Fabrication of Carbon Nanotube Field Emitters

  • Yoon, Hyeun-Joong;Jeong, Dae-Jung;Jun, Do-Han;Yang, Sang-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권1호
    • /
    • pp.121-124
    • /
    • 2008
  • This paper presents the fabrication and field emission of carbon nanotube field emitters for a micro mass spectrometer. The carbon nanotube is an adequate material as a field emitter since it has good characteristics. We have successfully fabricated a diode field emitter and a triode field emitter. Each field emitter has been constructed using several micromachining processes and a thermal CVD process. In the case of the diode field emitter, to increase the electric field, the carbon nanotubes are selectively grown on the patterned nickel catalyst layer. The electron current of the diode field emitter is 73.2 ${\mu}A$ when the anode voltage is 1100V. That of the triode field emitter is 3.4 pA when the anode voltage is 1000V.

침형 상압 마이크로 플라즈마 장치에서 발생하는 전기장이 세포 사멸에 미치는 효과 (The effect of RF electric fields from an atmospheric micro-plasma needle device on the death of cells)

  • 윤현진;손채화;김규천;이해준
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2249-2254
    • /
    • 2008
  • A non-thermal micron size plasma needle is applicable for medical treatment because it includes radicals, charged particles, ultraviolet emission, and strong electric fields. The electric fields around the plasma needle device driven by a radio frequency wave are investigated in order to calculate the power delivered to the cell. A commercial multi-physics code, CFD-ACE, was utilized for the calculation of electric fields for the optimization of the needle structure. The electric field and energy absorption profiles are presented with the variation of the device structure and the distance between the needle and tissues. The living tissues effectively absorb the radio frequency power from the plasma needle device with the covered pyrex structure.

Negative Corona Onset Characteristic of the UHV Conductors Based on the Corona Cage

  • Liu, Yun-Peng;Zhu, Lei;Lv, Fang-Cheng;Xie, Xiongjie
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2089-2097
    • /
    • 2014
  • Negative corona onset characteristics of the stranded conductors based on the ultra-high voltage (UHV) corona cage were studied in the paper. Based on the corona self-sustaining criterion in extreme uneven electric fields and the secondary emission process of the photoelectrons, the corona onset calculation model in the UHV corona cage is established and the corona current tests of the single LGJ900-75, 6 bundle LGJ900-75, 8 bundle LGJ400-35 conductors in dry and rain conditions were done in the UHV corona cage, and the rain rates are 2.4 mm/h, 20 mm/h and 30 mm/h. Corona onset electric field strength is gained by E-I tangent method, and the onset electric field strength in dry condition proves that the calculation model can be used to calculate the corona onset characteristics of the bundle conductors in the UHV corona cage. A further analysis proves that: the negative corona onset voltage of the conductor increases with the bundle number and the diameter of the sub conductor, but decreases with the bundle space in the corona cage. The onset electric field strength is influenced little by bundle space and bundle number, but decreases with the increase of the diameter of the sub-conductor. The surface irregularity coefficient decreases with the rain rate.