• Title/Summary/Keyword: Electric field density

Search Result 582, Processing Time 0.029 seconds

Electric Field Analysis Using Three Dimensional Boundary Integral Equation Method (3차원 경계적분방정식법을 이용한 정전장 해석)

  • Kim, Jae-Hong;Kim, Dong-Hun;Park, Il-Han
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.828-830
    • /
    • 2000
  • This paper describes BIEM(Boundary Integral Equation Method) for computation of three dimensional electric field distribution and numerical method that an equivalent charge density is unknown variable. After computing numerically the surface charge distribution. the distribution of both potential and electric field are obtained. Finally, this numerical method is applied to the concentric sphere and the coaxial cylindrical model and numerical result is compared to the analytic solution.

  • PDF

Analysis of the Rotational Magnetic Field using the FEM and the 2-Dimensional Permeability Tensor (유한 요소법과 이차원 텐서를 이용한 회전자계의 특성 해석)

  • Lee, Chang-Hwan;Kim, Hong-Kyu;Jung, Hyun-Kyo;Hong, Sun-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.169-171
    • /
    • 1996
  • Recently, the finite element analysis(FEM) using two dimensional magnetic permeability tensor was introduced to calculate the magnetic field considering the rotational hysteresis. We obtain the tensor matrix from the measured data using two-dimensional magnetic measuring apparatus. We calculate the induced magnetic flux density and the rotational hysteresis loss under the model with the same condition with the measuring apparatus. Therefore we show that FEM with tensor can be used to calculate the magnetic flux density and the rotational hysteresis loss in the arbitrary rotational magnetic field.

  • PDF

Three Dimensional Electric Field Analysis Of Substation Using Nonuniform Optimal Charge Simulation (비균등 최적 전하배치를 이용한 전력소 3차원 전계해석)

  • Myung, Sung-Ho;Lee, Byeong-Yoon;Min, Suk-Won;Kim, Eung-Sik;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.290-292
    • /
    • 1994
  • This paper presents a methodology for the electric field analysis of substation. For the electric field analysis of substation, the electrodes(substation busbars) must be represented by finite line with nonlinear charge density. In the case of dividing finite line into uniform segments, a large number of variables have to be used to obtain the accuracy within a desired tolerance. To deal with the problem, nonuniform charge arrangement modeling method is suggested. To reduce potential calculation errors, the linear charge density function is considered particularly for the segment charge model ling. If the charge arrangement is improper, the accuracy not improved regardless of increment in the number of segments. This paper proposes an optimal charge arrangement method through potential error analysis. And, the optimal charge arrangement function is formulated by a lot of simulation results.

  • PDF

Optical Properties of Plasmons in a GaAs/AlxGa1-xAs Multiple Quantum Well Under Electric and Magnetic Fields (전기장과 자기장하의 GaAs/AlxGa1-xAs 다중 양자 우물 내 플라즈몬의 광학적 속성)

  • Ahn, Hyung Soo;Lee, Sang Chil;Kim, Suck Whan
    • New Physics: Sae Mulli
    • /
    • v.68 no.11
    • /
    • pp.1183-1191
    • /
    • 2018
  • The plasmon behaviors in a superlattice of $GaAs/Al_xGa_{1-x}As$ multiple quantum wells with a half-parabolic confining potential due to different dielectric interfaces are studied under magnetic and electric fields perpendicular and parallel to the superlattice axis by using a previously published theoretical framework. From the density-density correlation functions by considering the intrasubband and the inter-subband transitions under the random phase approximation, we calculate the dispersion energies of the surface and the bulk states as functions of the composition of the multiple quantum well structure and of the magnetic field strength and the average electric field strength over the quantum well. The Raman intensities for various magnetic field strengths and average electric field strengths over the quantum well are also obtained as a function of the energy of the incoming light for these states.

Electrohydrodynamic Analysis of Dielectric Guide Flow Due to Surface Charge Density Effects in Breakdown Region

  • Lee, Ho-Young;Kang, In Man;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.647-652
    • /
    • 2015
  • A fully coupled finite element analysis (FEA) technique was developed for analyzing the discharge phenomena and dielectric liquid flow while considering surface charge density effects in dielectric flow guidance. In addition, the simulated speed of surface charge propagation was compared and verified with the experimental results shown in the literature. Recently, electrohydrodynamics (EHD) techniques have been widely applied to enhance the cooling performance of electromagnetic systems by utilizing gaseous or liquid media. The main advantage of EHD techniques is the non-contact and low-noise nature of smart control using an electric field. In some cases, flow can be achieved using only a main electric field source. The driving sources in EHD flow are ionization in the breakdown region and ionic dissociation in the sub-breakdown region. Dielectric guidance can be used to enhance the speed of discharge propagation and fluidic flow along the direction of the electric field. To analyze this EHD phenomenon, in this study, the fully coupled FEA was composed of Poisson's equation for an electric field, charge continuity equations in the form of the Nernst-Planck equation for ions, and the Navier-Stokes equation for an incompressible fluidic flow. To develop a generalized numerical technique for various EHD phenomena that considers fluidic flow effects including dielectric flow guidance, we examined the surface charge accumulation on a dielectric surface and ionization, dissociation, and recombination effects.

Spatial and Statistical Properties of Electric Current Density in the Nonlinear Force-Free Model of Active Region 12158

  • Kang, Jihye;Magara, Tetsuya;Inoue, Satoshi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.46.1-46.1
    • /
    • 2016
  • The formation process of a current sheet is important for solar flare from a viewpoint of a space weather prediction. We therefore derive the temporal development of the spatial and statistical distribution of electric current density distributed in a flare-producing active region to describe the formation of a current sheet. We derive time sequence distribution of electric current density by applying a nonlinear force-free approximation reconstruction to Active Region 12158 that produces an X1.6-class flare. The time sequence maps of photospheric vector magnetic field used for reconstruction are captured by a Helioseismic and Magnetic Imager (HMI) onboard Solar Dynamic Observatory (SDO) on 10th September, 2014. The spatial distribution of electric current density in NLFFF model well reproduce observed sigmoidal structure at the preflare phase, although a layer of high current density shrinks at the postflare phase. A double power-law profile of electric current density is found in statistical analysis. This may be expected to use an indicator of the occurrence of a solar flare.

  • PDF

The Electrical Conduction Properties of Polyethylene Thin Film for Power Cable with Manufacturing Methods (제작방법에 따른 전력케이블용 폴리에틸렌 박막의 전기전도특성)

  • 조경순;이용우;이수원;홍진웅
    • Electrical & Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.453-460
    • /
    • 1997
  • In order to investigate the electrical conduction properties of polyethylene thin film for power cable with manufacturing methods, the thickness of specimen was the 30, 100[${\mu}{\textrm}{m}$] of LDPE and 200[${\mu}{\textrm}{m}$] of XLPE were manufactured. The experimental condition for conduction properties was measured until the breakdown occurs at temperature ranges from 30 to 110[$^{\circ}C$] and the electric field from 1$\times$10$^3$to 5$\times$10$^{6}$ [V/cm]. As for increase of temperature, the current density of LDPE was increased with constant ratio in low field, but changes with exponential function in high electric field. The tunnel current of pre-breakdown region is shifted toward low field as much as thermal excitation energy. At low electric field, the XLPE showed dominant electrical conduction properties by thermal excitation, and transformation of the electron was resisted by the crystal at high electric field.

  • PDF

Prediction and Analysis of Electrical Environmental Characteristics under ±500kV HVDC Double Bipole Transmission Line (±500kV HVDC 2회선 송전선로의 전기환경특성 예측 및 평가)

  • Woo, Jeong Min;Ju, Mun-No;Shin, Koo Yong;Kwon, Gu Min;Choi, Woo Jung;Lee, Jae Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.4
    • /
    • pp.554-560
    • /
    • 2018
  • Since Korea has a small land area, it is expected to construct the conductor return type with neutral wire in the case of ${\pm}500kV$ HVDC double bipole transmission line. Therefore, in order to apply ${\pm}500kV$ HVDC double bipole transmission line with neutral wire in Korea, it is necessary to develop technology for insulation and environmental designs. In this study, radio interference, audible noise, electric field and ion current density according to the polarity arrangement were compared and assessed in the ${\pm}500kV$ HVDC double bipole transmission line with the conductor return method. And the optimum configuration of HVDC double bipole transmission line was determined from the viewpoint of electrical environment.

Time-Varying Seismogenic Coulomb Electric Fields as a Probable Source for Pre-Earthquake Variation in the Ionospheric F2-Layer

  • Kim, Vitaly P.;Hegai, Valery V.;Liu, Jann Yenq;Ryu, Kwangsun;Chung, Jong-Kyun
    • Journal of Astronomy and Space Sciences
    • /
    • v.34 no.4
    • /
    • pp.251-256
    • /
    • 2017
  • The electric coupling between the lithosphere and the ionosphere is examined. The electric field is considered as a timevarying irregular vertical Coulomb field presumably produced on the Earth's surface before an earthquake within its epicentral zone by some micro-processes in the lithosphere. It is shown that the Fourier component of this electric field with a frequency of 500 Hz and a horizontal scale-size of 100 km produces in the nighttime ionosphere of high and middle latitudes a transverse electric field with a magnitude of ~20 mV/m if the peak value of the amplitude of this Fourier component is just 30 V/m. The time-varying vertical Coulomb field with a frequency of 500 Hz penetrates from the ground into the ionosphere by a factor of ${\sim}7{\times}10^5$ more efficient than a time independent vertical electrostatic field of the same scale size. The transverse electric field with amplitude of 20 mV/m will cause perturbations in the nighttime F region electron density through heating the F region plasma resulting in a reduction of the downward plasma flux from the protonosphere and an excitation of acoustic gravity waves.

A Study on The Distribution of Surface Charge Density on Polymer Insulators (고분자애자의 표면전하밀도 분포에 관한 연구)

  • Yang, J.J.;Hwang, B.M.;Kim, K.S.;Lee, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.354-356
    • /
    • 1997
  • In this paper, we study the distribution of surface charge density on polymer insulators. The electric field of polymer insulators is calculated by axisymetric 3-D FEM with dc source. And the surface charge density is calculated by electric scalar potential and boundary condition for electrostatic fields. Simulation model is the inclined type polymer insulator with a shed.

  • PDF