• 제목/요약/키워드: Electric distribution systems

검색결과 433건 처리시간 0.031초

전력용 변압기의 절연유가 전계에 미치는 수치해석적 모델 (A Numerical Model of the Electric Field Distribution in Power Transformers)

  • 신판석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.3-6
    • /
    • 1990
  • The impact of the convected charges, which is caused by the electrification phenomina, in the oil-paper insulation systems of power transformers has been numerically investigated using FEM. The potential distribution of the oil-paper insulation system is assumed to be governed by three equations instead of the classical Laplace equation. When the charge density of oil and the conduction current are kept high, the field distortion or the interrace in a power transformer is considerably distorted due to the convected charges.

  • PDF

Characteristic Impedances in Low-Voltage Distribution Systems for Power Line Communication

  • Kim, Young-Sung;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.29-34
    • /
    • 2007
  • The input and output impedances in a low voltage distribution system is one of the most important matters for power line communication because from the viewpoint of communication, the attenuation characteristic of the high frequency signals is greatly caused by impedance mismatch during sending and receiving. The frequency range is from 1MHz to 30MHz. Therefore, this paper investigates the input and output impedances in order to understand the characteristic of high frequency signals in the low voltage distribution system between a pole transformer and an end user. For power line communication, the model of Korea's low voltage distribution system is proposed in a residential area and then the low voltage distribution system is set up in a laboratory. In the low voltage distribution system, S parameters are measured by using a network analyzer. Finally, input and output impedances are calculated using S parameters.

An Economic Analysis of Potential Cost Savings from the Use of Low Voltage DC (LVDC) Distribution Network

  • Hur, Don;Baldick, Ross
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.812-819
    • /
    • 2014
  • The proposed technical work attempts to compare the two key technologies of power distribution, i.e. direct current (DC) and alternating current (AC) in a fiscal manner. The DC versus AC debate has been around since the earliest days of electric power. Here, at least four types of a low voltage DC (LVDC) distribution are examined as an alternative to the existing medium voltage AC (MVAC) distribution with an economic assessment technique for a project investment. Besides, the sensitivity analysis will be incorporated in the overall economic analysis model to cover uncertainties of the input data. A detailed feasibility study indicates that many of the common benefits claimed for an LVDC distribution will continue to grow more profoundly as it is foreseen to arise with the increased integration of renewable energy sources and the proliferation of energy storage associated with the enhanced utilization of uninterruptible power supply (UPS) systems.

전기자동차 화재 대응을 위한 제도적 개선 방안 연구: 서울시 사례를 중심으로 (A Study of Institutional Improvements for Responding to Electric Vehicle Fires: Focusing on the Case of Seoul)

  • 박남권;함승희
    • 한국재난정보학회 논문집
    • /
    • 제20권1호
    • /
    • pp.32-39
    • /
    • 2024
  • 연구목적과 방법: 전기차 화재에 대한 대응력을 향상시키기 위해 제도적 개선방안을 제시하고자 한다. 이를 위해 서울시를 중심으로 전기차 보급 및 화재 발생 현황, 관련 법 제도를 살펴보았다. 연구결과: 전기차 관련 상위법령 및 조례는 보급정책만 중심적으로 규정되어 있어 전기차 화재에 대해 실질적인 화재 대응 방안이 없는 상황이다. 각 자치단체별로 동일한 규정을 적용하기 위해서는 상위법령에서 소방 및 안전 시설에 대한 기준 정립과 제도 확립이 필요하다. 결론: 전기차 화재 특성을 고려한 소방 및 안전시설 설치 기준을 정하고 관련 제도의 개선을 통해 전기자동차 화재에 대한 시민들의 우려를 잠식시키는 것이 궁극적으로 전기차 보급률을 향상시키는 효과로 이어질 것이다.

장주기 대용량 전력저장장치의 부하이전에 대한 실계통 적용 경제성 평가 연구 (An Economic Assessment of Large-scale Battery Energy Storage Systems in the Energy-Shift Application to Korea Power System)

  • 박종배;박용기;노재형;장병훈;윤용범
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.384-392
    • /
    • 2015
  • This paper presents an economic assessment of large-scale Li-ion battery energy storage systems applied to Korean power system. There are many applications of the battery energy storage systems (BESSs) and they can provide various benefits to power systems. We consider BESSs to the energy time-shift application to Korean power system and evaluate the benefits from the application of BESS in the social perspective. The mixed integer programming (MIP) algorithm is used to resolve the optimal operation schedule of the BESS. The social benefits can include the savings of the fuel cost from generating units, deferral effects of the generation capacity, delay of transmission and distribution infra construction, and incremental CO2 emission cost impacts, etc. The economic evaluation of the BESS is separately applied into Korean power systems of the Main-land and Jeju island to reflect the differences of the load and generation patterns.

Load Flow Calculation and Short Circuit Faults Transients in Dispersed Generation Systems

  • Hosseini, Seyed Hossein;Shahnia, Farhad;Tizghadam, Saeed
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.800-804
    • /
    • 2005
  • Load flow and short circuit fault transients of a power distribution system with wind turbines as dispersed generation units is presented. Usage of renewable energies such as wind is already a small part of total installed power system in medium and low voltage networks. In this paper, a radial power distribution system with wind turbines is simulated using DIgSILENT PowerFactory software for their influence on load flow and short circuit fault transients. Short fault occurring in dispersed generation systems causes some problems for the system and costumers such as fault level increase or the problems of sudden fluctuations in the current, voltage, power and torque of the double fed induction machine utilized in the wind turbines which have been studied and investigated.

  • PDF

회전기의 기여에 의한 시변성의 순간전압강하 예측에 관한 연구 (Investigation of the Estimation of Time-Varying Voltage Sags Considering the Short Circuit Contributions of Rotating Machines)

  • 윤상윤
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권6호
    • /
    • pp.315-322
    • /
    • 2005
  • In this article, 1 would like to explore the estimation method of time-varying voltage sags in large industrial systems considering the short circuit contributions of rotating machines. For the power distribution system of KEPCO(Korea Electric Power Corporation), the magnitude of initial symmetrical short circuit current is generally not changed. However, in industrial systems which contain a number of rotating machines, the magnitude of voltage sag is generally changed from the initial to the clearing time of a fault due to the decreasing contribution of rotating machines for a fault current. The time-varying characteristics of voltage sags can be calculated using a short circuit analysis that is considered the time-varying fault currents. For this, the prediction formulations of time-varying voltage sags are proposed using a foreign standard. The proposed method contains the consideration of generator and motor effects. For the test of proposed formulations, a simple system of industrial consumer is used for the comparison conventional and proposed estimation method of voltage sag characteristics.

배전계통 고장위치 확인을 위한 고장점 표정기법 (The Fault Distance Computation Method for Fault Location Identification of Distribution System)

  • 고윤석
    • 한국전자통신학회논문지
    • /
    • 제3권4호
    • /
    • pp.276-281
    • /
    • 2008
  • 배전계통은 여러 가지 이유로 잦은 고장을 경험하기 때문에 고장위치 추정은 전력공급 신뢰도 측면에서 매우 중요하다. 그렇지만 배전계통은 주 선로에서 분기되는 3상 및 단상 분기선을 가지는 수지상 구조로 설계되며 각 구간 상에 수개의 로드 탭을 가지기 때문에 고장점 표정이 어렵다. 따라서 본 연구에서는 기존의 전력계통 고장점 표정기법에 대해서 조사, 분석하여 배전자동화시스템의 중앙제어장치에서 효과적으로 실행할 수 있는 고장거리 계산 기법을 결정한다. 그리고 EMTP 모의 결과를 통해 결정된 방법의 유효성을 검증한다.

  • PDF

전압플리커 저감과 역률 보상 기능을 갖는 배전용 STATCOM의 실계통연계 운전결과 분석 (Analysis of the Distribution STATCOM for Improving the power factor and Mitigation of Voltage Flicker in Real System)

  • 오관일;전영수;박상태;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.245-248
    • /
    • 2000
  • This paper presents the test and operation results of the domestic demonstration of the reactive power compensation device called STATCOM (STATic COMpensator). The object of the paper is to describe the reliability of the unit based on the extensive operation databases. By controlling reactive power, the technology offers utilities the opportunity for increased efficiency and their capabilities will permit transmission planners make the best use of their existing transmission resources STATCOM is a custom power device in a way and can be used in a similar way for the dynamic compensation of power transmission systems, mitigation of voltage flicker and improving the power factor. It is shown that the STATCOM has clear advantages in areas such as: mitigation of voltage flicker and improving power factor.

  • PDF

다른계통으로 연계된 두개의 변전소의 배전계통 특성 연구 (Study on Distribution System Characteristic Of Two Substations Coupling Different Power Systems)

  • 권오형;문봉수;김태옥;강유원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.670-672
    • /
    • 2005
  • 발전원이 다른 계동으로 연계된 춘천, 남춘천변전소의 태전선로간 Loop 시행시 일부배전선로가 Trip되는 현상에 대하여 PSSE 검토 TOOL을 활용하여 계통을 모의하고 변압기 병렬운전조건에 대한 물리적 의미와 검토대상 배전선로 계통특성, 주변 발전원의 발전력과의 상관관계를 기술검토를 통하여 계통특성을 분석함으로써 Loop시행이 가능한 계통여건을 파악, 선로 운영의 최적방안을 제시하고자 한다.

  • PDF