• Title/Summary/Keyword: Electric device

검색결과 1,832건 처리시간 0.036초

전기자동차 충전구 위치에 따른 전자파 방사특성에 관한 연구 (A Study on Electromagnetic Interference of Electric Vehicles with Variations of Charging Device Inlet Location)

  • 권순민;우현구
    • 한국자동차공학회논문집
    • /
    • 제24권6호
    • /
    • pp.694-701
    • /
    • 2016
  • According to revolutionary developments in automobile technologies, eco-friendly advanced vehicles (hybrid vehicle, hydrogen fuel-cell vehicle, electric vehicle, etc.) are rapidly increasing. The electromagnetic compatibility is getting more important for development of a vehicle because those advanced vehicles are driven by electric energy and equipped with more electric systems. In general, electromagnetic compatibility tests consist of an electromagnetic interference(EMI) test and an electromagnetic susceptibility(EMS) test. EMI test of the electric vehicles are needed not only in driving mode but also in charging mode because they must be recharged by much electric energy for driving. Depending on vehicle manufacturers, the charging device type and the location of charging device inlet in electric vehicles are various. In this paper, in order to investigate EMI of electric vehicles in charging mode in consideration of the direction of measuring antenna and the location of charging device inlet, a series of electromagnetic emission tests are conducted using three electric vehicles (neighborhood electric vehicle, electric vehicle and electric vehicle-bus). The test results show that electromagnetic emission measurements in charging mode are dependent on the direction of measuring antenna and the location of charging device inlet.

고정밀 전기식 힘측정기의 불확도평가 절차 및 응용 (Procedure for Uncertainty Evaluation of a Precision Electric Force Measuring Device and Its Application)

  • 김갑순;강대임
    • 한국정밀공학회지
    • /
    • 제16권12호
    • /
    • pp.161-167
    • /
    • 1999
  • This paper describes the calibration method and the calculation equations of expanded uncertainty for a precision electric force measuring device. The calibration of the electric force measuring device is performed three times (0 ${\circ}$(first time), $120{\circ}$(second time), $240{\circ}$(third time)) at each calibration point. It is usually selected ten points from zero load to rated load of the electric force measuring device. The expanded uncertainty is calculated by combining A type standard uncertainty and B type standard uncertainty. The calibration method and the calculation equations of expanded uncertainty can be widely used in the calibration of the precision electric force measuring device.

  • PDF

Sewing-enabled electric button for smart fabric

  • Lee, Kang-Ho;Lee, Dongkyu;Lee, Yong-Goo;Kwon, Ohwon
    • 센서학회지
    • /
    • 제30권2호
    • /
    • pp.67-70
    • /
    • 2021
  • A new button-shaped electrical device was developed for a smart fabric. This electric button can be sewn anywhere on the garment, similar to a traditional button fastener. t not only performs a decorative function but also makes the fabric suitable for use in Internet of Things (IoT) applications. It has metallic through-holes such that it can be fastened onto a fabric by conductive sewing threads. When threaded through metallic holes, the button can communicate with the external device by transmitting and receiving data. In addition, it adds specific functions by stacking a detachable application layer on the base layer. It is robust to frequent washing, and thus has excellent repeatability for use as an IoT device. The feasibility of the electric button was successfully demonstrated by its ability to identify the physical activities of walking and running, monitoring ambient temperature, and turning on LED lights.

이동형 전기기기의 감전재해 특성 및 그 대책 (The Characteristics of Electric Shock Accidents and Their Countermeasures for Portable Electrical Tools)

  • 최상원
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.21-26
    • /
    • 2017
  • According to the data of Korea Occupational Safety and Health Agency, electric shock accidents during recent 11 years exceeded more than 60% in architecture/other and construction work, the countermeasures for safety are required in the harsh environment of a construction site where moving electric machines and equipments are widely used. The establishment of countermeasure for insulation degradation and defect is required, in consideration of increasing trend for accidents caused by defective insulation among low voltage electrical installation each year. The aim of this study is to propose the policy about portable electrical tool standards and/or worker's safety standards for preventing electric shock accidents on safety workings, and is to develop the technology and the safety device to prevent electric shock for accident prevention reduction through experiments. It obtained the followings through this study; statistical data analysis of late about 10 years of electric shock-related industrial accidents analysis and portable electric tools; safety device development of 'device for testing continuous grounding and power shut-down' to prevent electric shock from portable electric tools. Furthermore, developed results and proposal in this study will help to prevent the electric shock accidents from portable electric tools and will be expected the utilization of policy formulation, educational data and field supplement of the safety device, and etc.

전기히터의 설계 변수에 따른 순간온수기 열유동 특성 해석 (Analysis of heat and fluid flows in an instant water heater according to design parameters of an electric heat device)

  • 쑨휘;김준현;성재용
    • 한국가시화정보학회지
    • /
    • 제21권3호
    • /
    • pp.23-32
    • /
    • 2023
  • This study aims to explore the heat transfer and flow phenomena inside an instant water heater and the influence of the design parameters of the water heater on the heating performance was investigated by 3-D numerical simulations considering heat convection. The design parameters are the heating ceramic dimension, the power of the heating device, and the water flow rate. The results show that a reasonable space for the heating device is required to optimize the heating performance. It is desirable to design higher heating device as possible for a given electric power. There exists a critical water flow rate that best meets the heating performance. The change in electric power has no impact on the flow phenomena and heating performance.

배전자동화 적용선로 보호기기 자동정정 프로그램 개발 (The Development Plan of the Protection Device Auto-coordination Program in the Distribution Automation System)

  • 강문호;하복남;임성일;조남훈;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.129-131
    • /
    • 2001
  • In order to improve the reliability of power service and the effective management of distribution power system. DAS (Distribution Automation system) is widely used in KEPCO(Korea Electric Power Corporation) branch offices. Based on the present protective device coordination program which used in KEPCO. this study presents the new concept about both protective device coordination program maximizing the characteristics of DAS and development plan of protective device auto-coordination program with the merits of DAS.

  • PDF

침형 상압 마이크로 플라즈마 장치에서 발생하는 전기장이 세포 사멸에 미치는 효과 (The effect of RF electric fields from an atmospheric micro-plasma needle device on the death of cells)

  • 윤현진;손채화;김규천;이해준
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2249-2254
    • /
    • 2008
  • A non-thermal micron size plasma needle is applicable for medical treatment because it includes radicals, charged particles, ultraviolet emission, and strong electric fields. The electric fields around the plasma needle device driven by a radio frequency wave are investigated in order to calculate the power delivered to the cell. A commercial multi-physics code, CFD-ACE, was utilized for the calculation of electric fields for the optimization of the needle structure. The electric field and energy absorption profiles are presented with the variation of the device structure and the distance between the needle and tissues. The living tissues effectively absorb the radio frequency power from the plasma needle device with the covered pyrex structure.

규소강판 코어소재의 가공 방법에 따른 철손 특성 (Korean Institute of Electrical and Electronic Materials)

  • 김인성;정순종;민복기;김형욱;송재성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.343-344
    • /
    • 2006
  • 방향성 규소강판을 tape-wound core 형태로 제작하여 가공방법에 따른 자기적 특성을 조사 하였다. 그 결과 곡률반경이 40mm인 시료에서 보자력(Hc)과 포화자속밀도(Bs)는 우수한 값을 나타내었고, 보자력은 0.02Oe, 포화자속밀도는 1.85T 이었다. 현재 국내에서 생산되고 있는 방향성 규소강판의 자속밀도값 보다 우수한 값을 나타내었다. 본 연구로부터 방향성 규소강판을 이용하여 권자심을 제작할 때 도입되는 탄성변형에 대한 대책의 중요성과 코어 소재의 가공방법이 자기적 특성에 미치는 영향을 통해 고효율 방향성 규소강판 개발의 가능성을 확인하였다.

  • PDF

무방향성 규소강판에서 열화특성이 자기적 성질에 미치는 영향 (Aging Characteristic on the Magnetic Properties of Non-oriented Silicon Steel)

  • 김형욱;김인성;정순종;민복기;송재성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.242-242
    • /
    • 2007
  • 무방향성 규소강판을 lamination core 형태로 제작하여 자기적 특성을 조사 하였다. 그 결과 1차, 2차 권선수가 400turns 시료에서 보자력(Hc)과 포화자속밀도(Bs)는 최대값을 나타내었고, 보자력은 0.05Oe, 포화자속밀도는 1.8T 이었다. 현재 국내에서 생산되고 있는 무방향성 규소강판의 자속밀도값 보다 더 우수한 강을 나타내었으며, 열화특성이 자기적 특성에 미치는 영향을 통해 고효율 무방항성 규소강판 개발의 가능성을 확인하였다.

  • PDF

방향성 규소강판에서 열화특성이 자기적 성질에 미치는 영향 (Korean Institute of Electrical and Electronic Materials)

  • 김형욱;김인성;정순종;민목기;송재성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.245-246
    • /
    • 2006
  • 방향성 규소강판을 tape-wound core 형태로 제작하여 $N_2$ gas 분위기에서 $760^{\circ}C$ 4 시간동안 열처리후 자기적 특성을 조사 하였다. 그 결과 1차, 2차 권선수가 85 turns 시료에서 보자력(Hc)과 포화자속밀도(Bs)는 최대값을 나타내었고, 보자력은 0.019Oe, 포화자속밀도는 1.92T 이었다. 현재 국내에서 생산되고 있는 방향성 규소강판의 자속밀도값 보다 더 우수한 값을 나타내었으며, 열화특성이 자기적 특성에 미치는 영향을 통해 고효율 방향성 규소강판 개발의 가능성을 확인하였다.

  • PDF