• 제목/요약/키워드: Electric conductor

검색결과 351건 처리시간 0.028초

전력케이블용 반도전층의 유전/절연특성과 온도 의존성 (A Temperature dependancy and dielectric/insulation properties for power cables)

  • 이종찬;허인성;김광수;박대희;이재관;김동찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1463-1466
    • /
    • 2002
  • In this paper, the thermal analysis and dielectric/insulation properties were investigated with considering the temperature depenence Using the sheet of semi-conductor/XLPE came from 22 kV power cables, the dielectric/insulation properties and temperature dependence were measured under 1kHz. According to the results we can verify that only semi-conductor sheet changed linearly, and with the unstable results. the dielectric/insulation properties of the semi-conductor/XLPE sheet show the highest value in the range of 40 $^{\circ}C$ and 50 $^{\circ}C$ and are rely on XLPE rather than semi-conductor in terms of the temperature.

  • PDF

STACIR/AW 410SQmm 가공송전선의 경년열화와 이도거동(III) (Sag Behavior of STACIR/AW 410SQmm Overhead Conductor in accordance with the Aging)

  • 김상수;김병걸;신구용;이동일;민병욱
    • 한국전기전자재료학회논문지
    • /
    • 제19권3호
    • /
    • pp.280-286
    • /
    • 2006
  • As a way to expand electric capacity in conductor with electric power demand, STACIR/AW (Super Thermal-resistant Aluminum-alloy Conductors Aluminum-clad Invar-Reinforced) conductor which has high electric current and heat resistance characteristics have been developed. STACIR/AW power line is mechanical composite wire composed of steel cores for dip control and aluminum conductors for sending electric current. Recently, to ensure stable operation and prediction of wire life span of STACIR/AW conductor, a heat property of STACIR/AW conductor have been investigated. In the present work, a change of essential property with long term-heat exposure of STACIR/AW conductor and its structure material, INVAR wire and Al conductor, have been investigated. INVAR/AW is approximately $3.2\;{\mu}m/m^{\circ}C$. thermal expansion coefficient of INVAR/AW wire increases with time of heat exposure. the thermal expansion coefficient of INVAR/AW is markedly influenced by heat and mechanical treatment. creep rate(0.242) of STACIR/AW $410\;mm^2$ conductor at room temperature is much higher than that(0.022) at $210\;^{\circ}C$ STACIR/AW $410\;mm^2$ conductor has minimum creep rate at operating temperature. To lower creep rate with increase temperature is more unique characteristics in STACIR/AW. It is expected that STACIR/AW turned its tension to INVAR/AW at the transition temperature. at room temperature, the tension apportionment of INVAR/AW in STACIR/AW is about $50\;\%$. but whole tension of STACIR/AW is placed on the INVAR/AW alone of core metal above transition temperature.

A Novel Non-contact Measurement Method for the Detection of Current Flowing Through Concealed Conductors

  • Yang, Fan;Liu, Kai;Zhu, Liwei;Hu, Jiayuan;Wang, Xiaoyu;Shen, Xiaoming;Luo, Hanwu;Ammad, Jadoon
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.43-48
    • /
    • 2017
  • In order to detect the current flowing through concealed conductor, this paper proposes a new method based on derivative method. Firstly, this paper analyzes the main peak characteristic of the derivative function of magnetic field generated by a current-carrying conductor, and a relationship between the current flowing through the conductor and the main peak of the derivative function is obtained and applied to calculate the current. Then, the method is applied to detect the conductor current flowing through grounding grids of substations. Finally, the numerical experimental and field experiment verified the feasibility and accuracy of the method, and the computing results show that the method can effectively measure the conductor current of grounding grids with low error, and the error is within 5 %.

유한요소법을 이용한 쌍극자 공간전하 방전분산형 피뢰침 정전유도구체의 국부전계 해석 (Local Electric Field Analysis for Evaluation of Charge Transfer System Using Sequential Sub-window Techniq)

  • 정용기;곽희로;이준호;박일한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1650-1652
    • /
    • 2003
  • In this study, in order to increase electric field intensify near a lightning rod a floating conductor is adopted. If a floating conductor is located near the lightning rod, the positive and negative charges are equally induced on the lightning rod and the floating conductor, and the local electric field intensity near them increases. This increase of electric field intensity can ignite easily the ionization process of the surrounding air and the corona phenomenon begins there. It occurs before the usual lightning process begins on the top of the conventional rod. The charges of the ground or some buildings are omitted during the corona process through the floating conductor. Therefore, the probability of the main lightning on the conventional rod can be reduced.

  • PDF

220kV XLPE CABLE 접속함용 Al-Cu 이종접속슬리브 개발 (Development of Friction Welded Al to Cn Bimetallic Sleeve for 220kV XLPE Cable Termination & Joint)

  • 김현주;박정기;박성민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.93-93
    • /
    • 2010
  • We developed friction welded bimetallic sleeve for 220kV aluminum conductor XLPE cable. Not only friction welded bimetallic sleeve for Termination(EB-A, EB-G) but also friction welded sleeve for Joint of Al to Cu conductor was developed regardless of this project. Generally, friction welded sleeve used to connect Al conductor cable to Cu conductor cable and used for improvement of mechanical property of terminal by offer the copper side of friction welded bimetallic sleeve at the Termination. Connection method for Al-Cu conductor has mainly used friction welding at the solid state, because it is difficult to connect by using conventional welding method. this investigation introduces development of friction welded bimetallic sleeve by friction welding and test result of 220kV Al conductor XLPE cable and accessories using friction welded sleeve.

  • PDF

송배전 접속 금구류의 도전 열특성에 관한 연구 (Heat Characteristics of Electric Fittings for Power Transmission Line)

  • 이창식;진양덕
    • 대한기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.697-702
    • /
    • 1989
  • 본 연구에서는 도체의 접속 금구류의 도전 열특성을 규명하기 위한 연구의 일환으로 접속 금구류 중 접속 슬리브커넥터의 적절한 허용 전류, 통전시에 발생하는 승온 특성 및 전기 저항 특성 등을 실험적으로 구하고 접속 금구류의 설계에 필요한 도전 열특성을 실험적으로 규명하는 것을 목적으로 한다.

외부 자계 인가에 따른 고온초전도 케이블 도체의 ?치 특성 (Influence of external magnetic field on HTS cable conductor)

  • Seong Woo Yim;Si Dole Hwang;Je Myoung Oh;Byung Sung Han
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.284-287
    • /
    • 2003
  • Quench characteristics of HTS cable conductor due to external magnetic field were investigated. Firstly, the influence of critical characteristics of HTS tape on locally applied magnetic field was examined. Secondly, critical current of HTS tapes, which are wound on surface of former, were measured respectively, before the experiment for quench characteristics, Finally, 50mT and 100mT were applied to HTS cable conductor and quench characteristics were investigated through V-I curves. As the results, same as the result of HTS tape, HTS cable conductor showed strong dependence on external magnetic field with direction and magnitude.

  • PDF

지표면 위에 한쪽 면이 도체로 된 손실 유전체 슬랩 속의 다이폴 전원에 의한 동일면상의 전계 (An electric field induced on the same plane by a point dipole soruce within a conductor-backed lossy dielectric slab above the earth)

  • 박동국;라정웅
    • 전자공학회논문지A
    • /
    • 제33A권12호
    • /
    • pp.9-15
    • /
    • 1996
  • An electric field induced by a point dipole soruce within a conductor-backed lossy dielectric slab above the earth is calculated by anumerical method. the calcualtion is peformed on the plane which is parallel to the conductor plane and containing the point dipole soruce. Computed S$_{21}$ values of two parallel planar dipole antennas and two collinear planar dipole antennas are compared against each other, as well as the electic field magnitudes in those arrangements.

  • PDF

동복알루미늄의 내염특성 연구 (Study on Salt-Proof Characteristics of Copper Clad Aluminum)

  • 김진사;배덕권
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1764-1768
    • /
    • 2009
  • As the demand of electric power is increasing rapidly, the need of the compact and light electric power device is also increased. Copper clad aluminum (CCA) is newly proposed electrical conductor, because of its light-weight and low-cost characteristics, to replace the existing conductor made of copper. This paper presents the salt-proof characteristics of the copper clad aluminum (CCA) to certificate long time safe operation of the newly proposed electrical conductor. The two types of the CCA conductor were tested in the neutral salt spray tester. The experimental results of two types of the CCA with salt spray were presented in this paper. The results comprise resistance measured data, micro picture of the selected surface, and component measured data according to the elapsed time. The period of the experiment was 1,000 hours. There was no evidence to show the corrosion of CCA during the whole period of the experiments.