• Title/Summary/Keyword: Electric characteristic

Search Result 1,275, Processing Time 0.027 seconds

A study on the characteristic test of the grounding electrodes used in distribution lines (배전용 접지전극의 전극별.공중별 특성시험에 관한 연구)

  • Park, Sang-Man;Park, Jae-Duck;Kang, Moon-Ho;Choi, Jong-Kee;Park, Young-Keun;Shim, Keun-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2005.05b
    • /
    • pp.54-56
    • /
    • 2005
  • On the overhead distribution lines, we generally use a copper rod as a grounding electrode. It is a economical metallic structure. Recently, many new electrodes have been developed and used in the distribution system of KEPCO. Before using new grounding electrode. we need to measure the performance of each electrode for comparative analysis. This report describes the characteristic test of the grounding electrodes used in KEPCO.

  • PDF

Response characteristic of over current relay using optical sensor (광센서를 이용한 과전류 보호계전의 응답특성 연구)

  • 박병석;안성준;조홍근
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1364-1366
    • /
    • 1997
  • To operate electric power systems economically and stably, and to supply the electric power of good quality, it is necessary that the measured information (current, voltage, and so on) be detected and transmutted with high reliability and high effieincy. For the reason, the optical magnetic field sensor is possible to rapidly detect to over current and recover when electric power line have fault. In addition, the optical sensor have no electro magnetic distortion and no electric insulation. In this study, we designed OCR(Over Current Relay) using optical sensor. The designed OCR using optical sensor was measured characteristic and compared contentional OCR. This system have highest optical advantages and reliability.

  • PDF

Transient Response of an Electrorheological Fluid in Shear Flow (전단 유동 하에서 전기유변유체의 과도응답 특성)

  • Choi, Byung-Ha;Nam, Yun-Joo;Park, Myeong-Kwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.6
    • /
    • pp.411-417
    • /
    • 2009
  • The transient shear stress response of an electrorheological fluid is investigated experimentally. The characteristic time constants of an electrorheological fluid sheared between two concentric cylinders were obtained under various electric field strengths and shear rates. Also, two experimental modes are adopted to investigate the effect of the shear flow on the dynamic behavior of the fluid; one is that the electric field is induced before shearing, and the other is the electric field is induced after shearing. From the difference in the response time between two modes, the cluster formation time were obtained. The response times were decreased with the increase of the shear rate, irrelatively of the electric field strength. The cluster formation time were monotonically increased with increase of shear rate, and thereafter, were converged with a certain value.

Power Characteristic Analysis of Assumed Short Circuit Instance of Electric Ship Propulsion System (선박용 전기추진시스템의 단락상정사례의 전력특성 분석)

  • Jeon, Won;Wang, Yong-Peel;Jeong, Jong-Hwa;Lyu, Sung-Kak;Jung, Sang-Yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.323-329
    • /
    • 2008
  • This paper deals with modeling and characteristic analysis of a large-powered electric ship propulsion system. Particularly, system modeling in accordance with the required shipping performance, building-up the equivalent circuit and the power analysis based on load flow have been performed. In addition, abnormal operating condition of short-circuit network is considered for investigating the safety of system components under the over-load condition. Furthermore, protective device like circuit breaker has been specified in order to make the entire system operate normally in case of short-circuit emergency.

Dynamic Characteristic of a 2-phase Hybrid Stepping Motor (2상 하이브리드 스테핑 모터의 동특성)

  • Ahn, Ho-Jin;Kang, Gyu-Hong;Hong, Jung-Pyo;Kim, Gyu-Tak;Lee, Jong-Bae;Sung, Ha-Gyeong;Lim, Tae-Bin
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.837-839
    • /
    • 2001
  • This paper presents dynamic characteristic of a 2 phase hybrid stepping motor which includes pull-out torque with constant voltage drive and one step response. In order to analyze this characteristics, vector diagram of a synchronous motor and torque-voltage equation are used. Analytic results are good agreement with experimental results.

  • PDF

Comparisons of Linear Characteristic for Shape of Stator Teeth of Hall Effect Torque Sensor

  • Lee, Boram;Kim, Young Sun;Park, Il Han
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.285-290
    • /
    • 2012
  • Electric Power Steering (EPS) system is superior to conventional Hydraulic Power Steering (HPS) system in aspect of fuel economy and environmental concerns. The EPS system consists of torque sensor, electric motor, ECU (Electric Control Unit), gears and etc. Among the elements, the torque sensor is one of the core technologies of which output signal is used for main input of EPS controller. Usually, the torque sensor has used torsion bar to transform torsion angle into torque and needs linear characteristic in terms of flux variation with respect to rotation angle of permanent magnet. The torsion angle of both ends of a torsion bar is measured by a contact variable resistor. In this paper, the sensor is accurately analyzed using 3D finite element method and its characteristics with respect to four different shapes of the stator teeth are compared. The four shapes are rectangular, triangular, trapezoidal and circular type.

Electric Field Simulation and Characteristics of Water Treatment Apparatus using Dielectrics (유전체를 이용한 수처리장치의 전계시뮬레이션 및 수처리 특성)

  • Hwang, In-Ah;Lee, Hyun-Soo;Han, Byung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.333-335
    • /
    • 2005
  • The simulation of electric field distribution of discharge tube with globular $ZrO_2$ and the removal characteristic of Escherichia coli by the discharge tube with globular $ZrO_2$ were estimated. The removal characteristic of Escherichia coli was related to the input voltage because the electric field is increased according to input voltage. As the particle size of $ZrO_2$ beads increased, the removal time of Escherichia coli was shortened due to the dielectric polarization of $ZrO_2$ beads.

  • PDF

Characteristic Analysis of a Hybrid Stepping Motor by Change of Teeth Shape (하이브리드 스테핑 모터의 치형상 변화에 따른 특성 해석)

  • Ahn, Ho-Jin;Kang, Gyu-Hong;Hong, Jung-Pyo;Kim, Gyu-Tak;Lee, Jong-Bae;Sung, Ha-Gyeong;Lim, Tae-Bin
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.138-140
    • /
    • 2001
  • In hybrid stepping motors, the shape of teeth is most important design variable which have critical influence on output characteristics. This paper deals with the characteristic analysis by change of teeth shape and present a improved model. FEM(Finite Elecment Method) and EMCM(Equivalent Magnetic Circuit Method) are used for analysis.

  • PDF

Analysis of Torque Characteristic Considering The Dimensional Tolerance of BLDC Motor (치수공차를 고려한 BLDC 전동기의 토크 특성 해석)

  • Kim, Young-Kyoun;Hong, Jung-Pyo;Hur, Jin;Sung, Ha-Kyong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.750-752
    • /
    • 2003
  • This paper presents a method of tolerance analysis for a electric machine. Tolerance analysis technique is required to find the tolerance band of design variables and estimate the characteristic distribution of the electric machine, because that manufacturing tolerances as well as measuring errors have a great influence on the electric machine. Therefore, this paper introduces Stochastic Response Surface Methodology to achieve the tolerance analysis. As an example, the tolerance analysis is applied to the analysis of torque characteristics for a BLDC motor from the electric point of view.

  • PDF

The Hydraulic simulation and removal characteristics of Escherichia Coli for Ultraviolet rays.Ozone sterilization apparatus (자외선.오존 살균소독장치의 유체시뮬레이션 및 대장균 제거 특성)

  • Hwang, In-Ah;Lee, Hyun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.169-172
    • /
    • 2005
  • The simulation of Hydraulic pressure distribution of discharge tube with globular beads and the removal characteristic of Escherichia coli by the discharge tube with globular beads were estimated. The removal characteristic of Escherichia coli was related to the input voltage because the electric field is increased according to input voltage. As the passing amount of test water in discharge tube is increased, the removal ratio of Escherichia coli was increased because passing numbers of electric field section is increased.

  • PDF