• Title/Summary/Keyword: Electric characteristic

Search Result 1,275, Processing Time 0.03 seconds

Characteristic Analysis of Shorted-turn for Generator Rotor (발전기 회전자의 층간단락에 대한 특성 해석)

  • Kim S.J.;Jeon Y.S.;Lee S.H.;Choe G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.137-140
    • /
    • 2003
  • Shorted-turns can have significant effects on a generator and its performance. Shorted-turn sensor for synchronous generator's field winding have been developed. One of effective method detecting inter-turn short circuits on round rotor winding is a method using sensor detecting. But the method needs duplicate design of sensor for characteristic change according to types and forms of generator Thus sensing skill without sensor depend on change of electric property in generator. For the reason, this paper presents shorted-turns phenomenon and the characteristic analysis of shorted-turns In synchronous generator by using 2-D finite element method(FEM).

  • PDF

Design and Characteristic Experiment of Eddy Current Coupling (와전류 커플링의 특성 실험 및 설계)

  • Jang, Seok-Myeong;Cho, Seong-Kook;Lee, Sung-Ho;Ji, Seung-Kun;Ryu, Ki-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.110-112
    • /
    • 2003
  • Electric control of eddy coupling offers many new possibilities in process control and other industrial control applications. And a form of speed control for the load is affected for a system driven by costant frequency induction motor. This paper analysis speed-torque characteristic of the eddy-current coupling by using the 3-dimensional analytical method. Characteristic experiment is put into operation for the claw pole type eddy current coupling. Design procedure is presented based on the analysis.

  • PDF

A Study on the Operating Characteristic of RCB by Synthesize Harmonic Current (복합고조파에 의한 누전차단기의 동작 특성 연구)

  • Yoo, Jae-Geun;Choi, Myung-Il;Park, Chee-Hyun;Son, Jae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.1
    • /
    • pp.59-63
    • /
    • 2008
  • This paper analyze the operating characteristic of RCB due to the synthesize harmonic current. The RCB of rated sensitivity electric current with 30[mA] test to operating characteristic by synthesize harmonic current and it analyzed the tripping operation due to a harmonic current. The test result, the operating current of RCB changed by synthesize harmonic current.

Finite Element Analysis of BLDC Motor Characteristic according to Magnetic Property Measurement Methods (자성 측정 방법에 따른 BLDC 전동기의 전자계 특성해석)

  • Kim, Ji-Hyun;Ha, Kyung-Ho;Kwon, Oh-Yeoul;Cha, Sang-Yoon;Kim, Jae-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.697-698
    • /
    • 2008
  • This paper deals with finite element characteristic analysis of brushless DC motor according to magnetic property measurement methods. Magnetic property data for non-oriented (NO) electrical steel for electric motors are measured by the Epstein test which is considered as the international standards. Data from Epstein test may result in discrepancy from motor characteristic tests due to innate anisotropic property of NO electrical steel. Finite element analysis were performed for a BLDC motor by various measurement methods such as Epstein test, Ring test and single sheet test (SST), and calculated results were compared with considering anisotropic property conditions.

  • PDF

Sensorless Diagnosis Method and Characteristic Analysis of Short-Circuited Turn for Generator Rotor (발전기 회전자의 층간단락 센서리스 진단기법 및 특성 해석)

  • Kim Sun-Ja;Jeon Yoon-Seok;Lee Seung-Hak;Choe Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.210-213
    • /
    • 2003
  • Short-circuited can have significant effects on a generator and its performance. One of effective method detecting inter-turn short circuits on round rotor winding is a method using sensor detecting. But the method needs duplicate design of sensor for characteristic change according to types and forms of generator. Thus rotor shorted-turn diagnosis method without sensor is needed for detecting short turn when generator is driven. Diagnosis method without sensor depend on change of electric property in generator For the reason, this paper presents characteristic analysis of shorted-turns in generator by detecting the output voltage of generator.

  • PDF

The operation Characteristic of Pilot-scale 2-Stage Coal gasifier (Pilot 규모 2단 형상 가스화기 운전특성 실험)

  • Hong, Jin-Pyo;Chung, Jae-Hwa;Seo, Seok-Bin;Chi, Jun-Hwa;Lee, Seung-Jun;Chung, Suk-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.528-532
    • /
    • 2009
  • Integrated Gasification Combined Cycle (IGCC) power plant converts coal to syngas, which is mainly composed with hydrogen and carbon monoxide, by the gasification process and produces electric power by the gas and steam turbine combined cycle power plant. The purpose of this study is to investigate the influence of gasification process to type and structure of gasifier. For this purpose, the performance characteristics of gasification reaction are analyzed with the operation characteristic of pilot-scale 2-stage coal gasifier. It is found that gasification reaction, floating characteristic of melted slag, particle stick of inside of the gasifier, particle stick and deposit of Syngas cooler are the causes in the different performance characteristics.

  • PDF

Analysis of Sheath Induced Voltage and CCPU Operating Characteristic in Underground Transmission Cable (지중송전계통에서 시스유기전압 및 CCPU 동작 특성 해석)

  • Jin, Hye-Young;Lee, Jong-Beom;Kim, Young;Cho, Han-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.494-496
    • /
    • 2001
  • This paper describes sheath induced voltage and operating characteristic of cable cover protection unit(CCPU) in underground transmission cable. Real cable system operating by 154kV XLPE cable was modelled for simulation. Sheath induced voltage and operating characteristic of CCPU were analyzed. In particular, sheath induced voltage was analyzed in case of individual grounding and common grounding, respectively, and operating characteristics of CCPU were compared each other.

  • PDF

E.M.F Characteristic of 30kVA class Superconducting Synchronous Generator according to Magnetic shield length (30kVA급 초전도 동기 발전기에서 축방향 길이 변화에 따른 유기기전력 특성연구)

  • Jo, Young-Sik;Hong, Jung-Pyo;Kim, Gyu-Tak;Kwon, Young-Kil;Ryu, Kang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.85-87
    • /
    • 1998
  • In general, we apply the 2 dimensional method to analyze the characteristic of electric machinery. But it is very difficult to analyze the air-cored machine like as superconducting generator, because it have 3 dimensional flux distribution. In this paper, we compare the analysis r between 2D and 3D. 3D Finite Element Meth applied to the superconducting generator at n condition. And we studied the characteristic acc to the axial length of magnetic shield.

  • PDF

A Study on Environmental Characteristic of Insulators for Ultra High Voltage Using ESDD and NSDD Measurement (초고압애자의 ESDD 및 NSDD 측정을 통한 내환경 특성 연구)

  • Lee, Sang-Yun;Lim, Yun-Seog;Lee, Won-Kyo;Lee, Dong-Il;Shin, Koo-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2095_2096
    • /
    • 2009
  • 송배전용 설비에 사용되는 애자의 신뢰성은 전기적인 절연성질과 기계적인 내구성 뿐만 아니라 애자가 설치된 송전선로의 오손에 의한 내환경성에 의해서도 결정될 수 있다. 지금까지 염분 및 분진이 심한 지역에서 오손물이 애자에 미치는 영향에 대한 연구는 전기적, 기계적 신뢰성에 영향을 미치는 오손물질의 성분 분석 등을 통해 저압과 고압의 환경에서 진행되어 왔다.[1] 본 논문에서는 2003년부터 우리나라에서 운전해 오고 있는 765kV 애자오손 신뢰성 검토와 미국 전력연구원(EPRI)에서 수탁받은 765kV 고분자애자 특성연구의 일환으로, 765kV 상용선로에 사용되는 애자류에 대한 장기열화특성을 연구하기 위해 765kV 실증 시험설비를 구축하였다. 아울러, 765kV 애자 장기열화특성 분석을 위한 기초연구로 염분 및 분진 오손도를 측정하여 765kV 환경에서 애자종류에 따른 오손 특성을 검토하였다. 그 결과, RTV 실리콘고무 코팅 애자가 자기 및 유리재 애자에 비해 염분 오손도 면에서 비교적 우수한 특성을 지님을 확인 할 수 있었다.

  • PDF

A Reliability Model of Wind Farm Considering the Complex Terrain and Cable Failure Based on Clustering Algorithm

  • Liu, Wenxia;Chen, Qi;Zhang, Yuying;Qiu, Guobing;Lin, Chenghui
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1891-1899
    • /
    • 2014
  • A reliability model of wind farm located in mountainous land with complex terrain, which considers the cable and wind turbine (WT) failures, is proposed in this paper. Simple wake effect has been developed to be applied to the wind farm in mountainous land. The component failures in the wind farm like the cable and WT failures which contribute to the wind farm power output (WFPO) and reliability is investigated. Combing the wind speed distribution and the characteristic of wind turbine power output (WTPO), Monte Carlo simulation (MCS) is used to obtain the WFPO. Based on clustering algorithm the multi-state model of a wind farm is proposed. The accuracy of the model is analyzed and then applied to IEEE-RTS 79 for adequacy assessment.