Impedance Calculation of an Underground Transmission Cable System Installed with a Sheath Current Reduction Device

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won;Wang, Xin Heng;Song, Yong Hua
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권4호
    • /
    • pp.236-242
    • /
    • 2004
  • Previous research results indicated that the designed current reduction device could effectively reduce the sheath circulating current and that its RDP protection device could shield it against both fault and lightning strokes. In this paper, cable impedance is analyzed using wavelet analysis and distance relay algorithm following the installation of these devices so that the operation of distance relay can be estimated. The test results confirm that in these devices, the fault inception angle and SVL bonding types have no impact on the change of cable impedance. In other words, the conventional distance relay can be used without a new relay setting. Thus we can finally assert that the designed current reduction device and its protection device are effective and can be safely installed on the cable transmission system without disturbance.

케이블 열회로의 전기적 등가회로 변환을 이용한 케이블 허용전류 검토 방법 (A Review Method of Calculation Results on Cable Ampacity using the Transformation to Electric Equivalent Circuit from Cable Thermal Circuit)

  • 강연욱;김민주;장태인;박진우;박흥석;강지원
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.738-744
    • /
    • 2016
  • Current rating of a power cable can be calculated by the maximum allowable temperature in an insulating material considering the heat transfer from cable conductor. Therefore, it is very important to calculate the current rating using electrical equivalent circuit by calculated cable thermal circuit parameters but, it has not been fully investigated yet. In this paper, in order to determine the current rating of power cable, conventional calculation method has been reviewed considering the conductor resistance, loss factor of sheath, dielectric losses and thermal resistances based on the maximum allowable temperature of 345 kV $2500mm^2$ XLPE cable. To confirm the calculation result of the current rating, the conductor temperature should be examined whether it reaches the maximum allowable temperature by the thermal equivalent circuit of the cable. Then, utilizing EMTP (Electro-Magnetic Transient Program) which is a conventional program for electrical circuit, the thermal equivalent circuit was transformed to an electric equivalent circuit using an analogous relationship between thermal circuit and electrical circuit, and temperature condition including cable conductor, sheath, cable jacket could be calculated by the current rating of 345 kV $2500mm^2$ XLPE cable.

Halogen Free 난연 케이블의 제특성 및 개발 (Properties and Development of Halogen Free Flame Retardant Cable)

  • 최원규;최웅;서세종;양호진;원준희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.768-770
    • /
    • 1992
  • Conventional flame retardant cable using PVC or CR materials generate considerable amount of toxic and acidic gas (HCI etc.) together with excessive black smoke during a fire. The newly developed halogen free materials have dissolved the problem of halogen acid gases. This paer describes the development of this power cable insulation and sheath, using halogen free materals.

  • PDF

대지전위와 통신회선 잡음 발생에 대한 고찰 (A Study on the Generation of the Earth Potential and Communication Line Noise.)

  • 여상근;박찬원
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.33-38
    • /
    • 2007
  • This paper presents a experimental evidence of the generation of the earth potential and communication line noise from the electric railway. There is a critical measurement err in case of measuring the electrical power induced noise voltage and degree of cable balance in the field of earth potential generated. As a results, it has been found that the conventional cable has more noise immunity than shielded cable near the railway where the earth current flows through the sheath layer.

  • PDF

활선 6 kV CV 단심 케이블의 도체 및 표면온도 측정 데이터에 관한 타사 데이터와의 비교검토 (Comparison and Examination of the Measured Data With the Data from Other Company for the Conductor and Sheath Temperatures of Live 6 kV CV Single Core Cables)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.197-201
    • /
    • 2017
  • 국내의 전기수요량은 매년 증가하고 있다. 발전소에서 전력을 생산하고 공급하기위하여 채택된 모든 장비들은 신뢰할 수 있는 상태에서 완전하게 동작하여야 한다. 생산된 고전압의 전기를 공급하기 위한 장비로서 6 kV CV 단심케이블이 사용되고 있다. 케이블 제작사는 케이블의 동작 수명이 약 30년 이라고 공개적으로 알리고 있다. 그러나 설치된 케이블이 동작을 시작함과 동시에, 성능이 악화되는 열화과정이 시작된다. 동작 중인 케이블의 열화 상태로 인한 신뢰성을 진단을 받지 않았기 때문에, 케이블은 예측하지 못하는 시점에서 언제든지 파괴될 수 있다. 우리는 케이블의 사고를 체계적으로 감시 및 예방하기 위한 측정 장비를 개발, 한국서부발전 주식회사(Korea Western Power Co. Ltd.)에 설치하여 활선 케이블을 진단하였다. 이 논문에서 우리는 케이블을 구성하고 있는 도체와 표면온도를 측정하였고, 타사의 데이터와 비교하여 서로가 일치한다는 연구결과를 제시한다.

지중케이블 선로 임피던스 실측 및 분석 (Measurement and Analysis of Line Impedance in Underground Cables)

  • 하체웅;김정년
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.205-207
    • /
    • 2003
  • The line impedance is important data that is applied in all analysis fields of electric power system like power flow, fault current, stability and relay calculation etc. Usually, impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding wires, and earth resistance. Therefore, if there is a fault in cable system, these terms will severely be caused much error to calculation of impedance. Therefore, the line impedance were measured for this study in an actual power system of underground cables, and were analyzed by a generalized circuit analysis program EMTP for comparison with the measured value. These analysis result is considered to become foundation of impedance calculation for underground cable.

  • PDF

발전소에서 운전 중인 활선 6 kV CV 단심 cable의 도체온도에 따른 피복 표면온도 및 부하전류 특성 분석 (Analysis of Sheath Temperatures and Load Currents Dependent on Conductor Temperatures in Live 6kV CV Cables Operating at a Power Station)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.189-195
    • /
    • 2017
  • 발전소의 발전기에서 생산된 전기를 외부 단자로 공급하기 위하여 유일하게 사용되는 수단은 6 kV CV 단심 cable이다. 발전소에서 발생하는 여러 종류의 사고들 중에서 cable의 열화로 인한 화재 사고는 막대한 사회 경제적 손실을 초래한다. 설계부터 시공 및 관리를 더욱 철저히 해야 한다. 설치환경 및 사용 조건 부하량 등에 따라 차이가 있겠지만, 증설과정, 부적절한 설계 등으로 인하여 cable의 단면적이 부족할 경우가 발생하며, 운전 전류에 의하여 초과된 허용온도는 cable의 열화 상태를 초래한다. 우리는 cable의 사고를 체계적으로 감시 및 예방하기 위한 측정 장비를 개발, 한국서부발전 주식회사(Korea Western Power Co., Ltd.)에 설치하여 활선 cable을 진단하였다. 이 논문에서 우리는 cable이 설치되어 있는 주위환경 특히, 주위 온도에 따라 변동하는 cable의 피복표면의 온도를 측정하고 이에 따른 부하 전류를 검토한 결과를 제시한다. 실제 예로서 주위 온도가 $40^{\circ}C{\sim}10^{\circ}C$의 경우에 피복의 표면 온도와 부하전류의 특성을 연구한 결과를 제시한다.

지중송전케이블계통에서 절연통의 과전압 해석 및 억제대책 검토 (Analysis of Overvoltage and Reduction Methods of Insulation Joint Box in Underground Power Cable Systems)

  • 홍동석;정채균;이종범;서재호;조한구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권2호
    • /
    • pp.102-108
    • /
    • 2002
  • This paper describes the overvoltage analysis and reduction methods of insulation joint boxes in underground transmission power cables when direct lightning surge strikes to overhead transmission line. An actual 154kV combined transmission line with underground Power cables was modelled in ATPDraw for simulation. Simulations were performed to analyze the overvoltage between insulation joint boxes, sheath-to-ground voltage according to the distance between cable conductors, cable lengths, burying types, CCPU connection types. The most effective method to reduce the induced overvoltage of Insulation joint boxes was proposed. It is evaluated that the proposed reduction method riven from the detailed simulations can be effectively applied to the actual underground power cable systems.

대지전위와 통신회선 잡음.발생에 대한 고찰 (A Study on the Generation of the Earth Potential and Communication Line Noise)

  • 여상근;박찬원
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.181-189
    • /
    • 2007
  • 본 논문에서는 전기철도에서 발생하는 대지전위와 통신회선의 잡음에 대한 실험적 증명에 관한 것이다. 대지전위차가 발생하는 곳에서 전력유도잡음전압과 케이블 평형도 등을 측정할 경우 계측 오차가 심각하게 발생되는 것으로 나타났다. 측정결과, 고속철도 인접한 곳의 통신케이블은 시스층에 지전류가 많이 흐르는 차폐 케이블보다 일반 케이블을 그대로 사용하는 것이 잡음피해를 보다 줄일 수 있음이 실험 결과로 확인 되었다.

발전소에 포설된 케이블 선로 임피던스 분석 (Line Impedance Analysis of Underground Cable in Power Plant)

  • 하체웅;한성흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.612-613
    • /
    • 2007
  • The line impedance is important data that are applied in all analysis fields of electric power system such as power flow, fault current, stability and relay calculation etc. Usually, the impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, the impedance can not be accurately calculated because cable systems have the sheath, grounding wires, and earth resistances. Therefore, if there is a fault in cable system, these terms will severely be caused many errors for calculating impedance. In this paper, the line impedance is measured in a power system of underground cables, and is analyzed by a generalized circuit analysis program, EMTP(Electromagnetic Transient Program), for comparison with the measured value. These analysis results are considered to become foundation of impedance calculation for underground cables.

  • PDF