• 제목/요약/키워드: Electric breakdown

Search Result 688, Processing Time 0.039 seconds

A Study on Displacement Current Characteristics of DMPC Monolayer (II) (DMPC 인지질 단분자막의 변위전류 특성 연구 (II))

  • Song, Jin-Won;Lee, Kyung-Sup;Choi, Yong-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.343-348
    • /
    • 2007
  • The physical properties of DMPC monolayer were made for dielectric relaxation phenomena by the detection of the surface pressures and displacements current. Lipid thin films were deposited by accumulation and the current was measured after the electric bias across the manufactured MIM device. It is found that the phospolipid monolayer of dielectric relaxation takes a little time and depend on the molecular area. When electric bias is applied across the manufactured MIM device by the deposition condition of phospolipid mono-layer, it wasn't breakdown when the higher electric field to impress by increase of deposition layers.

Methodology of Parallel Ground Conductor Installation on Underground Transmission System (지중송전 시스템의 병행지선 설치 방안 연구)

  • Hong, Dong-Suk;Park, Sung-Min;Hahn, Kwayng-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.470-471
    • /
    • 2008
  • SVL is installed at underground transmission system to protect cables and insulation joint-box from overvoltages caused by lightning, switching, and line-to-ground fault. Domestic underground power system adopts cross bonding type to reduce the induced voltage at sheath, but single-point bonding is required depending the system installation configuration. SVL can be easily broken by overvoltages induced at joint-box because single-point bonding has uneffective system structure to extract fault current. ANSI/IEEE recommends Parallel Ground Continuity Conductor(PGCC) to prevent SVL breakdown. In this paper, EMTP simulation is performed to analyze effects on SVL under PGCC installation when single-line-to-ground fault occurs. The result shows that PGCC and short single-point bonding distance can reduce overvoltages at SVL.

  • PDF

Analysis of Breakdown of 170kV GIS in a vacuum due to transmission line inducted voltage (송전선로 유도전압으로 진공중인 170kV GIS의 절연파괴 사례분석)

  • Kim, Jin-Hwan;Seo, Jung-Chul;Park, Han-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.54-56
    • /
    • 2008
  • 전력계통에서 사용하는 고전압급의 차단기의 절연은 대부분이 SF6 GAS를 사용하고 있으며 (22.9kV급에서는 진공차단기가 주종을 이룸) 운전중 압력은 약 $3.6-6.0kg/cm^2$이다. 내부점검을 위해서는 무압상태에서 Gas를 회수장치에 옮겨 보관후 작업을 수행한다. 그러나 다시 Gas를 용기(容器)내로 담아 넣기 위해서는 진공(眞空)하여야 하는 공정이 필요하며,. 이 과정의 진공은 진공초기 단계정도로 절연내력을 가지는 진공상태라 할 수 없다. 진공작업과정에 발생한 고장사례를 통해 전기절연 상애의 선행 조건이 어떠해야 하는지 살펴보고자 한다.

  • PDF

Electrohydrodynamic (EHD) Enhancement of Boiling Heat Transfer of R113+WT4% Ethanol

  • Oh Si-Doek;Kwak Ho-Young
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.681-691
    • /
    • 2006
  • Nucleate boiling heat transfer for refrigerants, R113, and R113+wt4% ethanol mixture, an azeotropic mixture under electric field was investigated experimentally in a single-tube shell/ tube heat exchanger. A special electrode configuration which provides a more uniform electric field that produces more higher voltage limit against the dielectric breakdown was used in this study. Experimental study has revealed that the electrical charge relaxation time is an important parameter for the boiling heat transfer enhancement under electric field. Up to 1210% enhancement of boiling heat transfer was obtained for R113+wt4% ethanol mixture which has the electrical charge relaxation time of 0.0053 sec whereas only 280% enhancement obtained for R113 which has relaxation time of 0.97 sec. With artificially machined boiling surface, more enhancement in the heat transfer coefficient in the azeotropic mixture was obtained.

Displacement Current Characteristics of DMPC Lipid Monolayer (DMPC 인지질 단분자막의 변위전류 특성)

  • Choi, Yong-Sung;Sang, Jin-Won;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.12-13
    • /
    • 2006
  • The physical properties of DMPC monolayer were made for dielectric relaxation phenomena by the detection of the surface pressures and displacements current. The current was measured after the electric bias across the manufactured MIM device. It is found that the phospolipid monolayer of dielectric relaxation takes a little time and depend on the molecular area. When electric bias is applied across the manufactured MIM device by the deposition condition of phospolipid mono-layer, it wasn't breakdown when the higher electric field to impress by increase of deposition layers.

  • PDF

The development of computational fluid dynamics tools for thermal expansion type interrupter with the arc rotary (아크회전과 열팽창 방식을 적용한 소호부에 대한 아크유동 해석)

  • Choulkov, Victor;Lee, B.W.;Seo, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.813-815
    • /
    • 2000
  • This paper is concerned with the development of PC based computer simulation and design tools for auto-expansion SF6 circuit breaker with the arc rotary. The simulation model takes into account radiation transport, turbulence enhanced momentum. energy transport. The conversation gas dynamic equation together with Maxwells equations are solved. For the arc simulation the straightforward procedure has been used. The temperature, gas density and velocity space distributions within the circuit breaker are simulated in details. The presented results show that the computer simulation of gas flow in SF6 interrupter is a subject of much interest for design and optimization of contacts. The presented results show that the shape and sizes of contacts are chosen by this tool from judiciously compromise between electrical breakdown strength and interruption ability that are functions of gas flow parameters.

  • PDF

Study on Insulation Prediction of Triple Junction in $SF_6$ ($SF_6$ 가스 중의 삼중점 절연파괴 예측기술에 관한 연구)

  • Cho, Yong-Sung;Chong, Jin-Kyo;Lee, Woo-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.989-993
    • /
    • 2009
  • Triple junction which consists of three media(electrode, insulator, and gas) should be considered in designing of high voltage equipments due to the electric field enhancement. In this paper, positive lightning impulse breakdown voltage is predicted based on the streamer theory for simplified insulator models and 72.5kV spacer with varying the triple junction geometry and gas pressure, and the results are compared to the experimental results. The electric field coefficient concept is also applied in order to evaluate the partial discharge inception voltage and the surface flashover voltage from the streamer inception voltage. The application of this method using the constant electric field coefficient of 1.3 and 0.66 is possible for evaluating the triple-junction insulation of the simplified insulator and the 72.5kV spacer respectively. The error rate is under 10%.

Estimation of the Feeding Line Capacity according to Feeding Mehtod (급전방식에 따른 급전선로의 전송용량 예측)

  • Lee, Chang-Mu;Lee, Han-Min;Oh, Se-Chan;Kim, Gil-Dong;Jang, Gil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1169-1170
    • /
    • 2007
  • The primary objective of this paper is to examine the capacity of electrical transmission in electric railway according to the type of feeding system. Although supply capacity of railway substation are sufficient and there is no accident, due to the electrical transmission limit of feeding line the voltage breakdown may occur when large capacity of electric load at feeding line exist. So, using multi-port analysis model, we draw P-V curve due to feeding method, load, location and power factor of electric locomotive.

  • PDF

A Study of LA Counter Over-activation in AC Electric railway Substation (AC 전철변전소의 피뢰기카운터 과동작에 관한 연구)

  • Cheon, Hee-Seung;Jang, Woo-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.132-139
    • /
    • 2008
  • In an electric railway feeding system, transient over-voltage often appears due to the feeder's direct lightning and induced lightning, while switching over-voltage also frequently occurs during operation of electric feeding in substation facilities. Such over-voltage is several times larger than the regular power, and accordingly leads to the dieletric breakdown of eletric power products such as invasion transformers and circuit breakers. Arresters are installed to protect these machines, while arrester counters are installed to observe the arrester's activation. This thesis aims to explore the status of an arrester counter that is being activated several thousand times, determine whether the arrester has actually been activated in relation to the counter, and investigate the over-heatedness and risks of the arrester.

  • PDF

Variation in Properties of Seawater Flooded and Non-Flooded CSPE (해수범람 전·후의 CSPE 특성변화)

  • Lee, Jeong-U;Kim, In-Yong;Ji, Seong-Hyun;Jeon, Hwang-Hyun;Shin, Yong-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1724-1729
    • /
    • 2015
  • Chlorosulfonated polyethylene (CSPE) was not flooded seawater and flooded seawater & freshwater for 5 days, respectively, and these samples are referred to as BSF(before seawater flooding) and ASFF(after seawater & freshwater flooding), respectively. The apparent density, dissipation factor, relative permittivity, melting temperature, dielectric breakdown time and increased time of applied voltage are higher than those of BSF, but the insulating resistance, dielectric strength, percent elongation and glass transition temperature of ASFF are lower than those of BSF. The differential temperature of those is $0.026{\sim}0.028(^{\circ}C)$ after AC and DC voltage is applied to ASFF, respectively, and the differential temperature of those is $0.013{\sim}0.037(^{\circ}C)$ after AC and DC voltage is applied to BSF, respectively. In the case AC and DC voltage is applied to ASFF as well as BSF, the variations in temperature of AC voltage are higher than those of DC voltage. It is investigated that dielectric loss due to dissipation factor ($tan{\delta}$) is related to electric dipole conduction current. It is certain that the ionic (electron or hole) leakage current was increased by conducting ions such as $Na^+$, $Cl^-$, $Mg^{2+}$, $SO_4^{2-}$, $Ca^{2+}$ and $K^+$, those are related to cured atoms of O and S that relatively increased after seawater flooding.