• Title/Summary/Keyword: Electric arc

Search Result 560, Processing Time 0.026 seconds

Recovery of manganese compounds from electric arc furnace dust by Aluminothermy Process (테르밋 반응을 이용한 페로망간 전기로 분진의 재활용에 관한 연구)

  • Ha, Tae-Young;Jo, Young-Min;Park, Young-Koo;Kim, Youn-Che
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • The properties of dust collected from electric arc furnace of ferro manganese production units was investigated, and also the metallic manganese was recovered from the dust by aluminothermy process. The ferromanganese dust collected from electric arc furnace contained about 15% of manganese oxide ($Mn_3O_4$) and 9% of carbon as the contaminant, and have a 5um of 50% median diameter and irregular particle shape. The carbon contaminant in the dust could be reduced until about 0.1~0.5% level by roasting in the air at a temperature of 600~900C for 60minutes. The recovery of manganese could not be carried out using only ferromanganese dust from electric arc furnace by aluminothermy process, but the ferromanganese which contained manganese of about 92% and iron of about 5% could be obtained from the mixture of ferromanganese dusts from electric arc furnace and converter. The best mixing condition of dust fixed at electric arc furnace dust / converter dust ratio of 1:9 and 2:8, and the mixing rato of 3:7 or more could not separated the metal and slag from the reactant after aluminothermy reaction.

Experimental Study on the Bond Capacity of RC Beams Using Electric Arc Furnace Oxidizing Slag Aggregates (콘크리트용 전기로 산화 슬래그 골재를 사용한 RC 보의 부착 성능에 관한 실험적 연구)

  • Ryu, Deug-Hyun;Lim, Ji-Young;Lee, Yong-Jun;Kim, Sang-Woo;Kim, Kil-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.5
    • /
    • pp.581-588
    • /
    • 2009
  • An amount of electric arc furnace slag, by-products generated in iron manufacture, is being increased. Therefore, it is required to recycle the electric arc furnace slag. Currently, it is possible to use the electric arc furnace slag as the aggregates of the concrete through the insurance of volume stability but not in the past because of the expansibility of f-CaO and f-MgO. In this study, simple beam tests via Ichinose method were performed to estimate the bond properties of reinforced concrete (RC) beams using the electric arc furnace slag. The results of the test showed that the showed that specimens using the electric arc furnace oxidizing slag aggregates have similar or more bond capacity relative to the specimen of natural aggregates. Especially, bond capacity of the specimens using the slag aggregates was almost one and a half times higher than a specimen using natural aggregates.

Development of Catenary Arc Detection System (전차선 아크 검측 시스템 개발)

  • Song, Sung-Gun;Lee, Teak-Hee;Cho, Seong-Jae;Moon, Chul-Yi;Park, Seong-Mo
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.1
    • /
    • pp.37-43
    • /
    • 2010
  • Catenary (Overhead Contact Lines) and Pantograph are used to transmit electrical energy to electric railways. An Arc occurs by unstable contact between catenary and pantograph during electric railways operation, which causes malfunctioning or even an accident. Therefore, to prevent a arc or electric contact loss are required arc detection systems with catenary maintenance capability. This paper describes developing of catenary arc detection system using photo detector in order to detect arc incidence in a indirect way. This developed system can also achieve Video-recordings and environmental conditions such as wire voltage/current, pantograph height, speed, position of electric railways, and temperature/humidity. This system have been evaluated at the section that bounds for dongdaegu from seoul. From the experimental results, the occurrence of arc and intensity of arc are mainly effected by wire voltage/current, pantograph height and speed of electric railways.

Accelerated Aging of Electric Arc Funace Slag with CO2 Nano Bubble by X-Ray Diffraction (X-선 회절 분석을 통한 CO2 나노버블수 침지 전기로 슬래그 촉진 에이징 검토)

  • Lim, Chang-Min;Im, Geon-Woo;Kim, Young-Min;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.61-62
    • /
    • 2023
  • In this study, the steel slag was immersed in CO2 nano-bubble water by Electric arc funace it was accelerated aging was reviewed through XRD analysis. The main minerals of the electric furnace oxidized slag were spinel and gehlenite, and there was no change with the number of CO2 nano-bubbles. Minerals such as larnite, calcio-olivine, agnetite, calcite, and spinel were distributed in electrically reduced slag, and the content of calcite more than doubled with CO2 nano-bubble immersion. Therefore, it is judged that the acceleration aging of Electric arc funace reduced slag is effective according to the immersion of CO2 nano-bubble.

  • PDF

Simulation of Fault-Arc using EMTP (EMTP를 이용한 아크 사고의 모의)

  • Byun, S.H.;Choi, H.S.;Chae, J.B.;Kim, C.H.;Han, K.N.;Kim, I.D.;Kim, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.850-852
    • /
    • 1996
  • High impedance fault (HIF) is defined as fault that general overcurrent relay can't detect or interrupt, Especially when HIF occur under 15 kV, energized high voltage conductor results in fire hazard, equipment damage or personal threat. Because most HIF occur arc, HIF detection using arc is to increase. Numerical arc model can be applied in an electromagnetic transients program (EMTP) to reproduce the dynamic and random characteristic of arcs for any insulator arrangement, current and system voltage. It allows the representation of any network configuration to be investigated, so the digital simulation of arc faults through air can be substitute for demanding power arc test.

  • PDF

AFCI algorithm design without sensor (센서없는 AFCI 알고리즘 설계)

  • Ban, Gi-Jong;Choi, Sung-Dai;Ho, Yoon-Kwang;Kim, Sang-Hoon;Nam, Moon-Hyon;Kim, Lark-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.231-233
    • /
    • 2006
  • Arc Fault Current is an electric discharge which is occurred in two opposite electrode. In this paper, arc current control algorithm is designed for the interruption of arc fault current which is occurred in the low voltage network. This arc is one of the main causes of electric fire. General arc current sensor has troubles for detecting arc currents, thus we would like to propose the arc current detection method without current sensor. In this paper, arc discharge currents within power lines are being detected through the arc current control algorithm.

  • PDF

Electric Arc Furnace Voltage Flicker Mitigation by Applying a Predictive Method with Closed Loop Control of the TCR/FC Compensator

  • Kiyoumarsi, Arash;Ataei, Mohhamad;Hooshmand, Rahmat-Allah;Kolagar, Arash Dehestani
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.116-128
    • /
    • 2010
  • Modeling of the three phase electric arc furnace and its voltage flicker mitigation are the purposes of this paper. For modeling of the electric arc furnace, at first, the arc is modeled by using current-voltage characteristic of a real arc. Then, the arc random characteristic has been taken into account by modulating the ac voltage via a band limited white noise. The electric arc furnace compensation with static VAr compensator, Thyristor Controlled Reactor combined with a Fixed Capacitor bank (TCR/FC), is discussed for closed loop control of the compensator. Instantaneous flicker sensation curves, before and after accomplishing compensation, are measured based on IEC standard. A new method for controlling TCR/FC compensator is proposed. This method is based on applying a predictive approach with closed loop control of the TCR/FC. In this method, by using the previous samples of the load reactive power, the future values of the load reactive power are predicted in order to consider the time delay in the compensator control. Also, in closed loop control, two different approaches are considered. The former is based on voltage regulation at the point of common coupling (PCC) and the later is based on enhancement of power factor at PCC. Finally, in order to show the effectiveness of the proposed methodology, the simulation results are provided.

Development of a Mixed Chaotic Electric Arc Furnace Model (전력 품질 해석을 위한 개선된 전기아크로 모델 개발)

  • Jang, Gil-Soo;Wang, Weiguo;Lee, Byongjun;Kwon, Sae-Hyuk
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.2
    • /
    • pp.90-95
    • /
    • 2001
  • Electric arc furnaces (EAFs) has a process to cause the degradation of the electric power quality such as voltage flicker. In order to adequately understand and analyze the effects on the power system from these loads, obtaining an accurate representation of the characteristics of the loads is crucial. In this paper, a mixed chaotic EAF model to represent the low frequency and high frequency variations of the arc current respectively has been proposed. The Lorenz system may contribute to the low frequency components of arc current and the logistic equation may contribute to the high frequency components, and the proposed mixed model will be a combination of both Lorenz and logistic model. The concept of chaotic parameters, such as chaotic resistance, inductance of admittance has been also proposed for the characterization of arc furnace operation and the highly nonlinear physical processes. The power quality indices are calculated from the simulated waveforms and compared with the actual power quality indices statistics in order to illustrate the model's capabilities.

  • PDF

A Study on Auxiliary Control Safety Apparatus for RCD Trip on Electric Arc and Spark Disasters - Using by Power Semiconductor Switching Device - (아크 및 스파크 재해에 대한 누전차단기 트립을 위한 보조제어 전기안전장치에 관한 연구 - 전력용 반도체 스위칭 소자 적용 및 응용 -)

  • Kwak, Dong-Kurl;Shin, Mi-Young;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.71-76
    • /
    • 2006
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with electrical faults. Residual Current Protective Device(RCD) of high sensitivity type used at low voltage wiring cuts off earth leakage and overload, but the RCD can't cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied low voltage distribution panel are prescribed to rated breaking time about 30[ms](KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To be improved on such problem, this paper is proposed to a auxiliary control apparatus for RCD trip on electric arc or spark due to electrical fire. Some experimental results of the proposed apparatus is confirmed to the validity of the analytical results.

A Study on the Resistance of Chemical Attack of Mortar Using the Electric Arc Furnace Slag as Fine Aggregate (전기로슬래그 잔골재를 사용한 모르터의 약품저항성에 대한 연구)

  • 문한영;유정훈;윤희경;이재준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.303-306
    • /
    • 1997
  • In this paper, we carried out the fundamental experiments on the resistance of chemical attack of mortar using the electric arc furnace slag as fine aggregate. The mortar specimens made from the electric arc furnace slag (EAF slag) as fine aggregate were immersed in artificial seawater and two sorts of chemical solutions, and measured to investigate the change of compressive strength and weight.

  • PDF