• Title/Summary/Keyword: Electric acupuncture

검색결과 122건 처리시간 0.025초

C.V.A.환자(患者)의 심장판막질환(心臟瓣膜疾患)에 대한 증례보고(症例報考) (The case report of C.V.A. patient with M.V.H.D)

  • 강민주;정지천;이원철
    • 대한한방내과학회지
    • /
    • 제14권1호
    • /
    • pp.43-54
    • /
    • 1993
  • Observing after enforcing the medication and the acupuncture theraphy on the CVA patient sick with the cerebral embolus by organic pathology of the heart and whose desease was from heat symptoms caused by exessive pathogenic factors of which caused from affection due to exogeneous factors, we obtained the results as follows; 1. Serious condition could be relieved by removing acute symptoms according to the principle of the 'In emergency causes treat the acute symptoms first, when these being relieved treat it's fundament cause'. 2. The lesion could be disable for which the traditional medication theraphy through the differentiation of symptoms-complexes had removed the symptoms caused by organic pathology of heart. 3. The acupuncture stimulation through the differentiation of symptoms seemed to influence electric conduction system. Through this case, If we objectify the diagnosis and the medical treatment, the part of the curing diseases can progress more effectively.

  • PDF

Taguchi 실험계획법을 이용한 경혈점의 피부전기특성 최적화조건 선정 : A Pilot Study (Application of Taguchi's Robust Design Method in Optimization of Measuring Electrical Properties on Acupoints: A Pilot Study)

  • 남동현;신상훈
    • Korean Journal of Acupuncture
    • /
    • 제25권3호
    • /
    • pp.15-27
    • /
    • 2008
  • Objectives : The objective of the current study is to optimize an acupoint electrical property measurement system by using the procedures and strengths of the Taguchi method. Methods : Taguchi method was applied in the optimization of the acupoint electrical property measurement system, as in the following steps: (1) determine evaluation index; (2) execute the 1st gage R&R; (3) identify controllable and uncontrollable factors; (4) design Taguchi crossed array layout; (5) execute experiments according to trial conditions; (6) analyze testing results; (7) determine optimum run; (8) execute the 2nd gage R&R; (9) confirm optimum run. Results : The results showed that electrodes with larger diameter and efferent electric current, with music played, can produce the larger different electrical conductivity between the acupoints and the non-acupoints under various conditions. Taguchi process optimization improved repeatability and reproducibility of the acupoint electrical property measurement system. Conclusions : In the optimized condition, repeatability and reproducibility of the acupoint electrical property measurement system was acceptable.

  • PDF

한의 치료로 호전된 경추성 현훈 환자 치험 3예 (Three Cases of Cervical Vertigo Improved by Traditional Korean Medicine Treatment)

  • 최성환;강신우;박현선;박서현;금동호
    • 한방재활의학과학회지
    • /
    • 제32권1호
    • /
    • pp.145-155
    • /
    • 2022
  • The purpose of this study is to evaluate the effectiveness of traditional Korean medicine treatment of cervical vertigo. Three patients were diagnosed as cervical vertigo with correlating symptoms of imbalance and dizziness with neck pain. The diagnosis of cervical vertigo is also dependent on excluding other vestibular disorders on the basis of history, examination, and vestibular function tests. They were treated by acupuncture, transcutaneous electrical nerve stimulation therapy and low-intensity pulsed ultrasound at acupoints and sympathetic ganglion chain of their cervical and upper thoracic region. The evaluation of clinical outcome was done by numeric rating scale (NRS), dizziness handicap inventory (DHI) and neck disability index (NDI), EuroQol-five dimensions questionnaire (EQ-5D) index. After the treatment, the value of their NRS, NDI, DHI was significantly decreased and their EQ-5D index was significantly increased. The traditional Korean medicine treatment at cervical and upper thoracic region could be an effective way to treat cervical vertigo.

Transcutaneous electrical nerve stimulation, acupuncture, and spinal cord stimulation on neuropathic, inflammatory and, non-inflammatory pain in rat models

  • Sato, Karina Laurenti;Sanada, Luciana Sayuri;da Silva, Morgana Duarte;Okubo, Rodrigo;Sluka, Kathleen A.
    • The Korean Journal of Pain
    • /
    • 제33권2호
    • /
    • pp.121-130
    • /
    • 2020
  • Background: Transcutaneous electrical nerve stimulation (TENS), manual acupuncture (MA), and spinal cord stimulation (SCS) are used to treat a variety of pain conditions. These non-pharmacological treatments are often thought to work through similar mechanisms, and thus should have similar effects for different types of pain. However, it is unclear if each of these treatments work equally well on each type of pain condition. The purpose of this study was to compared the effects of TENS, MA, and SCS on neuropathic, inflammatory, and non-inflammatory pain models. Methods: TENS 60 Hz, 200 ㎲, 90% motor threshold (MT), SCS was applied at 60 Hz, an intensity of 90% MT, and a 0.25 ms pulse width. MA was performed by inserting a stainless-steel needle to a depth of about 4-5 mm at the Sanyinjiao (SP6) and Zusanli (ST36) acupoints on a spared nerve injury (SNI), knee joint inflammation (3% carrageenan), and non-inflammatory muscle pain (intramuscular pH 4.0 injections) in rats. Mechanical withdrawal thresholds of the paw, muscle, and/or joint were assessed before and after induction of the pain model, and daily before and after treatment. Results: The reduced withdrawal thresholds were significantly reversed by application of either TENS or SCS (P < 0.05). MA, on the other hand, increased the withdrawal threshold in animals with SNI and joint inflammation, but not chronic muscle pain. Conclusions: TENS and SCS produce similar effects in neuropathic, inflammatory and non-inflammatory muscle pain models while MA is only effective in inflammatory and neuropathic pain models.

-침술효과 객관화를 위한 연구- 접지와 절연조건이 경락전위에 미치는 영향 (Influence on Meridians Electric Potential for Electrical Ground and Insulation)

  • 이용흠;이균정;김은근;김한성;신태민
    • 한국정보통신학회논문지
    • /
    • 제10권12호
    • /
    • pp.2243-2250
    • /
    • 2006
  • When a patient is positioned at insulated bed and practitioner is positioned at insulated floor, that condition could be a cause of lessening effect in acupuncture practice. We investigated how Ground connection and Insulation could influence on the electrical meridian potential between practitioner and patient during acupuncture practice. We treated 30 normal healthy subjects with acupuncture and measured changes in the electrical potential between the stomach meridian points ST-39 and ST-37 in response to light touch after insertion of a needle at ST-36. At first, we stimulated non-insulated needle and measured electrical potentials for non ground, patient ground only, practitioner ground only, all ground respectively. Then we used insulated needles and measured same as above. Non-insulated all ground subject elicited positive mean potential $44.6{\pm}19.2{\mu}V$ and showed $181.4{\pm}59.7{\mu}V$ peak to peak potential. Practitioner ground only showed negative mean potential of $51.5{\pm}9.3{\mu}V$ and $367.4{\pm}27.8{\mu}V$ of peak to peak potential. Patient ground only revealed no mean potential of $2.9{\pm}1.3{\mu}V$, $16.4{\pm}11.9{\mu}V$ of peak to peak potential. All ground showed no mean potential of $1.6{\pm}0.7{\mu}V$, $3.3{\pm}1.9{\mu}V$ of peak to peak potential. In case of Insulated condition, there elicited no mean potential. Non ground and Practitioner only showed weak value of peak to peak potential as $7.8{\pm}2.6{\mu}V$ and $8.4{\pm}2.5{\mu}V$ each. But patient only and all ground showed no potential as $4.7{\pm}2.2{\mu}V$, $3.4{\pm}2.2{\mu}V$, respectively. Therefore, Ground connection modulate the energy transfer course between practitioner and patient. Insulation block energy transfer but static electrical impulse between practitioner and patient.

EEG, fMRI, EAV 및 SQUID장치(裝置)를 이용(利用)한 기공현상(氣功現狀) 측정(測定) (The Studies on Qigong state Using EEG, fMRI, EAV and SQUID Measurments)

  • 정찬원;최찬헌;윤유식;소철호;나창수;장경선
    • Korean Journal of Acupuncture
    • /
    • 제21권2호
    • /
    • pp.1-28
    • /
    • 2004
  • Objectives : Human physiological changes in the state of qigong has been measured using EEG(Electroencephalography), functional MRI(functional Magnetic Resonance Image), EAV(Electro-Acupuncture according to Voll) and SQUID(Superconducting Quantum Interference Device) measurements. Methods & Results : EEGs were measured to study the differences between Qigong masters and Qi receiver on the changes of EEG. During Qigong, an alpha waves were increased. The power spectra indicate that the peak frequency of alpha waves increased during Qigong. Qi receiver's EEG signals seemed to affected by the state of himself. Brain activation did not observed when qigong master concentrates the Qi at Laogong(P8). But a localization of fMRI signal in the sensory cortex was observed by electric acupuncture stimulation at Laogong(P8). Five phase deviation of EAV were clearly changed in the both cases of Qigong master and Qi receiver. When a Qigong master concentrates the Qi at Yintang, Laogong(P8), Qihai(CV6) meridian points during Qigong state, the change of magnetic field around acupoints Yintang, Laogong points has been measured using 40-Channel DROS-SQUID apparatus. After smoothing process of the continuously measured magnetic signal around acupoints for a few minutes, we could observe that a series of peaks, magnitude of -1.0~2.5pT appeared. But there was no significant difference in changes of magnetic signal around acupoints. Physical signals of magnetocardiogram has been measured by using 2-Channel DROS SQUID(Magnetocardiogram). Physical signals of magnetocardiogram were clealy changed at the ST segments after S-wave when qigong master concentrates the Qi.

  • PDF

한방 복합치료로 호전된 경추성 현훈 환자의 증례보고 1례 (A Case Report on a Patient with Cervical Vertigo Who Improved with a Combination of Korean Medicine Treatments)

  • 황동규;김은지;최기훈;허승진;윤덕원
    • 대한한방내과학회지
    • /
    • 제38권3호
    • /
    • pp.392-400
    • /
    • 2017
  • Objective: To report the case of a patient suffering from cervical vertigo who was treated with a combination of Korean medicine treatments (including acupuncture, pharmaco-acupuncture, and Chuna manual therapy). Method: An outpatient with cervical vertigo was given a combination of Korean medicine treatments five times, from December 5 to 16, 2016. All of the treatments, acupuncture with electric stimulation and pharmaco-acupuncture, were applied on the trigger points (TP) of the cervical muscles and the upper trapezoid muscles. Chuna manual therapy was then applied on the cervical area. The Numeric Rating Scale (NRS) - according to outpatient's statement on vertigo, neck pain and headache - and the Korean Dizziness Handicap Inventory (DHI), which is a self-evaluating scale of dizziness in daily life, were used to evaluate the effects of this treatment. Results: At the end of the treatment, the vertigo and the headache disappeared. The NRS decreased from 9 to 0 for vertigo and from 5 to 0 for headache. Although the neck pain also decreased, it did not disappear; this NRS decreased from 7 to 1. The DHI score also decreased significantly, from 64 to 4. Conclusion: Since the symptoms of the patient with cervical vertigo improved after the very first treatment and the improvement of the symptoms was observed as the treatment progressed, this case report is worth supporting the efficacy of combined Korean medical treatments. However, because there was only one subject, it is hard to say that this efficacy can be generalized. Moreover, this report cannot prove the individual efficacy since various treatments were combined. While there are many researches related to cervical vertigo in Western medicine, the studies in Korean medicine are comparably insufficient; therefore, follow-up research on more subjects is needed.

부항자극에 대한 체표 경락.경혈의 생체에너지 변화 분석 (Analysis of Meridians Energy change by Cupping Stimulation)

  • 김수병;이나라;김영대;임종현;송길수;정병조;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제27권4호
    • /
    • pp.49-57
    • /
    • 2010
  • Objectives : The aim of this study is evaluation for significance of skin meridian-acupoints energy measurement system, and is verification of principle to measure the bio-ion charge on acupoints. Methods : To check a correlation between the MEP(Meridian Energy Potential) and bio-electric charge condition, ten acupoints(left/right BL meridian : BL13, BL15, BL18, BL20, BL23) were chosen. Based on basic theory concerning the upward trend of the bio-electric charge by cupping therapy, we measured MEP change before and after 600mmHg(80kPa) Negative pressure stimulation using cupping. Results : We could identify the correlation between MEP and the condition of bio-electric charge in acupoints. Also, we checked the balance or imbalance of left/right the MEP and unusual cases. Conclusions : We confirmed significance of proposed principle and meridian energy measurement system.

부항 장치용 압력 제어 밸브 개발 (Developing a Pressure Control Valve for Air Extraction Cupping Device)

  • 이재용;심동욱;안수광;김은석;이병렬;양기영
    • Korean Journal of Acupuncture
    • /
    • 제38권4호
    • /
    • pp.308-316
    • /
    • 2021
  • Objectives : This study aimed to develop a cupping pressure control valve for limiting maximum negative pressure while achieving clinical therapeutic outcomes to minimize side effects induced by excessive negative pressure of air extraction cupping devices. Methods : To determine the clinical necessity and suitability of the cupping pressure control valve, this study was designed to measure the change in pressure with or without the valve using both a manual and an electric suction pump. Results : While the maximum pressure was limited by the pressure control valve, the pressure did not increase above a certain level regardless of the type of manual or electric pump. Conclusions : This study will contribute to the development of a safer and more effective base technology for cupping treatment in oriental medicine.

진공압을 이용한 한방 하이브리드 멀티 전동 부항 콘텐츠에 관한 연구 (A Study on Oriental Medicine Hybrid Multi-cup Electric Cupping Contents using Vacuum Pressure)

  • 김종찬;위통순;고재섭;최흥국;탁명자;김치용
    • 한국멀티미디어학회논문지
    • /
    • 제17권11호
    • /
    • pp.1363-1373
    • /
    • 2014
  • In this study, a hybrid multi-cup electric cupping system (HMECS) was proposed, based on the ancient cupping method. HMECS consisted of several cups that could be used simultaneously to treat different areas of the patient's body. Each cup was equipped with its own pump and pressure-monitoring system. Moreover, the vacuum pressure of the cups was controlled using fuzzy logic. Through automated control of the vacuum pressure, long-term relief of muscle tightness was achieved. To develop a scientific foundation for this alternative treatment, we compared the VAS(Visual Analog Scale) and ODI(Oswestry Disability Index) scores from conventional basic cupping to the VAS and ODI scores for our proposed HMECS. The improvement rate in the VAS and ODI scores using HMECS after three treatments was higher than that achieved by basic cupping. These results, combined with the convenience offered by enhanced IT capabilities, should increase the popularity of this device among an aging society, and facilitate the opportunity to further explore the potential of Oriental medical practices.