• Title/Summary/Keyword: Electric Wires

Search Result 181, Processing Time 0.035 seconds

Fire Cause Analysis of Local Heating on Carbon Type Hot Wire Electric Pad (카본열선을 사용하는 전기장판의 국부가열에 의한 화재원인 분석)

  • Song, Jae-Yong;Kim, Jin-Pyo;Nam, Jung-Woo;Sa, Seung-Hun
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.104-108
    • /
    • 2010
  • This paper describes electrical fire on electric pad using carbon type hot wires. A carbon type hot wires electric pad is virtually impossible to connect hot wire as a method of electrical welding or soldering. In order to connect between hot wires, that has to splice carbon type material connector. If junction of hot wires was occurrence of poor connection on electric pad, it increase contact resistance on this junction point. With increasing contact resistance, junction of hot wires on electric pad generates local heating and finally leads to electrical fire. In this paper, we analyzed shape of damage in hot wires caused by electrical local heating and investigated fire cause on electric pad using by carbon type hot wires.

Fire Cause Analysis on Electric Pad Due to Defect of Hot Wires (전기장판 열선 결함에 의한 전기화재 원인분석)

  • Song, J.Y.;Sa, S.H.;Nam, J.W.;Kim, J.P.;Cho, Y.J.;Oh, B.Y.
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.2
    • /
    • pp.7-12
    • /
    • 2012
  • This paper describes electrical fire on electric pad caused by defect of hot wires. We analyzed two type electric pad using by carbon type hot wire and magnetic shielded type hot wire. First, a carbon type hot wires electric pad is virtually impossible to connect hot wire as a method of electrical welding or soldering. In order to connect between hot wires, that has to splice carbon type material connector. If junction of hot wires was occurrence of poor connection on electric pad, it increase contact resistance on this junction point. With increasing contact resistance, junction of hot wires on electric pad generates local heating and finally leads to electrical fire. An electric pad using by a magnetic shielded type hot wire happened local heating on signal wire for sensing temperature-rise caused by applying current for magnetic shielded. With increasing local heating of signal wire, insulated coating of hot wire was melted. Finally the magnetic shielded type hot wire electric pad lead to electrical fire with breakdown between signal wire and hot wire. In this paper, we analyzed shape of damage in hot wire caused by electrical local heating and investigated fire cause on electric pad due to defect of hot wires.

A Study on Deterioration Diagnostic Method for Electrical Wires of Electric Multiple Units (도시철도차량 전선에 대한 열화진단 방법 고찰)

  • Hong, Yong-Ki;Chung, Jong-Duk;Pyun, Jang-Sik
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.680-687
    • /
    • 2009
  • Several kinds of Electrical Wires have been used in Electric Multiple Units(EMU) for the supply of electric power, supervision, and the propagation of control signals. These Electrical Wires must be inspected for safe and stable operation of EMU. The degradation diagnosis to estimate the integrity of Electrical Wires has recently been requested according to the long use of EMU. This paper describes on application of diagnosis method for EMU.

  • PDF

Field Application of Recycled Aluminum Wires (재생 ACSR 전선의 실계통 적용)

  • Kim, Ju-Yong;Kim, Sang-Joon;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1396-1398
    • /
    • 1997
  • This paper presents experimental results on the recycling aluminum wires used in the actual field. Several testings were carried out with the recycled aluminum wires to prove that they are reusable. Mechanical, electrical and oxidation properties of recycled and new ACSR $160\;mm^2$ were campared after 7.5 year service aging at the salt comtaminated areas of Korean peninsular.

  • PDF

Fatigue Life Prediction for Electric Railway Catenary wires (가선재의 피로수명 예측)

  • Kim, Yong-Ki;Chang, Se-Ky
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.558-567
    • /
    • 2003
  • The catenary wires are damaged by periodic running of train as well as repeated stress. The wires are also degraded by atmosphere corrosion at fields. Corrosion of wires increased surface roughness and deteriorated mechanical properties by providing fatigue crack initiation sited resulting in a bad effect on service life of the wires. Fatigue test of catenary wires performed to estimate service lifetime. Also, simulation to analyze stress on catenary wires was conducted through modelling the finite elements for dynamic behaviors of wires. Fatigue life of catenary wires was estimated with fatigue and simulation tests.

  • PDF

Magnetic Field Properties About Core Change (코어 변화에 대한 자계 특성)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.159-164
    • /
    • 2012
  • In this paper, it tried to develop the core sensor for detection of micro magnetic field in electric wires. The sensor is non contact type and is consisted of ferrite core for low price. To investigate their properties for variations of current, it changed the number of winding and the length of sample core, it examined, to check the live wire situation in built-in wires, electrical characteristics due to difference between electric wires and core sensor. As the results, it verified live wire situation at the number of winding(5,000) and within length of 6[cm]. Also, it obtained magnetic field magnitude decreased inverse proportion ratio to a square about difference between electric wires and core sensor.

Preventing Method against the Occurrence of a Corona between a Dead End clamp and a Porcelain Insulator Used in 154kV Substation

  • Han, Woon-Ki;Choi, Jong-Soo;Lee, Jun;Kim, Jae-Chul
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.22-26
    • /
    • 2007
  • An episode of corona is a heterogeneity-caused electric discharge that occurs when electric fields are formed layer on layer and concentrated on an electrode. Electric wires built at the tip of 154kV private facilities use dead end clamp spawns corona from homogeneity caused by field concentration. Corona induces power loss, noise, insulator failure and more. In this research, we've studied the characteristics of coronas that take place in porcelain insulators and terminal electric wires of supporting hard wares (dead end clamp) that are set up as spares in the 154kV private facilities use hydroelectricity installations to support electric wires. Corona, which cannot be identified by regular methods, was measured utilizing UV image camera. As the result of measuring corona via UV image camera, we've confirmed that the depletion of insulators was accelerated following the wire end treatment method and validated the stress intensity of insulators at various lengths of bare wires caused by electric fields via FEMLAB. We have also proposed a new model for relieving homogeneity-caused field concentration, and after analyzing the proposed model via FEMLAB, we've confirmed that the concentration of field distribution was indeed reduced. Such results are exploited in installation of private facilities use equipments, maintenance of insulators and hard wares as well as safety enhancement, and are anticipated to be effectively utilized in corona prevention measures.

The Effect of Corrosion on the Fatigue Life of Catenary Wire (부식에 의한 가선재 수명특성에 관한 연구)

  • 김용기;장세기;이덕희;정병철
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.139.1-146
    • /
    • 2001
  • Contact lines are necessary to supply electric locomotives with electric power. As most railways are gradually electrified with modernized electric cars, the demand for catenary wires and their facilities are also increased. Catenary wires made by metallic materials are generally used in the open air. They are exposed to the marine area with air-borne salt or severely polluted industrial area with much corrosive emission gases depending on the railway locations. In urban area, acid rain may cause a degradation of catenary wire system. Corrosion of catenary wires can make their actual lifetime shorter than that originally designed. Thus, the messenger wires, a kind of catenary wire system, were investigated with respect to corrosion, which include new and the used one collected at the field. They are also vibrated with some amplitude everytime the train passes through the railway. The frequent cyclic load on the wire any result in a fatigue damage, Surface damage by corrosion can make fatigue crack initiate with ease. In the present study, the fatigue life of the used wire was measured 40 to 50% shorter than that of new one in average.

  • PDF

Development of a Technique for Detection of Contact Wire Wear using High-Speed Camera (고속카메라를 이용한 전차선 마모 검측 영상처리 알고리즘 개발)

  • Park, Young;Cho, Yong-Hyeon;Cho, Chul-Jin;Kim, Won-Ha
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.8
    • /
    • pp.632-637
    • /
    • 2010
  • The measurement of contact wire wear in electric railways is one of the key test parameters to increase speed and maintain safety in electric railways. Wear caused by continuous interaction between pantographs and contact wires has a negative effect on current collection quality and severely damaged contact wires might cause hazardous accidents. This paper introduces a non-contact optical-based contact wire wear measuring system that will replace conventional wear detecting methods conducted by maintenance vehicles or workers. The system is implemented by high-speed cameras that can collect images of contact wires during vehicle operation, a laser used to create images profile of the contact wire surface, and a computer used to process the collected images. The proposed system is designed to assist maintenance of overhead contact lines by creating geometrically plotted images of contact wires to detect contact wire wear during operation on conventional lines or high-speed lines.

A Study on Ignition and Fire Risks of Electric Heat Wire (전기적 열선의 발화 및 화재 위험성에 관한 연구)

  • Min, Se-hong;Song, Byeong-jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.113-121
    • /
    • 2015
  • This study aims to examine the risk of electrical fire in places where electric heat wires are used. In general, the use of electric heating wires is becoming more common and prevalent in a bid to prevent increasing damage caused by freezing and bursting in residential water pipes, factory pipes and irrigation pipes in vinyl greenhouse and a variety of heat wire products are available in market with legal safety requirements imposed on them. However, the widespread use of anti-freezing burst heat wire products has caused increasing incidents of fire, which often fail to be incorporated into statistics due to quick onsite extinguishing and insignificant damage although damage is gradually on the rise. Against this backdrop, this study aims to look into the possibility of ignition caused by electric heat wires and the mechanism of how it turns into catching fire through overheat and short circuit tests for anti-freezing burst electrical heat wires (hereinafter called the 'heat wire') and expects to serve as the basis for further observations and analyses on the cause of fire and the process of ignition in a scientific manner.