• 제목/요약/키워드: Electric Shock Protection

Search Result 45, Processing Time 0.031 seconds

Applying Cases of Manipulator for Live Working on Internal and External Distribution Lines (국내외 배전 활선작업 Manipulator 적용현황)

  • Kim, Jae-Hoon;Kim, Seung-Ho;Kim, Dae-Sik;Park, Kang-Sik;Lee, Heung-Ho;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.118-120
    • /
    • 2005
  • Nowadays, economical and social environments are changing to the type of an advanced country for development of techniques in power industry. So most of workers are recently avoiding the 3D works and asking for safety of working environment, etc. in highly dangerous parts such as hot line working on distribution lines, especially. Therefore, most advanced countries are using the support-arm or robotic systems on distribution line works for securing the construction reliability, economical feasibility and protection of linemen from the electric shock and so forth. In special Japanese electric power companies are using the robotic system named manipulator. In Korea, a support-arm has been developed for safety and facility in live working on distribution lines but not widely supplied. In this paper we will introduce development cases of support arm and manipulator robot for live working on distribution lines.

  • PDF

A Study on the Safety Assessment and Damage Pattern of Water Purifier Compressors (정수기용 압축기의 안전성 평가 및 소손 패턴 분석에 관한 연구)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.21-25
    • /
    • 2013
  • The purpose of this study is to provide basic data for the safety assessment of a water purifier when water leaks due to inappropriate maintenance and the examination of the cause of accidents related to the leak. Due to its inspection and management by non-specialists, if a leak occurs in a water purifier with the water level controller being inclined, it may result in the failure of the compressor, power supply line, PCB, etc. The analysis of the thermal diffusion pattern of water purifier compressors using a thermal image camera shows that its maximum temperature was approximately $80^{\circ}C$. In addition, its operating current was a maximum of 13 A and the system's operating current was approximately 1.7 A after the compressor was charged. It was found that the housing type power cable cover of the compressor had the effect of preventing electric shock but has poor flame resistance. Furthermore, the performance of the overload protector, PTC relays, etc., was excellent but they have potential for problems as metallic terminals were exposed, resulting in the potential of a safety related accident. The terminals and their surface damaged by the tracking showed a trace of carbonization and the resistance between terminals was measured to be approximately $8{\Omega}$. In addition, while the tracking was proceeding, the fuse and circuit breaker installed for system protection did not operate.

Study to Analyze the Grounding System in the 20 kHz Power Installation (20 kHz 전력설비 접지시스템 분석에 관한 연구)

  • Jung, Jin-Soo;Han, Woon-Ki;Park, Chan-Urm;Song, Young-Sang;Lim, Hyun-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1308-1312
    • /
    • 2013
  • In this paper, carried out for optimal ground system for ensuring safety for electricity used to power equipment in the 20 kHz frequency. Now the grounding system of the mesh electrode, electrode rods are installed for power plant safety and protection against electric shock. However, the electrical equipment grounding system in the 20 kHz were considering the increasing grounding impedance due to the high frequency and the magnetic shielding. But until now, there has been little research on the grounding system. To solve this problem, In this paper was proposed optimal grounding system due to the experiment using a mesh electrode, rod electrode, aluminum plate electrodes. Measurement results, grounding resistance was depending on the material of the electrode grounding resistance. In addition, the leakage current (induced) appeared to be affected depending on the type of electrode.

Quench characteristics of YBCO thin films using magnetic field source for superconducting fault current limiters

  • Lee, B.W.;Park, K.B.;Kang, J.S.;Oh, I.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.11-14
    • /
    • 2004
  • YBCO thin films have good characteristics for current limiting materials due to compact size and high current carrying capability. But the irregularities and the extreme thin thickness of YBCO films cause some difficulties in simultaneous quench and thermal shock protection. In order to solve these problems, vertical magnetic field generated from solenoid coil was applied to the YBCO element. And also to minimize the inductance caused by the serial connection of magnetic field source with superconducting elements, magnetic field source was separated from the power lines adapting protective current transformer. In this study, electric field-current (E-I) and quench characteristics of YBCO films were analyzed both by electrical measuring method and observations of bubble propagation. From the experiment results, it was revealed that the magnetic fields generated by surrounding coil could induce the uniform quench distribution for all stripes of current limiting units and finally simultaneous quenches were realized in all serial connection of YBCO elements. In addition, the separation of magnetic field source form electrical network could be good solution for simultaneous quench of YBCO films without any unnecessary effect caused by serial connection.

A Study on the Method of Resistance Analysis of Water Stream During Fire Supperession (화재진압 시 발생하는 주수 기둥의 저항분석 방법 연구)

  • Jung, Byeong-Sun;Kim, Eung-Sik;Park, Jong-Yeol
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.22-27
    • /
    • 2018
  • Fire fighters are exposed to the risk of many accidents during fire suppression, especially near the high voltage circuit. In order to prevent and analyze the electric shock accidents, measurement of water resistance is crucial. However, this has been one of the overlooked research areas and it has been very difficult to measure the mixed up resistance components separately. In this paper, we measured a total resistance of apparatus and regarded it as a serial resistance of contact resistance and length dependant resistance. Measuring the resistance by varying the length of water stream, the variable resistance and fixed contact resistance appear, which are used to calculate the both components of resistances. In addition, the resistance of fire hose can be calculated from the parallel circuit which is formed by grounding the fire hose with the resistance of water stream. Results show that we can successfully measure the resistance per unit length of water stream and fire hose, thereby proving that this method is a facile way to measure water and fire hose resistance. However, many experiments are still required to obtain the precise contact resistance of ground under various condition and the resistance between the human body and fire hose.

EMC/LVD Compatibility Evaluation of ITER AC/DC Converter Subrack by EN 61000 and IEC 61010 (ITER AC/DC Converter 서브랙의 EN 61000 및 IEC 61010에 의한 EMC/LVD 시험평가)

  • Shin, Hyun-Kook;Oh, Jong-Seok;Song, In-Ho;Suh, Jae-Hak;Choi, Jung-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.222-226
    • /
    • 2021
  • To comply with CE marking requirements, the electromagnetic compatibility (EMC) and low-voltage directive (LVD) tests are conducted on the sub-racks of International Thermonuclear Experimental Reactor (ITER) AC/DC converters and bypass switches. The EMC tests consist of a series of tests, including the electromagnetic interference test, the electromagnetic field immunity test, and the rapid transient burst immunity test. In the LVD test, the electric shock protection test, the xcessive temperature limit and heat resistance of equipment tests, and the fire spread prevention test are performed. This work presents and reviews the European Directive for EMC/LVD and introduces the methods of EMC and LVD tests for the sub-racks of AC/DC converters and bypass switches. It also evaluates the test method and results to meet the European Directive requirements for CE marking. The sub-racks of ITER AC/DC converters and bypass switches successfully pass the EMC and LVD tests.

Study on the Thermal Design of Nuclear Battery for Lunar Mission (한국형 달 탐사용 원자력전지의 열제어 구조 연구)

  • Hong, Jintae;Son, Kwang-Jae;Kim, Jong-Bum;Park, Jong-Han;Ahn, Dong-Gyu;Yang, Dong-Yol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.4
    • /
    • pp.271-277
    • /
    • 2016
  • For a stable electric power supply in the space, nuclear batteries have been used as the main power source in a spacecraft owing to their long lifetime and high reliability. In accordance with the plan for lunar mission in Korea, nuclear batteries will supply electricity to the rover that needs to be developed. According to the information about the estimated payload, Korea Atomic Energy Research Institute started with the conceptual design based on the previous studies in USA and Russia. Because a nuclear battery converts the decay heat of the radioisotope into electricity, thermal design, radiation shield, and shock protection need to be considered. In this study, two types of nuclear batteries, radial type and axial type, were designed according to the alignment of the thermoelectric module. Heat transfer analyses were performed to compare their thermoelectric efficiency, and test mockups were fabricated to evaluate their performances.

The Investigation and Analysis of Field Condition on Flood Protection Equipment of Transformer Vault in Flood Area (침수지역에서 수·변전설비 침수방지시설에 관한 현장실태 조사 및분석)

  • Kim Gi-Hyun;Kim Chong-Min;Kim Sun-Gu;Hwang Kwang-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.85-90
    • /
    • 2005
  • Inundation of Transformer Vault breaks out every summer season in low-tying downtown and low-tying shore by localized heavy rain, typhoon and tidal wave. In case inundation of Transformer Vault, it occurs a great economic loss owing to recovery time and events of electric shock occur by inundation electrical facility. So we need installation plan of Transformer Vault in common flood area for preventing from economic loss and equipment events. Therefore we research distribution of 22.9[kV] Transformer Vault in common flood of the country and analyze field condition about flood protection plan. And we analyze regulation or law relating to the flood protection counterplan of US, England, Australia. This paper will be used to present a reform proposal of electrical related law about flood protection of existing Transformer Vault. Also we present considering facts at the time Transformer Vault installation in common flood area.

The development for flooding prevention apparatus of electrical equipment using air pressure (공기압을 이용한 전기설비 침수 방지 장치 개발에 관한 연구)

  • Kim, Gi-Hyun;Jean, Hyun-Jae;Lee, Sang-Ick;Bae, Suk-Myong;Lee, Jae-Yong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.281-284
    • /
    • 2008
  • Inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical equipment(Pad-mounted Transformer and Switch). In case of installing the power equipment at flood danger territory, we are necessary to the product development, the product is that water does not come in the inside the power equipment. Product of pressure maintaining are established on the basic frame and sensor operates at the flooding occurrence and is maintained a shutting tightly structure and it is a method. The product which is produced the reliability of the product it confirmed a flooding yes or no from the condition which puts in the water tank and it verified. We estimate that loss cost which is caused by with flooding and the power failure will be diminished if it is addition to advances the reliability evaluation and a security of the flood protection product.

  • PDF

Development of a Standard Checklist for Protection to Electrical Accidents of Laboratory (연구실 전기사고방지를 위한 표준체크리스트개발)

  • Lee, Dong-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.3
    • /
    • pp.108-115
    • /
    • 2011
  • This paper informs the standard guideline of electrical inspection for the University laboratories and R&D institutes. A routine electrical inspection is there to prevent an electric shock and electrical fire accident in the Lab. The main issue of this paper is to check the problem of a routine electrical inspection and this paper provides a detailed guideline of a checklist for the Lab which do not have detailed instruction. It mentions the standard model of an effective routine inspection to upgrade the weak electrical environment in the Lab. One of the main purposes of this paper is to develop a routine checklist to control the electrical environment in the Lab. The evaluation checklist we develop will then be applied to every Lab. Introducing an electrical safety checklist builds a clear standard guideline for a real safety check. This will be used as a regular routine check-up for every Lab. The goal of this paper is to enforce safety from electrical accidents in the lab and it will provide safety guidelines for every Lab.