• 제목/요약/키워드: Electric Shock Protection

검색결과 45건 처리시간 0.024초

저전압에서의 감전보호에 관한 연구 (A Study on the Protection of Electric Shock, in Low Voltage)

  • 이재인
    • 한국안전학회지
    • /
    • 제4권1호
    • /
    • pp.83-90
    • /
    • 1989
  • Recently, due to the increase of 220V distribution lines and equipments preventive measures to cope with several kinds of electric accidents is revealed as an urgent problem. This study investigates the following matters; the cause and present condition of e1ectric shock accident, the influence of electric shock on human body, the safety limit of electric shock, the method of distribution voltage, the insulation of electrical load apparatus, the teachnics of electric shock prevention and foreign materials concerned with this subject etc. This paper present the fundamental cause of electric shock and syntbetic preventive counter measure of electric shock, too.

  • PDF

건설업에서의 감전재해 감소 방안을 위한 연구 (A Study on the Decreasing Method of Electric Shock Accident in the Construction Industry)

  • 최상원
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.28-33
    • /
    • 2014
  • Regarding the characteristics of fatal electric shock accident during the past 10 years, fatalities occurred more frequently in July & August, and AM 10-12 PM & 14-16. Also, the electric shock accident is occurred more frequently in the age group from 30 to 40. Especially, the fatal electric shock accident in construction industry covered more than half of total industry. Therefore, it is strongly requested for the protection technology of an electric shock from the low voltage electric path, grounding method and workers. The aim of this study is to propose the policy about the equipment performance standards and/or worker's safety standards to revise the standards for preventing electric shock accidents on safety workings.

저압직류 접지시스템의 지락경로 흐름 분석에 따른 감전 보호기법 (Protection Techniques Against Electric Shock in Low Voltage DC Grounding Systems Depending on the Analysis of Earth Fault Current Paths)

  • 김동우;임용배;이상익;최명일;문현욱
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.232-238
    • /
    • 2016
  • This paper presents protection techniques against electric shock in low voltage DC(direct current) grounding systems depending on the analysis of earth fault current paths. Firstly, the comparison between alternating current and direct current on human was conducted, and current threshold values for each current path and for long duration were analyzed. Secondly, the analyses of the earth fault current flows were performed depending on the grounding types and earth fault conditions. Lastly, based on these analyses, adequate protection measures of electric shock depending on low voltage DC grounding types were provided.

최근 감전재해의 발생특성과 재해원인 분석연구 (A Study on the In-depth Analysis of Cause and Characteristic for Recent Electric Shock Accident)

  • 최상원
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.7-11
    • /
    • 2014
  • The electric shock victims were predominantly male, and more than half of the victims were found in companies with less than five employees in terms of the scale of company, and also more than half of victims had less than one month of experience for work experience. Considering the category of industry, more than half of the victims were engaged in construction, and considering the subcategory of industries, more than 60% of electric shock victims were found in building and other construction works. This study intended to conduct an in-depth analysis on the cause of electric shock accidents to provide basic data for policy proposing taking into considering the characteristics such as the electric shock path, low voltage, grounding and protection of workers. Also this study conducted an in-depth analysis of electric shock accidents for the past eleven years taking into account the necessity of a long-term plan.

직류환경에서 인체에 흐르는 감전전류 분석 (Analysis on Electric Shock Current in DC Electricity)

  • 이진성;김효성
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.254-259
    • /
    • 2016
  • Recently, DC distribution systems have become a hot issue because of the increase in digital loads and DC generation systems according to the expansion of renewable energy technologies. To obtain the practical usage of DC electricity, safety should be guaranteed. The main concerns for safety are twofold: one side is human protection against electric shocks, and the other is facility protection from short faults. "Effects of current on human beings and livestock" (IEC 60479) defines a human body impedance model in electric shock conditions that consists of resistive components and capacitive components. Although the human body impedance model properly works in AC electricity, it does not well match with the electric shock behavior in DC electricity. In this study, the contradiction of the human body impedance model defined by IEC 60479 in case of DC electricity is shown through experiments for the human body. From the analysis of experimental results, a novel unified human body impedance model in electric shock conditions is proposed. This model consists of resistive components, capacitive components, and an inductance component. The proposed human impedance model matches well for AC and DC electricity environments in simulation and experiment.

스위스 치즈 모델을 적용한 철도 감전사고 발생형태에 관한 연구 (A Study on the Form of Electric Shock Accident Using Swiss Cheese Model)

  • 유기성;김재문
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1711-1716
    • /
    • 2018
  • Unlike conventional transmission and distribution lines, catenary system for operating electric railway vehicles are composed of multi-conductor groups (feeder line, contact wire, messenger wire, protection wire) and are used for railway employees, public or passengers in the station yards. Electric shock hazards are exposed and electric shocks such as death or serious injury are occurring in electric railway vehicles, railway high-voltage distribution lines, and catenary system. In order to analyze the types of electric shock accidents on railway by systematic approach method, we modeled 'unsafe behavior classification' method using swiss cheese model. Based on this method, we derived the type of electric shock accidents about railway accidents during the last 5 years by analyzing the frequency of occurrence of human errors and unsafe acts, laws and regulations related to violations, and so on.

보안등의 감전 위험성에 관한 실태조사 (A Research on the Actual Conditions of the Electric Shock Hazard of a Guard Lamp)

  • 장태준;정연하;노영수;곽희로;최충석
    • 조명전기설비학회논문지
    • /
    • 제19권4호
    • /
    • pp.32-38
    • /
    • 2005
  • 본 논문에서는 보안등의 감전 위험성의 실태를 파악하기 위하여 세 지역에서 보안등을 조사하였다. 취득된 데이터에 의거하여 보안등의 실태를 감전 위험성 측면에서 정밀하게 분석하였다. 조사결과, 많은 보안등은 규정이 미비하여 올바르게 설치되어 있지 않기 때문에 감전의 위험성이 증가되는 것으로 밝혀졌다. 따라서 감전 예방의 관점에서 보안등 시설의 설치 및 관리에 대한 구체적인 규정을 설정하는 것이 필요하다.

연료전지 자동차 세계기술규정의 감전보호기준 연구 (Research on Standards for Protection against Electric Shock in Global Technical Regulations of Fuel Cell Vehicle)

  • 황보천;이규명;유경준
    • 한국수소및신에너지학회논문집
    • /
    • 제21권3호
    • /
    • pp.167-183
    • /
    • 2010
  • This paper analyzes the backgrounds of the standards for protection against electric shock in Global Technical Regulations (GTR) of Fuel Cell Vehicle (FCV). Targets on research were high voltage criteria, safety current, isolation and grounding resistance, time limitation, energy, adequate clearance, and test procedure. Based on human impedance and effect of current in IEC 60479-1, safety of human was examined. Then, isolation and grounding circuit model of FCV were analyzed theoretically. The results give several suggestions: touch voltage less than 25V, AC energy less than 0.0813J, separation considering middle finger length, grounding resistance less than $0.2\Omega$, maximum AC ground voltage of 1V (rms), and isolation resistance between earth and electrical chassis. In MATLAB/Simulink environment, error characteristics of isolation resistance measurement procedure using internal DC sources were analyzed under variations of internal resistance of voltmeter and isolation resistance.

국내 소규모 건설현장의 전기설비 및 작업환경 분석 (Analysis of Electrical Equipment and Work Environment for Domestic Small-Scale Construction Site)

  • 김두현;황동규;김성철;강신욱;최상원
    • 한국안전학회지
    • /
    • 제29권4호
    • /
    • pp.42-47
    • /
    • 2014
  • This paper is aimed to investigate and analyze of characteristic for electrical equipment and work environment for the small-scale site. In order to investigate and analyze electrical equipment and work environment for preventing electric shock disaster in construction sites, 50 small-scale construction sites and 12 large-scale construction sites are selected. This paper completed site investigations of low-voltage equipment and the portable electric machine and equipment in 12 large-scale construction sites and 50 small-scale construction sites. The findings were about the electric shock environment relevant to the ground-relevant equipment, the panel board, the protection tools, the sockets, the temporary wiring system, the portable and movable electric machines and equipments in small-scale construction sites. Finally, this study analyzed the domestic and foreign relevant standards and regulations and these findings can be utilized as educational data warning electric shock risk caused by electric equipment in small-scale construction site.

TT, TN접지계통의 감전보호 성능평가 (Performance Evaluation of Protection against Electric Shocks for TT and TN Systems)

  • 이복희;최영철;유재덕;신희경;양순만;김태기;이주철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.315-318
    • /
    • 2009
  • Electric shock is the accident caused by the current through a person or animal's body. That is characterized by the physiological effects. In this paper, we evaluate performance of protection against electric shocks for TT and TN grounding systems which are used by a low voltage consumer nowadays. The performance of protection against electric shocks for TT grounding system is very excellent in equipotential area of the third class grounding, but the performance is poor outside the equipotential area. The performance of protection against electric shocks for TN grounding system is excellent because the potential difference is less than 50V. Accordingly, the performance of protection for TN grounding system is good as compared with that for TT grounding System.

  • PDF