• 제목/요약/키워드: Electric Resistivity

검색결과 443건 처리시간 0.032초

반도전 재료를 이용한 Resistivity grading 방식의 XLPE절연 전력케이블용 시험단말에 관한 연구 (A study on the application of testing termination for XLPE Power Cable by Resistivity Grading Method Using Semi-conductive material)

  • 이창영;신두성;;김동욱;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1105-1107
    • /
    • 1999
  • The purpose of termination for high voltage tests of XLPE power cable is to prevent flashover during the breakdown test of specimen as well as to withstand the specified voltage between its conductor and screen without failure. For easier treatment and simpler construction of testing termination, resistivity grading method using semi-conductive material was employed. Based on the fundamental theory, its failure characteristics by changing the resistivity of semi-conductive material on the insulation surface was investigated. With two layers construction by difference resistivity on their surfaces, much improved result than that of one resistivity was obtained through the experiment for MV cable.

  • PDF

필댐의 전기비저항 탐사시 전기매체에 의한 영향 분석 연구 (Interference effect by electric utilities at electric resistivity Survey of fill dam)

  • 김재홍;신동훈;임은상
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1037-1040
    • /
    • 2009
  • Using much most electricity electric resistivity survey by nondestructiveness inquiry enforcement design of country base equipment business and facilities preservation administration dimension electric resistivity survey sends and cause much effects in survey believability by electricity medium of survey personality survey contiguity that grasp base special quality by potential difference flowing current artificially in base. Is item that enforce in most in-suite although when make electric resistivity survey until present, electricity medium or effect research by electricity origination was gone much. There is shortcoming that must be difficult to know correct underground utilities establishment state in-suite in this research and do comparison examination running parallel drilling investigation to heighten believability of electric resistivity survey. Did to dam that censure data that regulate grading from construction and is censure construction which can know correctly interior base situation comparatively to electricity medium of interior and electricity eruption won of contiguity and base condition (base rock).

  • PDF

전기비저항 탐사시 지하매설물에 의한 간섭효과 연구 (Interference effect by underground utilities at electric resistivity Survey)

  • 김재홍;오병현;임은상;이종욱
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.961-965
    • /
    • 2009
  • Using much electric resistivity survey to design or preservation administration of facilities. However, By survey method that electric resistivity survey grasps special quality in base by potential difference creating artificial current in underground, Is influenced in electric resistance propensitys of various underground utilities in base. This Study selects dam 1 place that could grasp well underground situation and studied electricity interference effect by effect of underground utilities. Grasp underground utilities of dam interior, and control and observed accuracy with survey wave because various pole space. Through this Study, wish to present survey method of electric resistivity survey at design or survey of preservation administration dimension after with drawn result.

  • PDF

전기비저항탐사에서 음의 겉보기 비저항 (Negative Apparent Resistivity in Resistivity Method)

  • 조인기;김정호;정승환;서정희
    • 지구물리와물리탐사
    • /
    • 제5권3호
    • /
    • pp.199-205
    • /
    • 2002
  • 전기비저항 탐사에서 측정되는 양은 두 전위전극 사이의 전위차이다. 이 전위차가 양일 경우에는 겉보기 비저항도 양의 값을 가지며, 음일 경우에는 겉보기 비저항도 음의 값을 나타낸다. 또한 측정되는 전위차의 부호는 전기장의 방향에 따라 좌우된다. 만약 측정방향과 전기장의 방향이 같다면, 전위차와 겉보기 비저항은 양의 값을 보이게 되며, 그 반대의 경우에는 음의 값을 나타낸다. 일반적으로 지표 전기비저항 탐사에는 측정방향과 1차 전기장의 방향이 같은 전극 배열을 사용하며, 이 방향의 1차 전기장은 2차 전기장에 비하여 항상 크다. 따라서 일반적인 전극배열을 사용하는 지표 전기비저항 탐사의 경우에는 지형이 평탄하고 잡음이 없다면 음의 겉보기 비저항은 나타나지 않는다. 그러나 시추공-시추공 전기비저항 탐사의 경우에는 1차 전기장의 방향과 측정방향이 일치하지 않으며, 경우에 따라서는 1차 전기장의 측정방향 성분이 2차 전기장의 측정방향 성분 보다 그 크기가 작을 수 있다. 이 경우 2차 전기장의 방향과 측정방향이 서로 반대일 경우에는 음의 겉보기 비저항이 나타날 수 있다. 따라서 음의 겉보기 비저항은 측정방향의 1차 전기장이 매우 작은 영역에서 발생할 가능성이 높다.

모암(母岩)의 전기비저항(電氣比抵抗) 변화(變化)에 따른 외견비저항(外見比抵抗)의 변화양상(變化樣相)에 관(關)한 모형연구(模型硏究) (A Model Study on the Variation of Apparent Resistivity along with Electric Resistivity Change of Host Rock)

  • 민경덕;전명순
    • 자원환경지질
    • /
    • 제13권3호
    • /
    • pp.159-166
    • /
    • 1980
  • A model study was conducted for the investigation of apparent resistivity variation along with electric resistivity variation of host rock and dip variation of bed. Experiments were carried out for the cases of horizontal and dipping beds in a water tank by using Wenner and Schlumberger arrays and by changing salinity of water. The ratios of resistivity values of the bed to that of brine were 1 : 10, 1 : 50, 1 : 100 and 1 : 500. Natural coally-shale of $55cm{\times}35cm{\times}3.5cm$ was used as a bed for experimental model, and brine as a host rock. Equi-resistivity curves and characteristic curves were obtained for each case of the experiment. The equi-resistivity curve was drawn both on the cross section parallel to strike of bed and longitudinal section perpendicular to it. The characteristic curve was drawn on the cross section. In the case of dipping bed of different dips, the curves are parallel to the boundary of the bed in the upper part of the bed, and are inclined to the opposite direction with the same angle of the dip of bed in the lower part. We can deduce, from the equi-resistivity curves, the location, shape and dip of the bed. It is shown in the characteristic curves that when the ratio of resistivity value of bed to that of host rock increases, the slope of curves becomes steeper, location of low-resistivity zone lower, and the width of it narrower. The slope of curves also becomes steeper when dip of bed increases. We can deduce, from the characteristic curves, the ratio of resistivity values between adjacent beds. It was found out from the experiments that electric resistivity method could be applicable to prospecting for underground geology with an electric resistivity contrast of 1 : 10. This fact strongly suggests that distinction of coal from coally-shale could be possible in a certain field condition.

  • PDF

The Quantitative Evaluation of Aging State of Field Composite Insulators Based on Trap Characteristics and Volume Resistivity-Temperature Characteristics

  • Liang, Ying;Gao, Li-Juan;Dong, Ping-Ping;Gao, Ting
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1355-1362
    • /
    • 2018
  • In order to obtain a better understanding of the ageing process of the field composite insulators, it is necessary to explore a quantitative-valuation method for the aging state evaluation. And the linear relationship between volume resistivity and temperature is proposed. In this paper, the composite insulators with different lengths of operating lives from two manufacturers were tested. The relationship between trap characteristics and volume resistivity-temperature characteristics were analyzed based on Thermal Stimulated Current (TSC), volume resistivity-temperature test, Scanning Electron Microscope (SEM) and Fourier Transform Infrared Spectroscopy (FTIR). Furthermore, the application of trap characteristics in the quantitative evaluation of aging state of composite insulators was discussed. The results showed that there was a general negative correlation between the relative variation ratio of trap charges and the volume resistivity-temperature characteristics. Meanwhile, the physicochemical properties would change with the aging time, which would result in the increasing of electron traps. Combined with the TSC and volume resistivity test results, the trap characteristic thresholds which indicated the serious age of the composite insulators had been proposed.

Estimation of the zone of excavation disturbance around tunnels, using resistivity and acoustic tomography

  • Suzuki Koichi;Nakata Eiji;Minami Masayuki;Hibino Etsuhisa;Tani Tomonori;Sakakibara Jyunichi;Yamada Naouki
    • 지구물리와물리탐사
    • /
    • 제7권1호
    • /
    • pp.62-69
    • /
    • 2004
  • The objective of this study is to estimate the distribution of a zone disturbed by excavation (EDZ) around tunnels that have been excavated at about 500 m depth in pre-Tertiary hard sedimentary rock. One of the most important tasks is to evaluate changes in the dynamic stability and permeability of the rock around the tunnels, by investigating the properties of the rock after the excavation. We performed resistivity and acoustic tomography using two boreholes, 5 m in length, drilled horizontally from the wall of a tunnel in pre-Tertiary hard conglomerate. By these methods, we detected a low-resistivity and low-velocity zone 1 m in thickness around the wall of the tunnel. The resulting profiles were verified by permeability and evaporation tests performed at the same boreholes. This anomalous zone matched a high-permeability zone caused by open fractures. Next, we performed resistivity monitoring along annular survey lines in a tunnel excavated in pre-Tertiary hard shale by a tunnel-boring machine (TBM). We detected anomalous zones in 2D resistivity profiles surrounding the tunnel. A low-resistivity zone 1 m in thickness was detected around the tunnel when one year had passed after the excavation. However, two years later, the resistivity around the tunnel had increased in a portion, about 30 cm in thickness, of this zone. To investigate this change, we studied the relationship between groundwater flow from the surroundings and evaporation from the wall around the tunnel. These features were verified by the relationship between the resistivity and porosity of rocks obtained by laboratory tests on core samples. Furthermore, the profiles matched well with highly permeable zones detected by permeability and evaporation tests at a horizontal borehole drilled near the survey line. We conclude that the anomalous zones in these profiles indicate the EDZ around the tunnel.

2층 대지모델에서 대지저항률의 비율에 따른 접촉전류에 의한 감전의 위험성 분석 (Analysis of Electric Shock Hazards due to Touch Current According to Soil Resistivity Ratio in Two-layer Earth Model)

  • 이복희;김태기;조용승;최종혁
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.68-74
    • /
    • 2011
  • The touch or step voltages which exist in the vicinity of a grounding electrode are closely related to the earth structure and resistivity and the ground current. The grounding design approach is required to determine the grounding electrode location where the hazardous voltages are minimized. In this paper, in order to propose a method of mitigating the electric shock hazards caused by the ground surface potential rise in the vicinity of a counterpoise, the hazards relevant to touch voltage were evaluated as a function of the soil resistivity ratio $\rho_2/\rho_1$ for several practical values of two-layer earth structures. The touch voltage and current on the ground surface just above the test electrode are calculated with CDEGS program. As a consequence, it was found that burying a grounding electrode in the soil with low resistivity is effective to reduce the electric shock hazards. In the case that the bottom layer soil where a counterpoise is buried has lower resistivity than the upper layer soil, when the upper layer soil resistivity is increased, the surface potential is slightly raised, but the current through the human body is reduced with increasing the upper layer soil resistivity because of the greater contact resistance between the earth surface and the feet. The electric shock hazard in the vicinity of grounding electrodes is closely related to soil structure and resistivity and are reduced with increasing the ration of the upper layer resistivity to the bottom layer resistivity in two-layer soil.

토양환경 변화와 접지저항의 상관관계 분석을 통한 접지 저항값 예측 연구 (Estimation of Grounding Resistance by Correlation Analysing Change Factors of Soil Resistivity and Grounding Resistance)

  • 최선규;이규영;문영호;심건보
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권1호
    • /
    • pp.35-40
    • /
    • 2020
  • The purpose of this paper is to improve the grounding point measurement method for the maintenance of the earth resistance of the distribution line. This study defines the correlation among humidity of the soil, the earth resistivity and the grounding resistance. Based on the results of the study, the grounding resistance value measurement should be limited to the location where the earth resistivity change is large, and the measurement time and cost can be greatly reduced.

전기비저항 수직탐사를 이용한 저수지 그라우팅 구간 평가 (Electrical resistivity survey for evaluation of reinforced region by cement grouting in dike)

  • 송성호;장의웅;김진호;김진성;김진춘
    • 지질공학
    • /
    • 제12권1호
    • /
    • pp.63-73
    • /
    • 2002
  • 누수 보강 저수지의 그라우팅 개선 구간 평가를 목적으로 물-시멘트 배합비별로 제조된 그라우트에 대하여 재령 변화에 따른 전기비저항과 압축강도 변화를 측정하였다. 동일 조건 하에서 그라우트의 농노가 증가할수록 전도도는 높아지고, 대상 매질에 그라우트가 주입되는 경우 주입 이전에 비해 비저항이 상대적으로 낮아지는 효과가 나타나므로 이를 이용한 주입 구간의 판정이 가능함을 확인하였다. 대상 매질이 서로 다른 세 지구에 대한 그라우팅 이후 전기비저항 수직탐사 결과 겉보기 비저항은 수십∼수백 ohm-m 이하로 낮아졌으며, 주입 이후 수 일이 지난 후부터는 점차 증가된 상태로 일정하게 유지되는 것으로 나타나는데, 이는 그라우트가 주입된 이후 대상 지층 내에서 굳어짐에 따른 강도 증가의 결과로 밝혀졌다.