• 제목/요약/키워드: Electric Precipitator

검색결과 41건 처리시간 0.026초

전기집진장치에서 가스의 물리적인 특성에 따른 포집구역내의 입자포집율 연구 (A Study on the Mass Collection Efficiency in Collector Step of Electrostatic Precipitator by Physical Gas Characterization)

  • 하상안;임경택;신남철
    • 한국환경과학회지
    • /
    • 제7권1호
    • /
    • pp.36-40
    • /
    • 1998
  • This study was carried out to investigate the collection Efficiency of mass in collector step at the different of physical gas characterization. This work has focused on the dependence of the collection efficiency of mass in the collector zone of a two-stage set up field with gas temperature T and the dew point tmeperature. To identify the dependence of the mass collection efficiency on the Bounded plate of the collector zone MP.k by the spectre electric resistance of dust $p_e$. and the relative humidify ${\varphi}$, 20 at- tempts have been made with three different gas temperature ($50{\circ}C, 80{\circ}C, 110{\circ}C$) at different dew point. At the specific electric resistance of dust $p_e$=$10^6{\Omega}m$ which relative humidity corresponds to $\phi$ > 15%, a easy rise of the sounded plate secluded dust mass share was measured atwain. As the result of the higher cohesion imprisonment power due to the adsorbtion of particle, the rinse of the relative humidity developed on the particle surface. Therefore, the collection efficiency of mass was not predominant the high temperature T in the collector zone, neither was the pecific ellectric resistance of dust dependent.

  • PDF

Process Evaluation for Current Ceramic Filters and Granular Bed Filters for High Temperature High Pressure Applications

  • Chung, Jin-Do
    • 에너지공학
    • /
    • 제5권2호
    • /
    • pp.138-145
    • /
    • 1996
  • The particulate collection at high temperature and high pressure (HTHP) is important on the advanced coal power generation system not only to improve the thermal efficiency of the system, but also to prevent the gas turbine from erosion and to meet the emission limits of the effluent gas. The specifications for particulate collection in those systems such as Integrated Coal Gasification Combined Cycle (IGCC) and Pressurized Fluidized Bed Combustion (PFBC) require the absolutely high collection efficiency and reliability. Advanced cyclone, granular bed filter, electrostatic precipitator, and ceramic filter have been developed for particulate collection on the advanced coal power generation system. However, rigid ceramic filters and granular bed filter among them show the best potential. The current technology of these collectors was evaluated in this paper. The experienced problems of these systems on performance, materials, and mechanical design were investigated. Ceramic candle filters has the best potential for IGCC at this moment because it has nearly the highest efficiency comparing with other filtering systems and has accumulated many reliable design data resulted from many field experiences.

  • PDF

고전압 플라즈마 전기집진기를 위한 고전압 저속 스위칭의 작동 특성 (Performance characteristics of low frequency pulsating voltage power supply for DC Plasma Electric Precipitator)

  • 정구영;전형근;오현준;노정욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.174-176
    • /
    • 2019
  • 최근 미세먼지(PM10 또는 PM2.5)로 인한 인체 유해성 및 실제 피해사례가 인터넷, TV 매체 등에 의해 화두가 됨에 따라 각종 제조, 사업장 및 발전소에서는 미세먼지 배출기준을 충족하기 위한 고효율 집진 기술이 필요로 되고 있는 상황이다. 고압 코로나 방전에 의해 미세먼지를 포집하는 고전압 하전방식 집진장치의 경우 전류를 광범위로 조절 가능하며 역전리 방지에 탁월하여 고효율의 집진이 가능하다. 본 논문에서는 기존의 다전원(펄스전원, 기본전원)을 이용한 마이크로 펄스 하전방식이 아닌 공진형 컨버터와 고압 트랜스포머, 배전압 회로를 적용한 고전압 단전원 제어 하전방식 및 이를 이용한 고전압 전압원의 저속 스위칭 제어기법을 제안하고, 실제 측정을 통해 제안 방식의 실효성을 검증하였다.

  • PDF

500MW 표준석탄화력발전소의 환경안전우선 설비운영개념 도입방안 고찰 (Study of the Environment Priority Facility Operation Concept of 500MW Standard Coal Thermal Power Plant)

  • 이갑주;정진도;김산
    • 대한안전경영과학회지
    • /
    • 제24권2호
    • /
    • pp.1-9
    • /
    • 2022
  • In korea, 500MW standard coal fired power plants were designed and operated for the initial base load, so facility stability was prioritized from facility problem to treatment, but now we needed to research for minimizing greehouse gas emissions at the operation of coal fired power plants. research on various facilities and technologies was actively conducted to reduce environment pollutants was drastically reduced, but research and attempts on coping measures in the event of a reduction facility problem were in sufficient. this study considered investigated ways to minimized pollutants by quickly responding to logic development and application of the load runback concept in case of serious problems with environmental pollutant reduction facilities such as NOx reduction selective catalytic reduction facilities, SOx reduction wet flue gas desulpherisation facilities, and TSP(Total Suspended Particles) collection low temperature electric precipitator.

핀이 부착된 와이어형 방전극의 형상에 따른 코로나 방전특성에 대한 연구 (Experimental Study on the Corona Discharge Characteristics of the Pin-plate Electrode Geometries)

  • 정성일;이재근;정동규;안영철
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.95-100
    • /
    • 2006
  • Electrostatic precipitators(EPs) have low pressure drop and high dust collection efficiency and are widely used for industrial dust collectors. The current-voltage characteristics, which are important to maintain high dust collection efficiency, depend on several factor: discharge electrode shape, gas flow property, dust loading etc. In this study, experiments are performed to investigate the current-voltage characteristics of the corona discharge of various electrode geometries and an empirical model is proposed to predict current-voltage characteristics of the corona discharge. The corona onset voltage correction coefficient$(\alpha)$ and the geometry correction coefficient$(k_g)$ are used to the conventional equation for wire-plate type discharge electrode. The corona onset voltages are -6.3kV and almost constant when the numbers of discharge pins are varied from 3 to 9. The length of discharge pins has very sensitive effects on the corona onset voltage. They are increased from -6.3 to -7.8kV when the discharge pin length are 8.5 and 4.5mm, respectively. The empirical model shows good agreement with experimental results and can predict the effects of discharge pin length and number.

A Capacitor-Charging Power Supply Using a Series-Resonant Three-Level Inverter Topology

  • Song I. H.;Shin H. S.;Choi C. H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.301-303
    • /
    • 2001
  • In this paper we present a Capacitor Charging Power Supply (CCPS) using a series-resonant three-level inverter topology to improve voltage regulation and use semiconductor switches having low blocking voltage capability such as MOSFETs. This inverter can be operated with two modes, Full Power Mode (FPM) and Half Power Mode (HPM). In FPM inverter supplies the high frequency step up transformer with full DC-link voltage and in HPM with half DC-link voltage. HPM switching method will be adopted when CCPS output voltage reaches the preset target value and operates in refresh mode-charge is maintained on the capacitor. In this topology each semiconductor devices blocks a half of the DC-link voltage[2]. A 15kW, 30kV CCPS has been built and will be tested for an electric precipitator application. The CCPS operates from an input voltage of 500VDC and has a variable output voltage between 10 to 30kV and 1kHz repetition rate at 44nF capacitive load [3]. A resonant frequency of 67.9kHz was selected and a voltage regulation of $0.83\%$ has been achieved through the use of half power mode without using the forced cut off the switch current [1]. The theory of operation, circuit topology and test results are given.

  • PDF

제어전극을 갖는 쌍극성 하전장치의 입자응집 특성 (Particle Agglomeration of a Bipolar Charging System with a Control Grid)

  • 문재덕;안창진
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권10호
    • /
    • pp.465-470
    • /
    • 2005
  • In this paper. an experimental study, for method of increasing the efficiency of electrostatic precipitator for the collection of submicron-sized particles has been studied. All AC electric field was used to induce agglomeration of bipolory charged Particles. .4 bipolar AC-agglomeration system. consisted with a multineedle-mesh discharge system with a control grid, was proposed and investigated. Systematic experiments were carried out to investigate the agglomeration ratio of the AC-agglomeration system as a function of the different grid spacings and grid resistances for the submicron particles generated from liquid prorhane gas burning. The agglomeration ratios, which indicate the particle numbers before and after agglomeration of the test particles in number concentration base, were found to be 0.87, 1.80, 3.86, 9.50 and, 11.00 times for the particle sizes of 0.3. 0.5, 0.7, 1.0, and 2.0$\mu$m at applied voltage of 3.5kV, respectively which showed that the fine particle numbers were decreased while the larger particle numbers were increase greatly.

집진기 미세먼지의 복합제진효율 평가방법 (How to Evaluate the Combined Dust Removal Efficiency of Fine Dust in the Dust Collector)

  • 강일서;이영수;김동현
    • 디지털융복합연구
    • /
    • 제20권2호
    • /
    • pp.339-344
    • /
    • 2022
  • 본 연구에서는 공장 및 대형 시설에서 사용되고 있는 전기집진장치에 대하여 미세분진이 효율적으로 얼마나 제거 될 수 있는지에 대한 내용이다. 미세분진 제거 효율을 평가한 결과는 다음과 같다. 10,000 V 에서는 Efficiency method I은 68.1 % 를 보였고, Efficiency method I는 58.6 %로 Efficiency method I의 효율 보다 낮은 효율을 보였다. 5,000 V 에서는 Efficiency method I은 57.6 %를 보였고, Efficiency method II는 51.6 %로 Efficiency method I보다 낮은 효율을 보였다. 2,500 V 에서는 Efficiency method I은 50.3 %를 보였고, Efficiency method II는 24.4 %로 Efficiency method I보다 낮은 효율을 보였다. Efficiency method I의 경우 전 분진농도와 필터 통과 후 분진농도을 활용하여 계산한 효율이다. Efficiency method II는 필터 후의 공기와 오염된 공기가 혼합되는 환경에서 조금 더 정확한 효율을 측정하기 위해 Efficiency method II를 계산하였다. Efficiency method II는 Efficiency method I보다 낮은 효율을 나타내었다. 전기집진장치 실험 결과 10,000 V에서 집진 성능이 가장 높게 나타났으며, 그 다음 5,000 V, 2,500 V의 순을 보였다.

이단식 전기 집진 장치에서 하전부의 상대 위치 변화에 따른 집진 특성 (Precipitation Characteristics with the Relative Position of the Ionizer in a Two-stage Electrostatic Precipitator)

  • 임헌찬;이덕출
    • 전자공학회논문지T
    • /
    • 제35T권2호
    • /
    • pp.66-71
    • /
    • 1998
  • 이단식 소형 전기 집진 장치는 작업 환경에서 오존 발생이 극히 적은 정극성 코로나를 널리 사용하고 있지만 이에 관한 과학적 연구보고는 적은 실정이다. 그러므로 이단식 소형전기 집진 장치의 기초 복성에 관하여 연구하였다. 모델 이단식 전기 집진 장치는 이론적 해석이 쉽고 하던부 집진부의 상대 위치를 이동시킬 수 있는 구조로 제작하여 다음의 실험적 결론을 얻었다. 하전부의 코로나 방전은 집진부 전극의 전체 강도에 영향을 받고, 집진부 후방에서의 입자 농도는 집진부의 고압전극과 접지전극 사이에서 크게 변화하고 있다. 집진효율은 집진부의 고압전극 후방이 집진전극 후방보다 높다. 측정 범위의 전 구간에서 입자농도를 적분하여 계산한 종합 접진 효율로부터 하전부의 방전극 바로 뒤에 집진부의 고압전극이 위치하는 구조가 접지전극이 위치하는 구조보다 높은 효율을 보이고 있다. 이것은 하전부와 접진부의 상대적 위치 관계가 집진 효율 특성에 영향을 미치고 있음을 알 수 있다.

  • PDF

사이클론 전처리부를 지닌 터널집진차량의 집진효율 최적화 (Dust collection optimization of tunnel cleaning vehicle with cyclone-based prefilter)

  • 정우태
    • 한국산학기술학회논문지
    • /
    • 제19권3호
    • /
    • pp.679-686
    • /
    • 2018
  • 지하철 터널 내에 축적된 미세먼지와 초미세먼지를 제거하기 위해서는 새로운 형식의 분진흡입차량이 필요하다. 따라서 최근 개발된 분진흡입차는 초미세먼지 제거를 위한 흡입시스템과 사이클론형식의 전처리부 및 전기집진기를 장착하고 있다. 본 논문에서는 집진차량의 하부에 설치된 먼지 흡입시스템이 다양한 크기의 먼지입자를 효과적으로 흡입하고 처리하기 위해 사이클론형식의 전처리부가 포함된 집진시스템을 설계하고 집진효율을 ANSYS FLUENT의 전산유체해석을 통해 확인하였다. 흡입구와 사이클론형 프리필터가 연결된 격자모델을 기반으로 공기유동과 상차분모델(Discrete Phase Model)을 이용하여 다양한 입자의 크기와 종류 및 흡입팬의 용량에 따른 입자의 거동을 해석하였다. 다양한 입자의 크기와 종류, 흡입팬의 용량에 대해서 해석결과 집진차량의 운영속도 5km/h에서 미세먼지처리를 위해서는 흡입팬의 용량 $1500m^3/min$에서 흡입구가 궤도면으로부터 약 100mm이내일 때 $100{\mu}m$ 이하 크기의 먼지를 모두 처리할 수 있음을 확인하였다. 이러한 흡입구와 사이클론형식의 프리필터를 탑재한 터널집진차량은 후단에 설치된 전기집진기의 부하를 줄이고, 지하 터널내의 미세먼지와 초미세먼지의 제거에 효과적으로 활용될 수 있을 것으로 기대된다.