• Title/Summary/Keyword: Electric Power and LNG Load

Search Result 7, Processing Time 0.018 seconds

Comparative Evaluation of Electric Power and LNG Load according to Floor level of Tower-Type Apartments (탑상형 아파트의 층별 전기와 가스 부하량 비교평가)

  • Kim, Jun Hyun;Choi, Jin Ho;Um, Jung-Sup
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.4
    • /
    • pp.465-475
    • /
    • 2011
  • It is known that energy consumption in bottom floor of typical Korean-style apartment is the highest. Previous studies for energy consumption in accordance with floor level appear to be very limited due to the dependence on single energy variable such as electric power or LNG separately, based on past flat type of apartment. Acknowledging these constraints, an empirical study for a tower type emerged recently as new style of apartment in South Korea was conducted to demonstrate how a comprehensive evaluation for both electric power and LNG consumption can be used to assist in monitoring the total energy consumption in terms of floor specific settings. It was possible to identify that energy consumption in bottom floor is lesser than that of top floor, to the contrary, fact known from previous study. Also electric power consumption in top floor was identified as 15% higher than that of floor in the least. It is anticipated that this integrated utilization of electric power and LNG data would present more scientific and objective evidence for the energy load among floor level of tower type apartment by overcoming serious constraints suffered from the past single variable investigation. Ultimately, the result in this paper could be used as a valuable reference to providing priority for energy saving activities in top floor such as cool roof or green roof.

Optimization Power Management System for electric propulsion system (전기추진시스템용 OPMS 기법 연구)

  • Lee, Jong-Hak;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.8
    • /
    • pp.923-929
    • /
    • 2019
  • The stability of the propulsion system is crucial for the autonomous vessel. Multiple power generation and propulsion systems should be provided for the stability of the propulsion system. High power generation capacity is calculated for stability, resulting in economical decline due to low load operation. To solve this problem, we need to optimize the power system. In this paper, an OPMS for electric propulsion ship is constructed. The OPMS consists of a hybrid power generation system, an energy storage system, and a control load system. The power generation system consists of a dual fuel engine, the energy storage system is a battery, and the control load system consists of the propulsion load, continuous load, intermittent load, cargo part load and deck machine load. The power system was constructed by modeling the characteristics of each system. For the experiment, a scenario based on ship operation was prepared and the stability and economical efficiency were compared with existing electric propulsion ships.

Battery-loaded power management algorithm of electric propulsion ship based on power load and state learning model (전력 부하와 학습모델 기반의 전기추진선박의 배터리 연동 전력관리 알고리즘)

  • Oh, Ji-hyun;Oh, Jin-seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1202-1208
    • /
    • 2020
  • In line with the current era of the 4th Industrial Revolution, it is necessary to prepare for the future by integrating AI elements in the ship sector. In addition, it is necessary to respond to this in the field of power management for the appearance of autonomous ships. In this study, we propose a battery-linked electric propulsion system (BLEPS) algorithm using machine learning's DNN. For the experiment, we learned the pattern of ship power consumption for each operation mode based on the ship data through LabView and derived the battery status through Python to check the flexibility of the generator and battery interlocking. As a result of the experiment, the low load operation of the generator was reduced through charging and discharging of the battery, and economic efficiency and reliability were confirmed by reducing the fuel consumption of 1% of LNG.

Hybrid Energy Storage System with Emergency Power Function of Standardization Technology (비상전원 기능을 갖는 하이브리드 에너지저장시스템 표준화 기술)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.187-192
    • /
    • 2019
  • Hybrid power storage system with emergency power function for demand management and power outage minimizes the investment cost in the building of buildings and factories requiring emergency power generation facilities, We propose a new business model by developing technology that can secure economical efficiency by reducing power cost at all times. Normally, system power is supplied to load through STS (Static Transfer Switch), and PCS is connected to system in parallel to perform demand management. In order to efficiently operate the electric power through demand forecasting, the EMS issues a charge / discharge command to the ESS as a PMS (Power Management System), and the PMS transmits the command to the PCS controller to operate the system. During the power outage, the STS is rapidly disengaged from the system, and the PCS becomes an independent power supply and can supply constant voltage / constant frequency power to the load side. Therefore, it is possible to secure reliability through verification of actual system linkage and independent operation performance of hybrid ESS, By enabling low-carbon green growth technology to operate in conjunction with an efficient grid, it is possible to improve irregular power quality and contribute to peak load by generating renewable energy through ESS linkage. In addition, the ESS is replacing the frequency follow-up reserve, which is currently under the charge of coal-fired power generation, and thus it is anticipated that the operation cost of the LNG generator with high fuel cost can be reduced.

A Survey on the Co-Generation Load for Large Commercial Buildings (대형상업건물의 열병합발전 부하조사)

  • 한승호;권순우;정상원;정재혁
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.223-230
    • /
    • 1998
  • Energy consumption statistics have been surveyed for 50 large commercial buildings with high energy consumption records in Seoul City. The buildings were classified into three different groups for data analysis: hospitals, hotels, and department stores/office buildings. The analysis was focused on identifying installed boiler and refrigerator data, energy consumption rates, and energy load distribution throughout the year. Refrigerating electricity was confirmed again to affect most on the formation of the summer electricity load peak as expected. Replacing the refrigerator electricity peak in the summer with co-generation in large commercial buildings. However, overall heat load distribution in a single building is still considered not large enough for economically feasible co-generation and thus joint co-generation for multiple neighboring buildings are preferred and the Electric Power Law and LNG pricing policy should be revised favorably for co-generation in advance.

  • PDF

An Experimental Study on the Operation of a Power Generation Engine with Syngas from RPF (폐기물 열분해 합성가스를 이용한 발전용 엔진구동에 대한 실험적 연구)

  • Jeong, Hyo-Jae;Lee, Jeong-Woo;Lee, Jae-Wook;Moon, Ji-Hong;Choi, In-Soo;Park, Sang-Shin;Hwang, Jung-Ho;Yu, Tae-U;Lee, Uen-Do
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.3
    • /
    • pp.48-56
    • /
    • 2010
  • Performances of power generation engine were investigated with syngas from RPF. A stoker type, multi-staged pyrolysis-gasification system, was employed for syngas generation and the syngas was refined with the sequential cleaning processes composed of a gas cooler, a bag filter and a wet scrubber. 20 kWe commercial syngas power generation engine was adopted to burn the cleaned syngas which is mainly composed of hydrogen, carbon monoxide, carbon dioxide and methane. The performance of the engine was tested with various syngas compositions and the results were compared to LNG case. Electric power output, exhaust gas temperature, and emission characteristics were measured, and the efficiency of engine generation was investigated as a function of load of power generation.

A Comparative Study on Power System Harmonics for Offshore Plants (해양플랜트 전력시스템의 고조파 비교분석에 관한 연구)

  • Kim, Deok-Ki;Lee, Won-Ju;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.900-905
    • /
    • 2016
  • The field of power system harmonics has been receiving a great deal of attention recently. This is primarily due to the fact that non-linear (or harmonic-producing) loads comprise an ever-increasing portion of what is handled at a typical industrial plant. The incidence rate of harmonic-related problems is low, but awareness of harmonic issues can still help increase offshore power plant system reliability. On the rare occasion that harmonics become a problem, this is either due to the magnitude of harmonics produced or power system resonance. This harmonic study used an electrical configuration for the offloading scenario of a Floating LNG (FLNG) unit, considering power load. This electrical network configuration is visible in the electrical network load flow study part of the project. This study has been carried out to evaluate the performance of an electric power system, focusing on the harmonic efficiency of an electrically driven motor system to ensure offshore plant safety. In addition, the design part of this study analyzed the electric power system of an FLNG unit to improve the safety of operation and maintenance.