• 제목/요약/키워드: Electric Power Reduction System

검색결과 337건 처리시간 0.026초

배전운영시스템용 응용 프로그램을 위한 공통 데이터베이스 구축 (Development of Common Database for the Application Programs of Distribution Management System)

  • 윤상윤;추철민;권성철;이학주
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1199-1208
    • /
    • 2013
  • In recent years, the development of application programs for distribution system analysis and control has been essential part for distribution management system (DMS). In this paper, we propose the common database for application programs of distribution management system. The proposed database model has several characteristics as followings. First, the proposed database model is designed for the common use of almost the whole distribution application software. The static equipment model and dynamic type tables are mixed and the parallel table structure is applied. Second, the linked list structure of database are used for the fast processing of applications. The database model includes the hierarchy and non-hierarchy distribution system structure. Third, the reduction method of distribution database is applied. For this, we present the network reduction rules. The basic concept of reduction rules are the electrical unification of successive line section which has not lateral branches and the removal of simple lateral branches which has no devices and other laterals. Proposed database model is tested for the Jeju system of Korea Electric Power Corporation (KEPCO). Through the test, we verified that the proposed database structure can be effectively used to accomplish the distribution system operation.

상전원의 피크치 전력 감소를 위한 전력병합장치 회로설계 (Circuit Design of Parallel Power Operation Equipment for Peak Power Reduction)

  • 양재수;김동한;김만도
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제3권9호
    • /
    • pp.273-278
    • /
    • 2014
  • 최근 전력의 수요공급 불균형으로 전력사용 피크시간대의 전력사용 강제 제한이 불가피하다. 따라서, 본 논문에서는, 피크전력이 발생하지 않는 시간대의 전기를 저장하고 전력부족이 예상되는 피크전력 시간대에는 저장전력을 공급하는 병렬운전 기기의 회로를 설계하는데 있다. 이 회로설계를 통하여, PRS의 핵심기능인 상용전원과 인버터 발생전원의 병렬연결 운용으로, 상용전원의 피크치 전력을 조절할 수 있었다. 또한 효율을 높이기 위하여 Transless Power Circuit DC-AC 인버터를 개발하였다. 더 나아가, 가변임피던스 제어를 적용하여 무정전 전원장치의 저장전력을 상용전원과 연계함으로써, 기존의 무정전 전원장치에서 구현을 못하고 있는 저장전력 사용시간을 획기적으로 늘릴 수 있는 기술구현 가능성을 입증하였다.

대규모 AC/DC 전력 시스템 실시간 EMP 시뮬레이션의 부하 분산 연구 (Analysis of Distributed Computational Loads in Large-scale AC/DC Power System using Real-Time EMT Simulation)

  • 박인권;이종후;이장;구현근;권용한
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.159-179
    • /
    • 2022
  • Often a network becomes complex, and multiple entities would get in charge of managing part of the whole network. An example is a utility grid. While the entire grid would go under a single utility company's responsibility, the network is often split into multiple subsections. Subsequently, each subsection would be given as the responsibility area to the corresponding sub-organization in the utility company. The issue of how to make subsystems of adequate size and minimum number of interconnections between subsystems becomes more critical, especially in real-time simulations. Because the computation capability limit of a single computation unit, regardless of whether it is a high-speed conventional CPU core or an FPGA computational engine, it comes with a maximum limit that can be completed within a given amount of execution time. The issue becomes worsened in real time simulation, in which the computation needs to be in precise synchronization with the real-world clock. When the subject of the computation allows for a longer execution time, i.e., a larger time step size, a larger portion of the network can be put on a computation unit. This translates into a larger margin of the difference between the worst and the best. In other words, even though the worst (or the largest) computational burden is orders of magnitude larger than the best (or the smallest) computational burden, all the necessary computation can still be completed within the given amount of time. However, the requirement of real-time makes the margin much smaller. In other words, the difference between the worst and the best should be as small as possible in order to ensure the even distribution of the computational load. Besides, data exchange/communication is essential in parallel computation, affecting the overall performance. However, the exchange of data takes time. Therefore, the corresponding consideration needs to be with the computational load distribution among multiple calculation units. If it turns out in a satisfactory way, such distribution will raise the possibility of completing the necessary computation in a given amount of time, which might come down in the level of microsecond order. This paper presents an effective way to split a given electrical network, according to multiple criteria, for the purpose of distributing the entire computational load into a set of even (or close to even) sized computational loads. Based on the proposed system splitting method, heavy computation burdens of large-scale electrical networks can be distributed to multiple calculation units, such as an RTDS real time simulator, achieving either more efficient usage of the calculation units, a reduction of the necessary size of the simulation time step, or both.

보조 전원을 이용한 12 펄스 다이오드 정류기를 사용하는 추진시스템의 고조파 및 토크 리플 저감 (Harmonic and Torque Ripple Reduction of Electric Propulsion System using 12-Pulse Diode Rectifier by Auxiliary Supply)

  • 김종수;서동환;최재혁
    • 해양환경안전학회지
    • /
    • 제19권1호
    • /
    • pp.66-70
    • /
    • 2013
  • 전기추진선박의 추진시스템에 주로 사용되는 3상 정류기의 입력전류는 다양한 저차 고조파를 포함하고 있다. 이러한 고조파 저감을 위해서 대전력이 필요한 대형 선박에 사용되는 전력변환장치는 12펄스 출력의 정류기가 현재 사용되고 있지만 여전히 $12{\pm}1$차의 고조파가 발생되는 문제점이 있다. 또한, 속도 및 토크 제어기법으로 널리 사용되고 있는 직접토크제어기법의 경우에는 토크 리플이 심하고 전동기의 입력전류는 인버터의 스위칭에 의해 고조파를 크게 포함하고 있다. 본 연구에서는 직접토크제어기법을 이용하는 전기추진시스템의 12펄스 정류기에 보조 전원을 공급하여 고조파를 저감하고 토크 제어성능을 향상시켰으며 실선시스템 환경에서 시뮬레이션을 통해 그 유효성을 입증하였다.

수소액화공정에서 LNG 냉열 적용에 관한 시뮬레이션 연구 (Simulation Study on the Application of LNG Cold Energy for Hydrogen Liquefaction Process)

  • 한단비;변현승;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제31권1호
    • /
    • pp.33-40
    • /
    • 2020
  • As hydrogen utilization becomes more active recently, a large amount of hydrogen should be supplied safely. Among the three supply methods, liquefied hydrogen, which is an optimal method of storage and transportation convenience and high safety, has a low temperature of -253℃, which is complicated by the liquefaction process and consumes a lot of electricity, resulting in high operating costs. In order to reduce the electrical energy required for liquefaction and to raise the efficiency, hydrogen is cooled by using a mixed refrigerant in a precooling step. The electricity required for the precooling process of the mixed refrigerant can be reduced by using the cold energy of LNG. Actually, LNG cold energy is used in refrigeration warehouse and air liquefaction separation process, and a lot of power reduction is achieved. The purpose of this study is to replace the electric power by using LNG cold energy instead of the electric air-cooler to lower the temperature of the hydrogen and refrigerant that are increased due to the compression in the hydrogen liquefaction process. The required energy was obtained by simulating mixed refrigerant (MR) hydrogen liquefaction system with LNG cold heat and electric system. In addition, the power replacement rate of the electric process were obtained with the pressure, the temperature of LNG, the rate of latent heat utilization, and the hydrogen liquefaction capacity, Therefore, optimization of the hydrogen liquefaction system using LNG cold energy was carried out.

이동식 전원공급장치 기반 전기추진차도선의 개념설계 연구 (Conceptual Design for Fully Electrified Car Ferry Powered by Removable Battery System)

  • 이준호;장동원;진송한;신승우
    • 해양환경안전학회지
    • /
    • 제27권6호
    • /
    • pp.856-866
    • /
    • 2021
  • 대기오염물질 감축에 대한 국제적인 인식이 높아짐에 따라 친환경 선박에 대한 수요가 증가하고 있어 각국에서 전기추진선박 개발을 활발하게 수행하고 있다. 현재 전기추진선박에 대해서는 주로 전기추진시스템 및 전동기 연구를 주로 수행하고 있으며, 선박 관점에서 전기추진시스템 및 배터리의 탑재를 고려한 국내 연안 차도선 개념설계 연구는 수행된 바가 없다. 본 연구에서는 배터리 차량 기반의 이동식 전원공급시스템을 주전원으로 하는 순수전기추진차도선의 개념설계 과정에서의 주요 고려사항에 대하여 검토하였다. 100척 이상의 국내 연안차도선의 제원을 분석하여, 요구사항 만족을 위한 선박의 주요제원 선정과 이동식 배터리 차량 탑재를 고려한 비손상, 손상 복원성능 검토를 수행하였고, 개념설계 과정에서 발생하는 문제의 원인분석을 통해 해결방안을 모색하였다.

전동 하이브리드 무인 드론의 동력 계통 최적화 (Power System Optimization for Electric Hybrid Unmanned Drone)

  • 박정환;류희경;이학태
    • 한국항공우주학회지
    • /
    • 제47권4호
    • /
    • pp.300-308
    • /
    • 2019
  • 드론이 농업 및 산업 운송 분야에 이용되기 위해서는 큰 탑재 하중과 긴 운용시간이 필요하다. 현재의 배터리 기술로는 탑재 하중과 체공 시간을 늘리는 데에 한계가 있고, 특히 현장에서 지속적인 운용이 필요할 때에 배터리의 충전 또는 교환이 번거로운 문제가 있다. 본 연구에서는 내연기관과 발전기, 그리고 배터리와 전기모터가 결합된 복합적인 추진기관을 사용하는 드론의 동력시스템을 최적화하는 과정을 제시한다. 운반과 운용의 제약을 고려하여 이륙중량 200kg 급의 기체를 선정하였다. 내연기관과 직접 연결된 2개의 주 로터가 기체 중량의 대부분을 담당하고, 내연기관으로 구동되는 발전기의 전력을 사용하는 4개의 모터가 자세제어를 담당하도록 시스템을 구성하였다. 드론의 에너지 흐름을 파악하여, 기존의 상용품 중 최적의 모터와 프로펠러를 선정하는 기법을 제시하고, 내연기관의 측정 데이터를 이용하여 최적의 운용 점과 기어비를 도출하는 기법을 제시한다.

비절전 가전기기를 위한 에너지 관리 시스템의 뉴로-퍼지 기반 지능형 추론 알고리즘 설계 (Design of Neuro-Fuzzy based Intelligent Inference Algorithm for Energy Management System with Legacy Device)

  • 최인환;유성현;정준호;임묘택;오정준;송문규;안춘기
    • 전기학회논문지
    • /
    • 제64권5호
    • /
    • pp.779-785
    • /
    • 2015
  • Recently, home energy management system (HEMS) for power consumption reduction has been widely used and studied. The HEMS performs electric power consumption control for the indoor electric device connected to the HEMS. However, a traditional HEMS is used for passive control method using some particular power saving devices. Disadvantages with this traditional HEMS is that these power saving devices should be newly installed to build HEMS environment instead of existing home appliances. Therefore, an HEMS, which performs with existing home appliances, is needed to prevent additional expenses due to the purchase of state-of-the-art devices. In this paper, an intelligent inference algorithm for EMS at home for non-power saving electronic equipment, called legacy devices, is proposed. The algorithm is based on the adaptive network fuzzy inference system (ANFIS) and has a subsystem that notifies retraining schedule to the ANFIS to increase the inference performance. This paper discusses the overview and the architecture of the system, especially in terms of the retraining schedule. In addition, the comparison results show that the proposed algorithm is more accurate than the classic ANFIS-based EMS system.

다기능 인버터의 손실저감을 위한 Buck-Type 충전기법 (Buck-Type Charging Method for Loss Reduction of Multi-Function Inverter)

  • 김동희;우동균;이병국
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1523-1528
    • /
    • 2011
  • This paper proposes buck-type charging method using motor inductance, 3-phase inverter and bi-directional converter without an additional charger in plug-in hybrid electric vehicles. The proposed system has advantages over the conventional system such as high charging efficiency, high power factor, and low total harmonic distortion. The validity of each methods are verified by theoretical analysis and simulation.

선박 운전 환경에 따른 하이브리드 전기추진선박의 운전모드별 출력 특성에 관한 연구 (A study on characteristics of each operation mode for hybrid electric propulsion ship by operation circumstances)

  • 김종수;전현민;김덕기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권3호
    • /
    • pp.245-250
    • /
    • 2017
  • 전 세계적으로 온실가스 및 대기 오염물질 배출 저감을 위한 환경 규제가 강화되고 있고, 그에 따라 여러 가지 대책들이 마련되고 있다. 또한 환경오염 최소화와 더불어 효과적이고 합리적인 에너지 절감 방법에 대한 필요성이 점차 커지고 있는 실정이다. 선박 분야의 경우에는 친환경 선박 개발이 활발히 연구되고 있으며 배기가스 배출저감, 대체 연료 개발, 새로운 추진 방식의 선박 등이 이러한 연구 범주에 속한다. 본 논문에서는 하이브리드 전기추진선박에 대한 기본 개념을 제시하고, 선박 운전환경 분석에 따른 하이브리드 전기추진선박의 전력공급 시스템 배터리 단독 운전, 발전기 단독 운전 및 전 출력 운전 모드로 구성하고 각 운전 모드별 속도, 전류, 전압 및 출력 특성을 분석하였다.