• 제목/요약/키워드: Electric Power Loads

검색결과 364건 처리시간 0.018초

Estimation on clamping load of high strength bolts considering various environment conditions

  • Nah, Hwan-Seon;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제24권4호
    • /
    • pp.399-408
    • /
    • 2017
  • Of high strength bolts, the torque shear type bolt is known to be clamped normally when pin-tails are broken. Sometimes the clamping loads on slip critical connections considerably fluctuate from the required tension due to variation of torque coefficient. This is why the viscosity of lubricant affects the torque coefficient by temperature. In this study, the clamping tests of high strength bolts were performed independently at laboratory conditions and at outdoor environment. The temperatures of outdoor environment candidates were ranged from $-11^{\circ}C$ to $34^{\circ}C$ for six years. The temperature at laboratory condition was composed from $-10^{\circ}C$ to $50^{\circ}C$ at each $10^{\circ}C$ interval. At outdoor environment conditions, the clamping load of high strength bolt was varied from 159 to 210 kN and the torque value was varied from 405 to 556 Nm. The torque coefficients at outdoor environment were calculated from 0.126 to 0.158 when tensions were measured from 179 to 192 kN by using tension meter. The torque coefficients at outdoor environment conditions were analyzed as the range from 0.118 to 0.152. From these tests, the diverse equations of torque coefficient, tension dependent to temperature can be acquired by statistic regressive analysis. The variable of torque coefficient at laboratory conditions is 0.13% per each $1^{\circ}C$ when it reaches 2.73% per each $1^{\circ}C$ at outdoor environment conditions. When the results at laboratory conditions and at outdoor environment were combined to get the revised equations, the change in torque coefficient was modified as 0.2% per each $1^{\circ}C$ and the increment of tension was adjusted as 1.89 % per each $1^{\circ}C$.

Energy harvesting from piezoelectric strips attached to systems under random vibrations

  • Trentadue, Francesco;Quaranta, Giuseppe;Maruccio, Claudio;Marano, Giuseppe C.
    • Smart Structures and Systems
    • /
    • 제24권3호
    • /
    • pp.333-343
    • /
    • 2019
  • The possibility of adopting vibration-powered wireless nodes has been largely investigated in the last years. Among the available technologies based on the piezoelectric effect, the most common ones consist of a vibrating beam covered by electroactive layers. Another energy harvesting strategy is based on the use of piezoelectric strips attached to a hosting structure subjected to dynamic loads. The hosting structure, for example, can be the system to be equipped with wireless nodes. Such strategy has received few attentions so far and no analytical studies have been presented yet. Hence, the original contribution of the present paper is concerned with the development of analytical solutions for the electrodynamic analysis and design of piezoelectric polymeric strips attached to relatively large linear elastic structural systems subjected to random vibrations at the base. Specifically, it is assumed that the dynamics of the hosting structure is dominated by the fundamental vibration mode only, and thus it is reduced to a linear elastic single-degree-of-freedom system. On the other hand, the random excitation at the base of the hosting structure is simulated by filtering a white Gaussian noise through a linear second-order filter. The electromechanical force exerted by the polymeric strip is negligible compared with other forces generated by the large hosting structure to which it is attached. By assuming a simplified electrical interface, useful new exact analytical expressions are derived to assess the generated electric power and the integrity of the harvester as well as to facilitate its optimum design.

72.5kV GIS 전력 장비의 KEPCO 기준 내진 및 응력 해석 (Seismic and Stress Analysis of 72.5kV GIS for Technical Specification of KEPCO)

  • 이재환;김영중;김소울;방명석
    • 한국전산구조공학회논문집
    • /
    • 제30권3호
    • /
    • pp.207-214
    • /
    • 2017
  • 국내의 72.5kV 이상, 주파수 60Hz의 송배전설비인 옥내 및 옥외용 가스절연개폐장치(GIS)는 내진 안전성에 대해 국가에서 정한 한전표준규격(ES-6110-0002)을 만족해야 한다. 이 규격에서 명시되지 않은 사항은 IEC 62271-203, 62271-207 등의 관련 기기 규격에 준한다. 한전표준규격에서 기기는 정상사용상태와 특수사용상태에서 건전성이 유지되어야 한다. 안전성 판단을 위해 ASME BPVC SEC.VIII 내압용기 설계 기준에 의해 A6061-T6 재질의 GIS에 대한 정상사용상태 기준과 국내 한전표준규격과 국외 IEC 62271-207에 의한 특수사용상태 기준(지진)에 대한 총체적 응력상태를 판단하였다. 한전표준규격 기준(0.22g) 적용시, 최종응력이 알루미늄인 Part A는 78.2MPa, Part D2의 경우 102.3MPa로, ASME 허용응력 값 181.5MPa를 만족하고 있다. IEC 62271-207 High 0.5g의 경우에도 최종응력은 Part A는 90.5MPa, Part D2는 103.8MPa이다. 본 연구 결과, 72.5kV GIS는 한전표준규격의 구조안전성과 내진성능을 충분히 만족함을 보이고 있다. 내진해석으로 내진시험을 수행할 수 없는 대형 전력기기의 내진성능 실증에 활용될 수 있을 것으로 기대된다.

마이크로그리드용 4-Leg 방식 PCS의 각상 개별제어 알고리즘에 관한 연구 (Single-phase Control Algorithm of 4-Leg type PCS for Micro-grid System)

  • 김승호;최성식;김승종;노대석
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.817-825
    • /
    • 2017
  • AC 방식 마이크로그리드는 다양한 DC/AC 인버터를 AC 네트워크에 연결하여, DC 방식 마이크로그리드의 약점을 극복 하고 있다. 그러나 소규모 마이크로그리드에서 일반적으로 발생하는 심각한 부하 불평형 현상에 의하여, AC 마이크로그리드 시스템의 성능을 약화시킬 수 있다. 이것은 마이크로그리드 내의 불평형 부하로 인하여 상별 에너지 흐름과 전압조정기능이 제한되기 때문이다. 이러한 불평형 전압문제를 해결하기 위하여, 3상 4-Leg 방식의 인버터가 제안되고 있지만, 이를 안정적으로 운용할 수 있는 제어알고리즘이 미비한 실정이다. 따라서, 본 논문에서는 부하 불평형에 의해서 발생하는 인버터의 전압 불평형 문제를 해결하고 안정적으로 제어하기 위하여 d-q제어를 기반으로 3상4선식 인버터의 각상 개별제어 알고리즘을 제안하였다. 또한, 이 알고리즘을 바탕으로 Matlab/Simulink를 이용하여 4-Leg 방식의 전압제어기 모델링을 수행하였다. 이 모델링과 250KW급 시험장치를 바탕으로 인버터의 출력전압 제어특성을 분석한 결과, 정상상태에서는 기존의 방식과 비슷한 특성을 보이지만, 과도상태에서는 제안한 각상 개별제어 방식이 기존의 방식보다 안정적으로 동작하여 제안한 방식의 유용성을 확인할 수 있었다.