• Title/Summary/Keyword: Electric Power Equipment

Search Result 792, Processing Time 0.026 seconds

Development and Verification of Analytical Model of a Pilot Operated Flow Control Valve for 21-ton Electric Excavator (21톤급 전기 굴삭기용 파일럿 작동식 유량제어 밸브의 해석모델 개발 및 검증)

  • Kim, D.M.;Nam, Y.Y.;Seo, J.H.;Jang, J.S.
    • Journal of Drive and Control
    • /
    • v.12 no.3
    • /
    • pp.52-59
    • /
    • 2015
  • An electro hydraulic poppet valve (EHPV) and a variable orifice poppet are assembled in a single block, which is referred to as a RHINO but is also generally called a pilot-operated flow control valve. In this study, we analyzed the structure and the operating principle for a RHINO applied in a 21-ton electric excavator system. The RHINO was experimentally tested to measure the dynamic responses and the pressure energy loss. In this test, we investigated the variation in the conductance coefficient according to the increase in the supply pressure under a constant current and a variation in the flow rate according to the increase in the current. Then, the geometrical shapes and the spring stiffness of the RHINO were considered to develop an analysis model. The characteristics (current-force and hysteresis) for the solenoid based on the experimental data were reflected in the analysis model that was developed, and the reliability of the analysis model was also verified by comparing the experimental and analytical results. The developed model is thus considered to be reliable for use in a wide range of applications, including optimum design, sensitivity analysis, parameter tuning, etc.

A Study of the Development Safety Criteria for Hybrid Electrical Propulsion Fishing Boats (전기복합 추진어선의 안전기준 개발에 관한 연구)

  • Cheol eon Kang;Chul ho Baek;Sung hun Kim;Chan jae Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.207-214
    • /
    • 2023
  • Ships emit significant amounts of air pollution. To reduce ship emissions, the government has implemented the Eco-Friendly Ship Act to improve the marine air environment, under which the use of eco-friendly ships that use eco-friendly energy as a power source encouraged and technologies to reduce marine pollution are developed. Therefore, the revision of relevant laws and systems such as inspection and facility standards for the safe operation of eco-friendly ships is urgently needed, especially those for fishing vessels, which account for the majority of domestic coastal vessels. This study defines the core equipment for the application of electric complex propulsion systems to fishing boats and presents a minimum safety standard plan for the adoption and dissemination of eco-friendly fishing boats.

R&D Trends and Technology Development Plan on Portable Fuel Cell for Future Soldier System (미래병사체계를 위한 휴대형 연료전지 기술개발 동향 및 발전방안)

  • Lee, Yu Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.618-624
    • /
    • 2020
  • A portable power supply system for soldiers must be able to supply electric energy corresponding to the power consumption of combat support troops, and have a carrying load in a range that does not impair the combatant's ability to execute operations. In particular, as the total required power of combat equipment increases with the advances in the future soldier system, a portable, lightweight power supply system with high efficiency is essential. A fuel cell has a high energy-to-weight density compared to lithium batteries, which are used mainly as a military power source system. Therefore, it is capable of miniaturization and lightweight, making active R&D to a portable power supply system. In this paper, the characteristics of the fuel cell applied as a portable power supply system, and the R&D trends of domestic and foreign military portable fuel cell systems were investigated. The current status of domestic technology compared to the level of foreign development was analyzed. In addition, future technology development plans are presented based on the consideration factors when developing a portable fuel cell (power supply stability, portability, and cost reduction) so that it can be used when establishing a plan on the development of a portable fuel cell system for the future soldier system.

Condition Assessment for Wind Turbines with Doubly Fed Induction Generators Based on SCADA Data

  • Sun, Peng;Li, Jian;Wang, Caisheng;Yan, Yonglong
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.689-700
    • /
    • 2017
  • This paper presents an effective approach for wind turbine (WT) condition assessment based on the data collected from wind farm supervisory control and data acquisition (SCADA) system. Three types of assessment indices are determined based on the monitoring parameters obtained from the SCADA system. Neural Networks (NNs) are used to establish prediction models for the assessment indices that are dependent on environmental conditions such as ambient temperature and wind speed. An abnormal level index (ALI) is defined to quantify the abnormal level of the proposed indices. Prediction errors of the prediction models follow a normal distribution. Thus, the ALIs can be calculated based on the probability density function of normal distribution. For other assessment indices, the ALIs are calculated by the nonparametric estimation based cumulative probability density function. A Back-Propagation NN (BPNN) algorithm is used for the overall WT condition assessment. The inputs to the BPNN are the ALIs of the proposed indices. The network structure and the number of nodes in the hidden layer are carefully chosen when the BPNN model is being trained. The condition assessment method has been used for real 1.5 MW WTs with doubly fed induction generators. Results show that the proposed assessment method could effectively predict the change of operating conditions prior to fault occurrences and provide early alarming of the developing faults of WTs.

A Study on the Decision Strategy of Investment Priority Focused on Economics in Distribution Network (경제성에 기반한 배전계통 설비투자 우선순위 결정에 관한 연구)

  • Park, Chang-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.31-39
    • /
    • 2009
  • This paper shows prioritization process for equipment investment plans considering reliability indices and economical efficiency. To decide prioritization of distribution investment projects, we made a distribution system model using system configuration, it's component and load information and designed several investment alternatives to improve reliability of present system. Lastly, we proposed a evaluation model of economical efficiency assessment on distribution investment alternative projects. To analyze influence by reliability and economical efficiency, we produced economical effects with applying time-varying failure rate of KEPCO's main equipments of distribution system and interruption cost of electric power affected by investment. Finally, in order to insure the validity of this proposed methodology, we compared investment prioritization by economical evaluation with that of real investment alternatives of KEPCO's branch office. In conclusion, this paper shows what and how to interpret the reliability effects of distribution system investments into financial indicators beneficial for power utilities's managers to make decision on the perspective of corporate value.

Analysis of New Solar Cell Model for the Virtual Implemented Solar Cell System (가상구현 태양전지 시스템을 위한 태양전지의 새로운 모델링)

  • Jeong, Byung-Hwan;Kang, Byoung-Hee;Lee, Myung-Un;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.79-89
    • /
    • 2006
  • Particularly the photovoltaic systems are preferred because the output is extracted to the useful electric energy. However, the output characteristics of photovoltaic(PV) systems using solar cell or array depend on the weather conditions. The assistant equipment which emulates the solar cell characteristics that can be controlled arbitrarily by researcher is required to the researchers for reliable experimental data. To solve these problems, it is necessary to research a solar cell model of which output characteristics varied by setting the weather conditions such as insolation levels and temperatures. Therefore, this paper was presented that improved model which is based on interpolation model. To verified the improved model, it is confirmed using the simulation of MATLAB. Also, the experiment was performed by the characteristics of virtual implemented solar cell(VISC) system with the proposed solar cell model. It could be confirmed that there exists actual ewer within 5% between actual solar cell and VISC system.

A SCADA Testbed Implementation Architecture for Security Assessment (SCADA 시스템의 보안성 평가를 위한 테스트베드 구성)

  • Lee, Jong-Joo;Kim, Seog-Joo;Kang, Dong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.50-56
    • /
    • 2010
  • Supervisory Control and Data Acquisition Systems (SCADAs) is real-time monitor and control systems. SCADA systems are used to monitor or control chemical and transportation processes, in municipal water supply systems, electric power generation, transmission and distribution, gas and oil pipelines, and other distributed processes. SCADA refers to a large-scale distributed system. The supervisory control system is placed on top of a real time control system to control external processes. Emerging security technologies and security devices are decreasing the vulnerability of the power system against cyber threats. Dealing with these threats and analyzing vulnerabilities is an important task for equipment such as RTU, IED and FEP. To reduce such risks, we develop such a SCADA testbed. This paper presents the development of a testbed designed to assess the vulnerabilities SCADA networks(including serial communication).

Performance Analysis of IEEE 802.15.4 for D1 Small Distribution Substation (D1 소규모 배전 변전소를 위한 IEEE 802.15.4 성능 분석)

  • Hwang, Sung-Ho;Kang, Eun-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.115-121
    • /
    • 2017
  • Times New RomanThe utilization of Information and Communication Technologies (ICT) in the smart grid application can construct efficient and reliable electrical grid. IEC 61850 was adopted as the standard for smart grid exchanging the information required in an electric power utility. However, applying technologies like IEC 61850 using Ethernet to the automation of small distribution substation directly may cost more than the value of the small distribution substation itself. IEEE 802.15.4 technology attracts attention in the field of power utility automation because of low installation cost and ease of installation. Studies are conducted, which use IEEE 802.15.4 in less strict D1 small distribution substation. This study applied IEEE 802.15.4 to the small distribution substation and conducted performance evaluation using the actual equipment. This study determined the scope of application of IEEE 802.15.4 by conducting a comparative analysis of the message type in IEC 61850.

A Ringing Surge Clamper Type Active Auxiliary Edge-Resonant DC Link Snubber-Assisted Three-Phase Soft-Switching Inverter using IGBT-IPM for AC Servo Driver

  • Yoshitsugu, Junji;Yoshida, Masanobu;Hiraki, Eiji;Inoue, Kenji;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.115-124
    • /
    • 2002
  • This paper presents an active auxiliary edge-resonant DC link snubber with a ringing surge damper and a three-phase voltage source type zero voltage soft-switching inverter with the resonat snubber treated here for the AC servo motor driver applications. The operation of the active auxiliary edge-resonant DC link snubber circuit with PWM voltage is described, together with the practical design method to select its circuit parameters. The three-phase voltage source type soft-switching inverter with a single edge-resonant DC link snubber treated here is evaluated and discussed for the small-scale permanent magnet (PM) type-AC servo motor driver from an experimental point of view. In addition to these, the AC motor stator current and its motor speed response for the proposed three-phase soft-switching inverter employing Intelligent Power Module(IPM) based on IGBTS are compared with those of the conventional three-phase hard-switching inverter using IPM. The practical effectiveness of the three-phase soft-switching inverter-fed permanent magnet type AC motor speed tracking servo driver is proven on the basis of the common mode current in a novel type three-phase soft-switching inverter-fed AC motor side and the conductive noise on the mains terminal interface voltage as compared with those of the conventional three-phase hard-switching inverter-fed permanent magnet type AC servo motor driver for the speed tracking applications.

Analysis on Momentary Voltage Dips with the Interconnection Operation of Utility-interactive Cogneration Systems Considering Their Generator Type (발전기 형태를 고려한 열병합발전시스템의 배전계통 연계운전시의 순시전압변동 해석)

  • 최준호;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.23-30
    • /
    • 2000
  • Cogeneration systems are seen as a significant innovation for dispersed energy generation since they are both environmentally friendly and has comparatively high degrees of efficiency. It is especially suited for the decentralized provision of electricity and heat. However, it causes operational problems such as voltage regulation, voltage variation, protection and safety. Especially, it is expected that the interconnection/disconnection operation of cogeneration system has an effect on distribution voltage regulation and variation. Recently, with the increased use of customer-owned computers and other sensitive electronic equipment, electric power quality has become an important concerns. Therefore, the voltage quality problems with cogeneration system should be investigated because the voltage quality is an important part of electrical power quality. In this paper, the momentary voltage dips associated with the interconnection/disconnection operation of cogeneration system are analyzed, including restraint solutions at the customer level. In addition, the unit capacity of cogeneration systems per feeder are evaluated from the view point of momentary voltage variations. The results of this paper are useful analysis data for interconnection standards/guidelines of cogeneration systems and dispersed generation (DG)

  • PDF