• 제목/요약/키워드: Electric Line

검색결과 1,916건 처리시간 0.03초

전력선 반송통신을 이용한 전기기기 전원 제어 시스템에 관한 연구 (A Study on the Power Control System for Electric Machineries using Power Line Communication)

  • 김경엽;문복산;유영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권4호
    • /
    • pp.889-897
    • /
    • 2001
  • Recently, a lot of studies on the power line communication(PLC) are being done by many companies and institutes due to its own merit which can use the power line spread widely as a communication channel. But, there are many serious problems about the harsh and unpredictable characteristics, or noise, signal distortion and attenuation to be overcome for commercialization. In this paper, the power line characteristics as the view point of communication channel are investigated and the technologies of PLC are proposed to control the power of electric machineries by using the combined method of ASK modulation and microprocessor technologies. Also experiments are carried out to ascertain performance in case of applying to electric lights control according to various distancea as an example.

  • PDF

154kV 송전선로 피뢰기 설치용 아킹혼 개발 (Development of Arc-horn to be mounted on 154kV Transmission Line Arrester)

  • 민병욱;김우겸;이북창;최한열;박재웅;금의연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.335-336
    • /
    • 2008
  • Overhead transmission lines are mainly crossing mountainous area. They are easily affected in weathers like typhoon, strong wind, lightning, heavy rain, or heavy snow. Sometimes these weathers cause transmission line faults. A lightning flashover is most often fault. Nowadays lightning density in KOREA is growing high and lightning flashovers occur more often. A lightning flashover on transmission line is mostly cleared by momentary operation of a circuit breaker, so power failure happens rarely. However, when both circuits trip simultaneously due to the lightning flashovers on double circuit transmission line, short time power failure and voltage drop happen. KEPCO has used transmission line arresters to avoid double circuit simultaneous trip out since 2003. And transmission line arresters cannot be installed with KEPCO's present metal fittings, so various fittings have been used for each transmission line arrester manufacturer. This paper introduces development and standardization of arc-horn and metal fittings for transmission line arrester which can be used for both existing lines and new lines in KEPCO.

  • PDF

전력구 터널 내 전력선 발열 시 환기방식에 따른 온도분포에 대한 전산해석 (Numerical Simulation on the Temperature Distribution by Ventilation Type during Heat of the Power line in Electric Power Tunnel)

  • 이호형;이승철;곽동걸;백두산
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.3-4
    • /
    • 2014
  • Power line in electric power tunnel generate heat around during power transmission. Rising temperature inside the electric power tunnel reduces the transmission efficiency of the power line. In this study, trying to understand the change in temperature in the electric power tunnel by forced ventilation and natural ventilation when the temperature rise of the electric power tunnel. The results show that average temperature in electric power tunnel by natural ventilation, forced ventilation is $56.55^{\circ}C$, $23.25^{\circ}C$. Therefore electric power tunnel during power transmission needs cooling or ventilation system.

  • PDF

Prediction of ions migration behavior in mortar under 2-D ALMT application to inhibit ASR

  • Liu, Chih-Chien;Kuo, Wen-Ten
    • Computers and Concrete
    • /
    • 제14권3호
    • /
    • pp.263-277
    • /
    • 2014
  • This study investigated four electric field configurations of two-dimensional accelerate lithium migration technique (ALMT), including line-to-line, plane-to-line, contour-to-line and plane-to-plane, and analyzed the ion migration behavior and efficiency. It was found that the free ion distribution diagram and voltage distribution diagram were similar, and ions migrated in the power line direction. The electrode modules were used for the mortar specimen with w/c ratio of 0.5. The effectively processed areas accounted for 14.1%, 39.0%, 49.4% and 51.4% of total area respectively on Day 28. Larger electrode area was more advantageous to ion migration. In addition, it was proved that the two-dimensional electric field could be divided into different equifield line active regions, and regarded as affected by one-dimensional electric field, and the ion migration results in various equifield line active regions were predicted by using the duration analysis method based on the theoretical model of ion migration obtained from one-dimensional test.

전력선 반송통신을 이용한 전기기기 전원 제어 시스템에 관한 연구 (A Study on the Power Line Control System for Electric Machinery using Power Line Communication)

  • 김경엽;문복산;김영일;서인호;천행춘;강대기;유영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 추계학술대회 논문집(Proceeding of the KOSME 2000 Autumn Annual Meeting)
    • /
    • pp.115-122
    • /
    • 2000
  • Recently, a study on the Power Line Communication has been done by many companies and institutes due to its own merits that we can use the power line as a communication channel. But, there are serious problems about the harsh and unpredictable characteristics - noise, signal distortion and attenuation to be overcome in order that we commercialize the Power Line Communication. In this paper, we analyse the power line characteristics and apply the technology of PLC to control power of electric machinery by using ASK modulation.

  • PDF

방전신호 검출에 의한 전기화재 예측 (Electric Fire Prediction by Detection of Discharge Signal)

  • 길경석;송재용;권장우
    • 한국정보통신학회논문지
    • /
    • 제8권2호
    • /
    • pp.413-419
    • /
    • 2004
  • 본 논문은 전기설비로부터 방전신호 검출을 통한 전기화재 예측 기법에 관하여 기술하였다. 방전현상으로부터 전기화재 예측에 필요한 전기적 정보를 얻기 위하여 절연지를 통한 연면 방전, 선간 단락 등 다양한 방전현상을 실험적으로 모의하였다. 실험결과로부터 전기화재 발생시 전원주파수와는 다른 특징적인 주파수 신호가 대부분 차지하는 것을 알 수 있었다. 최종적으로 실험결과에 근거한 방전신호 검출장치를 설계ㆍ제작하였으며, 전원선에서 방전신호를 모니터링하는 것으로 전기화재의 예측이 가능함을 확인하였다.

국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사 (A survey on the EMF Levels of Study and Electric Appliances in Korea)

  • 장성기;조용성;이석조;유승화;정경미;임준호
    • 한국산업보건학회지
    • /
    • 제15권1호
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.

Single Line-to-ground Fault Location and Information Modeling Based on the Interaction between Intelligent Distribution Equipment

  • Wang, Lei;Luo, Wei;Weng, Liangjie;Hu, Yongbo;Li, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1807-1813
    • /
    • 2018
  • In this paper, the fault line selection and location problems of single line-to-ground (SLG) fault in distribution network are addressed. Firstly, the adaptive filtering property for empirical mode decomposition is formulated. Then in view of the different characteristics showed by the intrinsic mode functions(IMF) under different fault inception angles obtained by empirical mode decomposition, the sign of peak value about the low-frequency IMF and the capacitance transient energy is chosen as the fault line selection criteria according to the different proportion occupied by the low-frequency components. Finally, the fault location is determined based upon the comparison result with adjacent fault passage indicators' (FPI) waveform on the strength of the interaction between the distribution terminal unit(DTU) and the FPI. Moreover, the logic nodes regarding to fault line selection and location are newly expanded according to IEC61850, which also provides reference to acquaint the DTU or FPI's function and monitoring. The simulation results validate the effectiveness of the proposed fault line selection and location methods.

Vacuum Interrupter 내부 End_shield가 전계분포에 미치는 영향 (The influence that cup-type shield inner vacuum interrupter causes to electric field distribution)

  • 윤재훈;김병철;허준;임기조;강성화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.478-479
    • /
    • 2008
  • this paper describes the electric field distribution interpretation along a shield form inner vacuum interrupter(VI). The equipotential line and electric field and field vector in a VI are analysed by a finite element method at various shield form. in result, The equipotential line and electric field distribution was affected to VI shield form. The reason is as it gets distortion of equipotential line done. shield of cup type is how to electric field distribution, finally, this paper recognized whether or not affected, and proposed gap with the most suitable shield length and an external insulation.

  • PDF

호남선 EL8100 전기기관차시험 운행에 따른 급전시스템 전력품질 특성 검토 (Analysis of Power Quality in the Substation of Honam Electrification Line according to Running Characteristic of Electric Locomotive)

  • 신창기;한문섭;이장무;장동욱;이한민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1292-1296
    • /
    • 2004
  • This study is experimented results of running characteristics about electric locomotive. it executed to study a power quality in the substation of Honam electrification line and to promote knowledge, observation and management in electric rail-system. we measured to know the more exactly running characteristics that electric locomotive and electric substation at the same time.

  • PDF