• 제목/요약/키워드: Electric Fan

검색결과 181건 처리시간 0.022초

선풍기의 운전 상황별 발열특성 및 전류신호 검출 (Detection of Current Signal and Thermal Characteristics of Electric Fan Operated in Various Situations)

  • 김두현;이흥수
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.20-27
    • /
    • 2014
  • Cooling equipment is the frequent occurrence of fire despite the absence of the heating element. National fire statistics in 2013 show that a total of 263 fires occurred in the cooling equipment and the number of electric fan has 145 fire cases. This is accounted for 55.1% of the whole. Electric fan is the electrical appliance that the heat is generated on the winding wire and the iron core. If such characteristic is not controled properly, fire would break out at the electric fan. also there is a gap filled with an insulator between connection terminals of the capacitor in the electric fan. But in case that the gap on the capacitor is covered with some conductive material such as dust, there would be a fire as well caused by electrical heating locally. Although many studies related with those have been conducted, electric fan fire is continuously occurred. In this study, thermal characteristics and current signal in various conditions such as the heat generation of windings including iron cores of the motor and the dielectric breakdown of terminals on the capacitor connected to the motor were detected. In order to measure the maximum temperature, "third level" wind velocity button was pushed and the time selection switch to "continuation" was set. Analyzed data would be available for the fire safety of the electric fan.

냉각팬 전동화에 따른 시내버스 연비효과 예측 (Prediction of the Effect of Cooling Fan Electrification on City Bus)

  • 이용규;박진일;이종화
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.908-912
    • /
    • 2013
  • Because of their longer operating times and larger size relative to conventional fans, the cooling fans mounted in buses consume larger amounts of energy. Most of the cooling fans mounted in a bus are connected to the engine by a viscous clutch. A viscous cooling fan's speed is determined by its fluid temperature, which is affected by the air flow through the radiator. The fan does not react immediately to the coolant temperature and in doing so causes unnecessary energy consumption. Therefore, the fuel economy of buses using viscous fans can be improved by changing to an electric cooling fan design, which can be actively controlled. In addition, electric power consumption is increased by using electric cooling fans. Thus, when electric fans are applied in conjunction with the alternator management system (AMS), the fuel economy is further enhanced. In this study, simulations were performed to predict coolant temperature and cooling fan speeds. Simulations were performed for both viscous and electric cooling fans, and power consumption was calculated. Additionally, fuel economy was calculated applying both the alternator management system and the electric cooling fan.

선풍기의 날개 수에 따른 공기 유동해석 (Analysis of the Sir Flow due to the Number of Electric Fan Blades)

  • 조재웅;한문식
    • 한국기계가공학회지
    • /
    • 제11권1호
    • /
    • pp.107-112
    • /
    • 2012
  • Air flow and its pressure at electric fan according to three, four and five blades are analyzed in this study. As the number of blades increases at the same condition of specification, air tends to converge and becomes natural wind but higher power is consumed. And the velocity of wind is decreased as the space between winds becomes narrow. The turbulent flow is happened in the center of the body of revolution and the kinetic energy becomes largest in case of three blades. The pressure is decreased than atmospheric pressure from fan to outlet. As the number of blades increases, the pressure drop becomes smaller and is smallest in case of the fan with three blades. As the study result, The electric fan with three blades is thought to be effective in view of power consumption and design.

에너지 전환 이상기능 기반 다구찌 동특성을 활용한 Fan Case 설계 (Fan Case Design using Energy Conversion Ideal Function Based Taguchi Dynamic Characteristics)

  • 지수윤;장중순
    • 대한산업공학회지
    • /
    • 제41권1호
    • /
    • pp.97-104
    • /
    • 2015
  • An electric-motor which uses electric energy to dry laundry in a dryer generates wind by rotating a fan. The roles of electric motor and fan are crucial for drying. To reduce the noises or vibration, their performances should be improved. However, it requires a relatively high cost to redesign them. In this case, redesigning the fan case rather than the motor or the fan would be easier and cheaper. This paper is to apply Taguchi dynamic characteristic concept with the ideal function of energy conversion to redesign the fan case. Not only the increase of the wind power but also the decrease of noise, vibration and the other side effects are resulted.

에너지 절약형 전기 온풍기 개발 (Development of Energy Saving Electric Fan Heater)

  • 김진봉;구대현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.97-99
    • /
    • 1994
  • Energy saving electric fan heater that uses driving part as heating part is different from general fan heater. As it uses energy that drives rotor and generate heat at the same coil. it is simpler and cheaper than fan heater. In this study, shaded-pole motor that is low cost and simple in spite of low efficiency was used for th fan heater.

  • PDF

헤어드라이기의 팬 형상에 따른 열변형에 관한 연구 (A Study on Thermal Deformation due to Fan Shape of Hair Dryer)

  • 한문식;조재웅
    • 한국기계가공학회지
    • /
    • 제16권3호
    • /
    • pp.82-87
    • /
    • 2017
  • This study investigates thermal deformation due to fan shape of a hair dryer. In this study, thermal analysis showed that the shape of an electric fan results in lower temperature than that of a sieve frame. Among the shapes of electric fans, the temperature change decreases as the number of wings decreases. As a result of thermal deformation, model 4 (sieve frame shape) showed increased change of deformation compared to models 1, 2, and 3 (with electric fan shapes). Thus, the model 1 dryer with the sieve frame shape is shown to have the least durability among models 1, 2, 3, and 4. It is thought that the analysis results of this study can be applied to durability improvement and safer design of hair dryers.

3단 스피드 선풍기 모터의 정상 및 고정 운전에 대한 전압, 전류 및 온도 신호 분석 (Analysis on the Voltage, Current and Temperature Signals for Free and Locked Operation of Three Speed Electric Fan)

  • 김윤복;김두현
    • 한국화재소방학회논문지
    • /
    • 제28권3호
    • /
    • pp.87-91
    • /
    • 2014
  • 본 논문은 선풍기 모터의 회전을 정상 및 고정상태로 구분하여 주권선에서의 전압 및 전류, 모터 전체의 온도특성을 분석하여 전기화재 위험성을 제시하는 것을 목표로 하고 있다. 전압과 전류 신호에 대하여, 전압의 경우 정상상태와 고정상태에 대하여 큰 차이점은 없었으며, 전류의 경우는 비정상상태(최대 203 mA)보다 정상상태(최대 309 mA)가 상당히 높았다. 온도신호의 경우, 모터 전반에 있어서 온도 분포도가 다르게 나타났으며, 정상상태의 경우는 $4^{\circ}C$, 고정상태는 $18^{\circ}C$ 차를 보였다. 특히 대부분의 선풍기의 전기배선이 모터의 고정자철심에 부착되어 있었으며 해당전선의 허용온도가 $60^{\circ}C$를 감안했을 때에 절연열화가 가속될 수 있다. 또한 본 데이터는 선풍기 안전장치개발의 기초자료나 전기화재에 대한 조사 자료로 활용할 수 있다.

유입부 형상이 저전압 전동기 냉각홴의 공력성능에 미치는 영향 (Effects of Inlet Vent Shape on Aerodynamic Performance of a Low-Voltage Electric Motor Cooling Fan)

  • 박재민;허만웅;김광용
    • 한국유체기계학회 논문집
    • /
    • 제19권5호
    • /
    • pp.42-49
    • /
    • 2016
  • Aerodynamic analysis of a low-voltage electric motor has been performed with various inlet vent shapes. Effects of inlet vent shape on aerodynamic performance of a motor cooling fan have been investigated numerically using three-dimensional Reynolds-averaged Navier-Stokes equations. The k-${\varepsilon}$ turbulence model was used for the analysis of turbulence. The finite volume method and unstructured tetrahedral grids were used in the numerical analysis. Optimal grid system in the computational domain was selected through a grid-dependency test. From the results of the flow analysis, considerable energy loss by flow separation was observed in the flow passage. It was found that mass flow rate through the cooling fan in the low-voltage motor can be increased by modifying the inlet vent shape. And, some inlet vent shapes were suggested to improve the aerodynamic performance of the motor cooling fan.

Design and Implementation of Continuous Control for Household Electric Fan Speed for Virtual Reality Applications

  • Jonas John, Claud;Dae-Young, Na;Daseong, Han
    • International Journal of Advanced Culture Technology
    • /
    • 제10권4호
    • /
    • pp.518-528
    • /
    • 2022
  • Virtual Reality (VR) has been widely used in various applications to generate realistic virtual environments. A sense of immersion can be increased by providing additional stimuli such as tactile sensation to VR contents. However, it is still challenging to provide a realistic feel for the wind blowing over the whole body by smoothly controlling the airflow. To address this issue, we employ a household electric fan as a wind generating device to provide users with wind experience in VR environments. The wind generating device targets the whole body to mimic the wind we feel outside in our daily life. To do so, we present a low-cost method to smoothly control household fan speed using an Arduino microcontroller. Here, we use the Sinusoidal Pulse Width Modulation (SPWM) technique to generate the sinusoidal voltage required to drive the fan motor. Our experimental results show how Variable Voltage Variable Frequency (VVVF) is implemented at a low cost using our method for household fan speed control. The results can be applied to various VR applications to enhance the sense of immersion by providing users with realistic wind.

제조 사업장의 환풍기 화재위험성 조사 (The Survey of Fire Hazard of Fan in Manufacturing Industries)

  • 김성삼
    • 조명전기설비학회논문지
    • /
    • 제27권10호
    • /
    • pp.21-29
    • /
    • 2013
  • The short circuit and overload is presented by main cause of electrical fire. However, 85% of the fan directly connected the outlet box without switch in total 110 fans as a research in manufacturing industries. In installation direction of vertical type fans which was placed on the horizontal surface, only 39 vertical type fans were placed on vertical surface and 71 fans were placed on the horizontal type. The installation direction of the fans warns of the risk of the fire hazard due to the motor stall to the user manual of the maker. However, it is the representative nonconformity example of construction which the people or builder disregards. In addition, the condition of ground connection with the earth leakage prevention was investigated in grounding of 5 fans, non-grounding of 105 fans. The double insulation structure is generally used for small fan and it can't connect ground wire as electric plug of non-grounding type. However, industrial iron fan needs ground wire for electric leakage and to protect against electric shock.