• 제목/요약/키워드: Electric Equipment Capacity

검색결과 106건 처리시간 0.028초

회귀분석이론을 이용한 지하철 역사의 조명부하밀도 분석 (Recommended Practice for Lighting Load Density by Feature Parameters and Regression Analysis depending on Power Consumption Characteristics in Subway Stations)

  • 정현기;김세동
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.254-259
    • /
    • 2006
  • It is increased electrical energy consumption with the development of intelligence society in the subway station and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design load density in subway stations, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 34 subway stations and 10 electrical design offices. In this dissertation, it is necessary to analyse the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, maximum and thus it was carried linear and nonlinear regression analysis.

  • PDF

대전지역 공동주택의 전력소비 실태 및 패턴 분석 연구 (An Analysis of Electricity Consumption Profile based on Measurement Data in Apartment Complex in Daejeon)

  • 김강식;임경업;윤종호;신우철
    • KIEAE Journal
    • /
    • 제11권5호
    • /
    • pp.91-96
    • /
    • 2011
  • This study is to analysis the characteristics of electric power consumption of apartments complex in Korea. This study shows the pattern of electric power consumption and correlation of each apartment complex's completion year monthly and timely. With this result, we are able to predict the demand pattern of electricity in a house and make the schedule by demand pattern. It is expected this data is used as reference of electric consumption of Daejeon area to operate the simulation tools to predict the building energy. The yearly data of 10 apartment complexes of 2010 are analyzed. The results of this study are followed. The averaged amount of electricity consumption in winter is higher as summer because of the high capacity of heating equipment. All of the house has electric base load from 0.26kWh to 0.5kWh. The average of the electricity consumption of month is shown as 310.2kWh. A week is seperated, as 4 part such as week, weekend, Saturday and Sunday. During week, the average of timely electricity consumption is shown as 0.426kWh. The Saturday consumption is 0.437kWh. The Sunday is 0.445kWh. The peak electricity consumption in summer and winter is measured. The peak consumption on summer season is 1.389kW on 22th August 64% higher than winter season 0.887kW on 3rd January.

MIMO 프리코딩을 고려한 셀 탐색 기법 (A Cell Selection Technique Considering MIMO Precoding)

  • 김한성;홍태환;조용수
    • 한국통신학회논문지
    • /
    • 제37A권12호
    • /
    • pp.1076-1084
    • /
    • 2012
  • CS/CB(Coordinated Scheduling/Beamforming) 방식은 인접 기지국으로부터의 간섭신호를 최소화시키는 MIMO(Multiple Input Multiple Output) 프리코더를 선택함으로써 셀 경계 사용자의 수율을 증가시킨다. 그러나 현재의 LTE(Long Term Evolution) 시스템에서는 안테나 한 개를 사용하여 주위 기지국으로부터 전송된 동기신호와 기준신호를 사용하여 초기화 단계에서 서빙 셀이 선택된다. 이와 같이 선택된 셀은 초기화 단계에서 MIMO 프리코더 이득을 고려하지 않고 선택되었기 때문에 데이터 전송시 최적의 선택이 아닐 수 있다. 본 논문에서는 MIMO 프리코더를 갖는 LTE 시스템을 위하여 초기화 단계에서 프리코더의 영향을 고려하여 셀을 선택하는 기법을 제안한다. 제안된 기법은 후보 기지국들에서 전송한 기준신호를 사용하여 획득한 정보(랭크, 유효 채널 용량, 유효 SINR(Signal to Interference plus Noise Ratio))를 사용하여 셀 경계의 단말이 서빙 기지국을 선택할 수 있도록 한다. 제안한 기법은 기존의 기법과 비교하여 다중 셀 환경하의 LTE 시스템에서 채널 용량을 크게 향상시킬 수 있음을 모의실험을 통하여 확인한다.

화재피해 감소 위한 자동소화장치 적용범위 개선 (Improvement to the Applicable Scope of Automatic Fire Extinguisher to Reduce Fire Damage)

  • 백창선;박인선
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.62-65
    • /
    • 2018
  • The rapid progress toward the 4th industrial society has led to possibilities of fire increase. It is pointed out that, though initial fire suppression is emphasized, the current legal systems do not sufficiently recognize the importance of initial fire suppression. In order to resolve this, problems of the current legal systems and regulations, as well as fire-fighting facilities to be equipped according to the size of specific fire-fighting objects, were diagnosed. Also, suggestions for improvement were provided through comparative analysis with relevant laws and technical regulations of Korea and other countries. According to fire safety standards such as NFPA, IMO, ISO, and Russian standards, automatic fire extinguishers are to be installed as per the adaptability criteria of fire extinguishers and automatic fire extinguishers. In Korea, the "Act on Fire Prevention and Installation, Maintenance, and Safety Control of Fire-fighting Systems" cover the types and scope of fire fighting facilities that include specific fire protection objects, such as electric room, power room, and substation room. This study has identified that, in case of a place with a floor area of less than $300m^2$, the installation requirement is not clearly specified. Therefore, in this study, fire extinguishing equipment and automatic fire extinguishing equipment to be added for each sub-use application are proved to have fire extinguishing performance of Class A, Class B, and Class C, respectively. In view of the fact that, in overseas standards, all space except containing such materials as Deep fire, metal fire and peroxide, can be installed with fire fighting equipment, a legal system for specifying the capacity units of fire fighting apparatus by application is, in this study, proposed.

Remediation of cesium-contaminated fine soil using electrokinetic method

  • Kim, Ilgook;Kim, June-Hyun;Kim, Sung-Man;Park, Chan Woo;Yang, Hee-Man;Yoon, In-Ho
    • Membrane and Water Treatment
    • /
    • 제11권3호
    • /
    • pp.189-193
    • /
    • 2020
  • In this study, electrokinetic remediation equipment was used to remove cesium (Cs) from clay soil and waste solution was treated with sorption process. The influence of electrokinetic process on the removal of Cs was evaluated under the condition of applied electric voltage of 15.0-20.0 V. In addition to monitoring the Cs removal, electrical current and temperature of the electrolyte during experiment were investigated. The removal efficiency of Cs from soil by electrokinetic method was more than 90%. After electrokinetic remediation, Cs was selectively separated from soil waste solution using sorbents. Various adsorption agents such as potassium nickel hexacyanoferrate (KNiHCF), Prussian blue, sodium tetraphenylborate (NaTPB), and zeolite were compared and KNiHCF showed the highest Cs removal efficiency. The Cs adsorption on KNiHCF reached equilibrium in 30 min. The maximum adsorption capacity was 120.4 mg/g at 0.1 g/L of adsorbent dosage. These results demonstrated that our proposed process combined electrokinetic remediation of soil and waste solution treatment with metal ferrocyanide can be a promising technique to decontaminate Cs-contaminated fine soil.

배전계통연계 분산전원의 위상변화에 따른 고립운전 파라미터 특성 (A Study on Islandig Characteristics using Phase Angle Adjustment of Distributed Generation)

  • 방지윤;김학만;이복구;심재선;신명재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.525-526
    • /
    • 2006
  • Recently, much research has been done and many improvements have been developed for islanding protection of distributed generation(DG). Anti-islanding protection for DG must be act very quickly to prevent equipment damage at the time of disconnection and for the safety of maintenance and repair personnel. DG-based detection methods have included both passive and active types, and now research has shifted towards new anti-islanding detection methods that make up for the defects of the previous types. Because differences occur between the utility grid and the DG when connecting and disconnecting depending on the phase difference, voltage, current, relative capacity of electric power, and system operation characteristics, voltage phase angle is an important consideration. In this paper, we simulated islanded operation characteristics comparing phase difference of DG and the connected utility grid, and analyzed various parameters (real power, reactive power, RMS voltage, RMS current, power factor angle, and frequency) by varying the DG's voltage phase angle. Using this information, we propose a suitable DG voltage phase angle for enhanced passive islanding detection techniques.

  • PDF

건물용 열병합발전 시스템의 적정규모 산정을 위한 최적 투자모형 (Optimal Sizing Evaluation Model of Building Cogeneration System)

  • 박종성;원선재;김정훈;박승호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.117-119
    • /
    • 1995
  • For an effective application of the cogeneration system for commercial and industrial buildings, we need to develop a relevant model to determine the long-term based optimal sizing of the cogeneration system considering electrical and thermal load demands, buy and sell contracts with electric utility and the annual production cost. In assessing the optimal sizing of cogeneration, we have to consider both economic parameters and their capacity expansion for the increased electrical and thermals demand in the future. In this paper, we propose a mathematical model for the optimal sizing of cogeneration systems considering annual production costs and other economic parameter such as, lifetime of the equipment, time value of the capital, etc. In the case study, we thoroughly examine the effects of the economic parameters and determine the optimal size of the sample system. In addition, we calculate the payback period of the cogeneration investment.

  • PDF

센서를 이용한 전기장치 측정에 관한 연구 (A Study on electirc equipment measurement using sensors)

  • 한영재;김기환;박춘수;최종선;김정수
    • 센서학회지
    • /
    • 제12권4호
    • /
    • pp.164-169
    • /
    • 2003
  • 최근에 남북철도나 대륙횡단열차 등에 대한 사업성 타당조사가 이뤄지면서 철도차량에 대한 관심이 높아지고 있다. 타교통수단과 비교하여 철도차량은 환경친화적, 정시성, 신뢰성, 그리고 안전성의 특성이 있다. 우리는 한국형 고속철도차량을 평가하기 위한 하드웨어와 소프트웨어를 제작하였다. 소프트웨어는 측정된 데이터를 분석할 수 있도록 해준다. 이 논문에서는 센서를 사용한 철도차량 전기장치 측정에 관해서 연구하였다. 이 시험을 하기 위해서 신호변환시스템을 개발하였다. 이 계측시스템을 이용해서 가선전압, battery전압, 차축속도 등에 관한 중요한 시험결과를 얻을 수 있었다.

고 분해능 레이저 도플러 진동계의 개발 (Development of High Resolution Laser Doppler Vibrometer)

  • 김성훈;고진환;김호성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권2호
    • /
    • pp.125-131
    • /
    • 2000
  • A high resolution Laser Doppler Vibrometer(LDV) developed using electronic fringe counting method. The fringe pattern signal obtained via analog signal processing is divided into two. One was converted to a TTL signal with a ZCD(zero-crossing detector) and then counted to calculate the displacement due to the vibration. The other was directed to the A/D converter to get a high resolution of about $\lambda/320$ with the phase comparison method. The data obtained with the A/D converter was used in the displacement calculation and the result was displayed on a LCD pane. In this study, a Laser Doppler Vibrometer with measurement range of $0.32\mum~129\mum$ and displacement resolution of 2nm, about $\lambda/320$ , was developed. And this LDV can be used to measure the dynamic of microsize devices such as MEMS(Micro Electro-Mechanical Systems) and to diagnose high capacity electric equipment such as circuit breakers and transformers, of which resonant frequencies are changed when they are damaged.

  • PDF

The Estimation of the Dielectric Strength Decrease of the Solid-solid Interfaces by using the Applied Voltage to Breakdown Time Characteristics

  • Shin, Cheol-Gi;Bae, Duck-Kweon
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권6호
    • /
    • pp.278-282
    • /
    • 2007
  • In the complex insulation system that is used in extra high voltage(EHV) devices, according to the trend for electric power equipment of high capacity and reduction of its size, macro interfaces between two different bulk materials which affect the stability of insulation system exist inevitably. In this paper, the dielectric strength decrease of the macro interfaces between epoxy and ethylene propylene diene terpolymer(EPDM) was estimated by using the applied voltage to breakdown time characteristics. Firstly, the AC short time dielectric strength of specimens was measured at room temperature. Then, the breakdown time was measured under the applied constant voltage which is 70% of short time breakdown voltage. With these processes, the life exponent n was determined by inverse power law, and the long time breakdown voltage can be evaluated. The best condition of the interface was LOS(low viscosity(350 cSt) silicone oil spread specimen). When 30 years last on the specimens, the breakdown voltage was estimated 44% of the short time breakdown voltage.