• Title/Summary/Keyword: Electric Energy Management System

Search Result 318, Processing Time 0.026 seconds

Economic Assessment of the Battery Energy Storage System with Its Customer Type (수용가 형태에 따른 전지전력저장시스템의 경제성 평가)

  • 손학식;최준호;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.81-89
    • /
    • 2002
  • The Battery Energy Storage System (BESS) has lots of advantages such as load leveling, quick response emergency power (spinning reserve), frequency and voltage control, improvement of reliability, and deferred generation and transmission construction. However, it is very critical that economic feasibility requires justification from the customer side of meter to promoting the dissemination of BESS in nation widely. In this paper, we proposed the economic assessment model of customer owned BESS which is complemented and improved the existing model. The proposed model is applied to the typical customer types, i.e. light industrial, commercial, and residential, which are taken from the statistical analysis on the load profile survey of Korea Electric Power COmpany (KEPCO). The economic viability performed for each customer load type to justifying their economic feasibility of BESS installation from the economic measures such as payback period, Net Present Worth (NPW), Rate Of Return (ROR). The results show that the BESS has economic benefits to the specific customer type, i.e. residential customer. Therefore, the government and the energy agency should be committing the support program, such as tax incentive, financial support, to disseminate the BESS nation widely. The results of this paper are useful to the customer investment decision-making and the national energy policy & strategy in Korea.

The Design and Implementation of AMI System Using Binary CDMA (Binary CDMA 기반의 AMI 시스템 설계 및 구현)

  • Joe, In-Whee;Jeong, Jong-Yuel
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.8C
    • /
    • pp.663-669
    • /
    • 2012
  • To solve the energy problem and finding new growth engines, interest for the smart grid is increasing and related technologies are making great efforts to secure in the world. AMI (Advanced Metering Infrastructure) Among them is the first to be constructed and getting attention as a key component of smart grid. A fusion of various technologies in technology development and demonstration is underway on Jeju Island Smart Grid Demonstration Complex in Korea, and focusing on broadband power line communication technology infrastructure is actively underway in Korea Electric Power Corporation. AMI system using power line communication technology without building a separate communication lines are available for power supply lines, but communication is impossible in occurs because admission to the power company or the ideal infrastructure for communication is not considered. In this paper, we analyze the requirements to build AMI system using Binary CDMA and powerline communications technology, and design the basic communication protocol based on Binary CDMA, implement network management and relay feature. By doing so, ways to apply Ad-hoc Binary CDMA indigenous technology to the AMI system were derived, and could build a system to make use of Wired (PLC) and wireless (Binary CDMA) simultaneously.

Effect the I-T curve and electrical characteristic of fuse elements by plated tin thickness (주석 도금 두께에 따른 퓨즈 가용체의 I-T 커브 및 전기적 특성의 영향)

  • Jin, Sang-Jun;Kim, Eun-Min;Youn, Jae-Seo;Lee, Ye-Ji;Noh, Seong-Yeo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.80-87
    • /
    • 2018
  • In recent years, due to the spread of various renewable energy power sources and the pursuit of high efficiency and low-power consumption, not only trends in the electric power industry but also the consumption, control methods, and characteristics are diversified. However, in this diversified electric power industry, the fuse (which is the core part responsible for safety) has not developed significantly in classical operation mode, and thus, fires continue to occur. In this paper, the effects of low melting-point metal plating and high melting-point metal plating on operating characteristics and IT curve movement of the fuse are investigated in a cartridge fuse, which is a classic fuse manufacturing method. The effects of plating on the thickness of the fuse are investigated, and various operating characteristics of the fuse are implemented. In addition, it is suggested that the plating of the low melting-point metal moves the rated current line of the fuse to a low rating, and moves operating characteristics to characteristics of delay operation. It is possible to design various operating characteristics using this characteristic.

Parameter Identification of 3R-C Equivalent Circuit Model Based on Full Life Cycle Database

  • Che, Yanbo;Jia, Jingjing;Yang, Yuexin;Wang, Shaohui;He, Wei
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1759-1768
    • /
    • 2018
  • The energy density, power density and ohm resistance of battery change significantly as results of battery aging, which lead to decrease in the accuracy of the equivalent model. A parameter identification method of the equivale6nt circuit model with 3 R-C branches based on the test database of battery life cycle is proposed in this paper. This database is built on the basis of experiments such as updating of available capacity, charging and discharging tests at different rates and relaxation characteristics tests. It can realize regular update and calibration of key parameters like SOH, so as to ensure the reliability of parameters identified. Taking SOH, SOC and T as independent variables, lookup table method is adopted to set initial value for the parameter matrix. Meanwhile, in order to ensure the validity of the model, the least square method based on variable forgetting factor is adopted for optimizing to complete the identification of equivalent model parameters. By comparing the simulation data with measured data for charging and discharging experiments of Li-ion battery, the effectiveness of the full life cycle database and the model are verified.

A Study on the Deterioration Process of 22kV Power Cables in Operation (운전 중인 상태에 있는 22kV 전송선로 케이블의 열화 과정해석에 대한 연구)

  • Lee, Kwan-Woo;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.3
    • /
    • pp.127-133
    • /
    • 2013
  • As an essential part of current industrial society, electric power energy is contantaly increasing in pace with the development of science and technology. In order to meet the demand of electric power, power facilities which take care of the higher voltage and bigger capacity is required. To produce and supply electric power on a sound basis the electric facilities should operate with reliability. To prevent disasters in advance, the high quality facilities should be manufactured, and a constant management should be done. When the power facilities cause accidents, the result is huge national deficits. Since the power facilities play a pivotal role in the key industry of national infrastructures of they should operate for a long time in maintaining a stable state, and the accidents can be prevented in advance. The lifetime of a power cable is considered to be 30 years at the time of manufacture, but in real fields, accidents of cable occur 8-12 years from the start of operation, resulting in a heavy loss of properties. In this paper, we will show that we have found out the cause and process of the deterioration of 22kV cable systems in operation. The result is that the process of deterioration does not follow the Weibull distribution only ; but rather, after the heat deterioration the Weibull distributed deterioration comes, then the cable is destroyed due to the partial discharge resulting from the Weibull distributed deterioration.

Smart Grid Cooperative Communication with Smart Relay

  • Ahmed, Mohammad Helal Uddin;Alam, Md. Golam Rabiul;Kamal, Rossi;Hong, Choong Seon;Lee, Sungwon
    • Journal of Communications and Networks
    • /
    • v.14 no.6
    • /
    • pp.640-652
    • /
    • 2012
  • Many studies have investigated the smart grid architecture and communication models in the past few years. However, the communication model and architecture for a smart grid still remain unclear. Today's electric power distribution is very complex and maladapted because of the lack of efficient and cost-effective energy generation, distribution, and consumption management systems. A wireless smart grid communication system can play an important role in achieving these goals. In this paper, we describe a smart grid communication architecture in which we merge customers and distributors into a single domain. In the proposed architecture, all the home area networks, neighborhood area networks, and local electrical equipment form a local wireless mesh network (LWMN). Each device or meter can act as a source, router, or relay. The data generated in any node (device/meter) reaches the data collector via other nodes. The data collector transmits this data via the access point of a wide area network (WAN). Finally, data is transferred to the service provider or to the control center of the smart grid. We propose a wireless cooperative communication model for the LWMN.We deploy a limited number of smart relays to improve the performance of the network. A novel relay selection mechanism is also proposed to reduce the relay selection overhead. Simulation results show that our cooperative smart grid (coopSG) communication model improves the end-to-end packet delivery latency, throughput, and energy efficiency over both the Wang et al. and Niyato et al. models.

Feasibility Analysis on Replacing LED Lighting with Incandescent Bulbs in Public Institution (백열 전구의 LED 조명 교체에 대한 타당성 분석 - 공공기관을 중심으로 -)

  • Park, Youn Mi;Lee, Myung Koon
    • Journal of Climate Change Research
    • /
    • v.1 no.3
    • /
    • pp.205-210
    • /
    • 2010
  • LED light has various advantages such as an energy saving effect of over 80% compared to existing lighting and environmentally friendly characteristics; however, there has been no affordable market for LED lighting because of its expensive price. This study discussed the validity of the expansion of distribution of LED lighting through an assessment of economic efficiency concerning LED lightening in order to analyze its efficiency in terms of energy savings and maintenance and repair, which will be generated as a result of the change from existing incandescent bulbs to LED lighting in the public sector. As to the target of analysis, the paper reviewed the validity of change to LED lighting as a result of the elimination of existing incandescent bulbs, by referring to 'the current incandescent bulb use and elimination performance' published by the Ministry of Knowledge Economy based on the "Elimination management system" executed by Korea Energy Management Corporation. The paper considered expenses for change, annual power savings amount and electric charges savings amount, repair and maintenance cost, $CO_2$ reduction volume, and the profit from the sale of CER (certified emission reduction). As a result of analyzing economic efficiency, when the discount rate during the change of existing incandescent bulb lighting to LED lighting is 3.26%, the profit was 8,648,400,000 won. Accordingly, NPV was analyzed to have a 'positive (+)' value, which means that this change is profitable.

Implementation of Prosumer Management System for Small MicroGrid (소규모 마이크로그리드에서 프로슈머관리시스템의 구현)

  • Lim, Su-Youn;Lee, Tae-Won
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.6
    • /
    • pp.590-596
    • /
    • 2020
  • In the island areas where system connection with the commercial power grid is difficult, it is quite important to find a method to efficiently manage energy produced with independent microgrids. In this paper, a prosumer management system for P2P power transaction was realized through the testing the power meter and the response rate of the collected data for the power produced in the small-scale microgrids in which hybrid models of solar power and wind power were implemented. The power network of the microgrid prosumer was composed of mesh structure and the P2P power transaction was tested through the power meter and DC power transmitter in the off-grid sites which were independently constructed in three places. The measurement values of the power meter showed significant results of voltage (average): 380V + 0.9V, current (average): + 0.01A, power: 1000W (-1W) with an error range within ±1%. Stabilization of the server was also confirmed with the response rate of 0.32 sec. for the main screen, 2.61 sec. for the cumulative power generation, and 0.11 sec for the power transaction through the transmission of 50 data in real time. Therefore, the proposed system was validated as a P2P power transaction system that can be used as an independent network without transmitted by Korea Electric Power Corporation (KEPCO).

A User Authentication Scheme using Blockchain in Smart Grid-based Edge Computing Environments (스마트 그리드 기반 엣지 컴퓨팅 환경에서 블록체인을 이용한 사용자 인증 기법)

  • Hakjun Lee;Youngsook Lee
    • Convergence Security Journal
    • /
    • v.22 no.1
    • /
    • pp.71-79
    • /
    • 2022
  • The smart grid system has emerged to maximize energy efficiency through real-time information exchange between power providers and consumers by combining information technology and power supply systems. The authentication schemes using blockchain in a smart grid system have been proposed, which utilize an edge server's architecture to collect and store electric power-related information and process data between a central cloud server and smart grid-IoT devices. Although authentication schemes are being proposed to enhance security in the smart grid environment, many vulnerabilities are still reported. This paper presents a new mutual authentication scheme to guarantee users' privacy and anonymity in a smart grid based on edge computing using blockchain. In the proposed scheme, we use the smart contract for the key management's efficiency, such as updating and discarding key materials. Finally, we prove that the proposed scheme not only securely establishes a session key between the smart grid-IoT device of the user and the edge server but also guarantees anonymity.

A Study for the Efficient Improvement Measures of Military EMP Protection Ability (국방 EMP 방호능력의 효율적 개선을 위한 방안 연구)

  • Jung, Seunghoon;An, Jae-Choon;Hwang, Yeung-Kyu;Jung, Hyun-Ju;Shin, Yongtae
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.1
    • /
    • pp.219-227
    • /
    • 2017
  • Current military command information system uses electronic equipment a lot on which semiconductor chip is attached. It seems its' importance will increase more with latest information communication technology developing. Electronic equipment which uses electricity contains regular tolerance to high output electric signal. And EMC specification is the standardized of this electronic equipment's tolerance. On the other hand, the Institute of Atomic Energy Research has ever declared that high output electromagnetic pulse(EMP) will be broken out within the radius of 170Km when 10kt nuclear explosion occurs at an altitude of 40Km above Seoul. Then, the region suffer from the damage of most electronic equipments. Therefore, the norm to protect the influences in that case is defined by EMP protection specification. Most common electronic equipments meet the EMC norm, but there is no way to check whether they meet the EMP norm or not. That is because it is difficult to check whether they meet EMP protection norm and is on the matter of cost. Except inevitable cases, there is no review of checking whether they meet the norm or not. Considering the above, in this research, we speculate about the measures to improve military EMP protection ability by analyzing the EMC-EMP correlation and checking the EMP protection ability of general electronic equipment through the analysis.