• 제목/요약/키워드: Electric Energy

검색결과 5,268건 처리시간 0.038초

에너지 회생 기법을 사용한 초고속 전동 사출성형기 개발 (Development of the ultra-high speed electric injection molding machine using the energy regeneration method)

  • 유현재;유성철;현창훈;박경호
    • Design & Manufacturing
    • /
    • 제10권2호
    • /
    • pp.1-5
    • /
    • 2016
  • High-speed and high-torque performance is required in the ultra-high speed electric injection molding machine field. To implement this performance, the big-size inverter is needed and the corresponding converter should be used. In this case, the whole cost for configuring the system will be increased. In this paper, we introduce a method which is able to reduce the energy and the cost for configuring the system using the energy regeneration. The energy regeneration method is based on reusing the regeneration power generated at the electric motor during decelerating the injection motion. In this paper, we demonstrate the effectiveness of the method by using the ultra-high speed injection motion.

태양광 발전을 이용한 전기자동차 배터리 충전 및 공급시스템에 관한 연구 (A Study on Battery Charging and Supply System of Electric Vehicle Using Photovoltaic Generation)

  • 최회균
    • 한국기후변화학회지
    • /
    • 제8권3호
    • /
    • pp.265-273
    • /
    • 2017
  • Recently the Paris Climate Change Accord has been officially put into effect, making global efforts to implement Greenhouse Gas (GHG) reductions, and also International environmental regulations in the automotive sector will be further strengthened. The electric vehicle, which minimizes the particulate matter generated by existing internal combustion engine automobiles, is evaluated as a representative eco-friendly automobile. However, charging the battery of an electric vehicle is not fully environment-friendly if it is fueled by electricity that is being generated by fossil fuels as an energy source. The energy generated by the photovoltaic power generation system, which is an infinite clean energy, can be used to charge an electric vehicle's battery. Currently, shortage of charging facilities, time of charging, and high battery prices are the problem of activating the supply of electric vehicles. This study is to build a conjunction between the EVBSS (Electric Vehicle Battery Supply System) and ESS (Energy Storage System), which can quickly supply the photovoltaic charged battery to the required demand. If the charged battery in the Battery Swapping Station (BSS) is swapped swiftly, it will dramatically shorten the waiting time for charging the battery. As a result, if the battery is rented when it is needed, electric vehicles can be sold without the cost of a battery, which accounts for a large portion of the total cost, then the supply of electric vehicles are expected to expand. Furthermore, it will be an important alternative to maneuver climate change by minimizing GHG emissions from internal combustion engine vehicles.

5052-H32 알루미늄 합금의 통전 소성에 미치는 에너지밀도의 영향 검증 (Evaluation of Effect of Electric Energy Density on the Electroplasticity of 5052-H32 Aluminum Alloys)

  • 염경호;홍성태;정용하;한경식;한흥남;김문조
    • 대한기계학회논문집A
    • /
    • 제39권7호
    • /
    • pp.659-663
    • /
    • 2015
  • 본 연구에서는 다른 게이지 체적을 가지는 시편들의 동일한 에너지밀도 하에서의 통전소성 인장 거동을 실험을 통하여 비교하였다. 5052-H32 알루미늄 합금의 통전소성 인장실험의 결과는 시편의 게이지 길이나 폭 혹은 체적에 상관없이 동일한 에너지밀도가 가해질 때 거의 유사한 통전소성 특성을 보여준다. 특히 통전소성 인장시험의 전형적인 현상인 stress-drop 의 크기를 비교할 때, 소재의 통전소성이 개별적인 전류밀도와 통전시간이 아닌 에너지밀도에 의해서 영향을 받는다는 것을 확인할 수 있다. 본 논문의 결과는 통전소성 현상을 응용한 제조공정의 개발 시 공정설계변수들 중 전류밀도와 통전시간 두 가지를 에너지밀도 하나로 줄일 수 있다는 것을 의미하며 이는 향 후 다양한 통전소성 기반 제조기술의 개발에 이바지 할 것으로 예상된다.

탑상형 아파트의 층별 전기와 가스 부하량 비교평가 (Comparative Evaluation of Electric Power and LNG Load according to Floor level of Tower-Type Apartments)

  • 김준현;최진호;엄정섭
    • 환경영향평가
    • /
    • 제20권4호
    • /
    • pp.465-475
    • /
    • 2011
  • It is known that energy consumption in bottom floor of typical Korean-style apartment is the highest. Previous studies for energy consumption in accordance with floor level appear to be very limited due to the dependence on single energy variable such as electric power or LNG separately, based on past flat type of apartment. Acknowledging these constraints, an empirical study for a tower type emerged recently as new style of apartment in South Korea was conducted to demonstrate how a comprehensive evaluation for both electric power and LNG consumption can be used to assist in monitoring the total energy consumption in terms of floor specific settings. It was possible to identify that energy consumption in bottom floor is lesser than that of top floor, to the contrary, fact known from previous study. Also electric power consumption in top floor was identified as 15% higher than that of floor in the least. It is anticipated that this integrated utilization of electric power and LNG data would present more scientific and objective evidence for the energy load among floor level of tower type apartment by overcoming serious constraints suffered from the past single variable investigation. Ultimately, the result in this paper could be used as a valuable reference to providing priority for energy saving activities in top floor such as cool roof or green roof.

수중음원으로써의 전기방전시스템- I. 낮은 전기에너지로부터의 음압펄스 - (Electric Spark System as Underwater Acoustic Source - I. Pressure pulses from low electric energy -)

  • 김성부;김상한
    • 한국음향학회지
    • /
    • 제15권4호
    • /
    • pp.32-35
    • /
    • 1996
  • 0.4~1.6kJ의 비교적 낮은 전기에너지를 갖는 수중 전기방전 시스템으로부터 발생하는 음파의 파형을 깊이별, 거리별로 관측하였다. 파형의 특성은 이미 보고된 에너지와 수심 의존도를 그대로 유지하고 있으나, 다른 두가지 특징적인 현상들이 관측되었다. 첫째는 내파에 의한 1차 bubble 펄스들의 피크 음압이 초기 충격파의 것보다 높게 관측되었는데, 이것은 10kJ 이상의 고에너지 방전시스템에서만 뚜렷하게 나타나던 현상이다. 둘째는 음향에너지 변환효율이 통상 5kJ에서 0.02, 1kJ에서 0.01로 저에너지대에서 그효율이 감소하는 경향을 보인다고 보고되었으나 1kJ의 부근에서는 0.01로 그 효율이 다시 일정하게 유지되고 있음이 확인되었다.

  • PDF

Energy Management and Performance Evaluation of Fuel Cell Battery Based Electric Vehicle

  • Khadhraoui, Ahmed;SELMI, Tarek;Cherif, Adnene
    • International Journal of Computer Science & Network Security
    • /
    • 제22권3호
    • /
    • pp.37-44
    • /
    • 2022
  • Plug-in Hybrid electric vehicles (PHEV) show great potential to reduce gas emission, improve fuel efficiency and offer more driving range flexibility. Moreover, PHEV help to preserve the eco-system, climate changes and reduce the high demand for fossil fuels. To address this; some basic components and energy resources have been used, such as batteries and proton exchange membrane (PEM) fuel cells (FCs). However, the FC remains unsatisfactory in terms of power density and response. In light of the above, an electric storage system (ESS) seems to be a promising solution to resolve this issue, especially when it comes to the transient phase. In addition to the FC, a storage system made-up of an ultra-battery UB is proposed within this paper. The association of the FC and the UB lead to the so-called Fuel Cell Battery Electric Vehicle (FCBEV). The energy consumption model of a FCBEV has been built considering the power losses of the fuel cell, electric motor, the state of charge (SOC) of the battery, and brakes. To do so, the implementing a reinforcement-learning energy management strategy (EMS) has been carried out and the fuel cell efficiency has been optimized while minimizing the hydrogen fuel consummation per 100km. Within this paper the adopted approach over numerous driving cycles of the FCBEV has shown promising results.

Pulse Density Modulation Controlled Series Load Resonant Zero Current Soft Switching High Frequency Inverter for Induction-Heated Fixing Roller

  • Sugimura, Hisayuki;Kang, Ju-Sung;Saha, Bishwajit;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.226-228
    • /
    • 2006
  • This paper presents the two lossless auxiliary inducors-assisted voltage source type half bridge(single ended push pull:SEPP) series resonant high frequency inverter for induction heated fixing roller in copy and printing machines. The simple high-frequency inverter treated here can completely achieve stable zero current soft switching (ZCS) commutation forwide its output power regulation ranges and load variations under constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operatprinciple is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZCS operation commutation, together with its output effective power regulation charactertics-based on the high frequency PDM strategy. The experimenoperating performances of this voltage source SEPP ZCS-PDM series resonant high frequency inverter using IGBTs are illustrated as compared with computer simulation results and experimenones. Its power losses analysis and actual efficiency are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliimplemented here is proved from the practical point of view.

  • PDF

탑상형 아파트의 외피개방유형에 따른 전기에너지 사용량 사례 분석 (Analysis the case study of tower type apartment by opening types of building surface)

  • 김유원;이현수;김은혜
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.111-115
    • /
    • 2011
  • The purpose of this study was the analysis of electric energy consumption with the case study of tower type apartment's opening of building surface. We analyze the relationship between tower type apartment's opening of building surface and using electric energy consumption. The results of this study are: 1) The highest energy consumption of electric energy was on August without any influence of opening types of building surface. 2) Also, the south-west sides consumption of August was 848 kWh on Type B(one side opening) and it was the highest usage. 3) A house if facing west used more electricity than facing east when its opening of building surface's datum level is facing south. However, the house of facing east used more power than west when its opening of building surface's datum level is facing north. 4) When opening of building surface is facing on north-west or north-east, the opening of building surface's side of west and east used more electric power than north-west or north-east sides.

  • PDF

Dual-model Predictive Direct Power Control for Grid-connected Three-level Converter Systems

  • Hu, Bihua;Kang, Longyun;Feng, Teng;Wang, Shubiao;Cheng, Jiancai;Zhang, Zhi
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1448-1457
    • /
    • 2018
  • Many researchers devote themselves to develop model-predictive direct power control (MPDPC) so as to accelerate the response speed of the grid-connected systems, but they are troubled its large computing amount. On the basis of MPDPC, dual MPDPC (DMPDPC) is presented in this paper. The proposed algorithm divides the conventional MPDPC into two steps. In the first step, the optimal sector is obtained, which contains the optimal switching state in three-level converters. In the second step, the optimal switching state in the selected sector is searched to trace reference active and reactive power and balance neutral point voltage. Simulation and experiment results show that the proposed algorithm not only decreases the computational amount remarkably but also improves the steady-state performance. The dynamic response of the DMPDPC is as fast as that of the MPDPC.

원전 급수펌프 구동용 터빈 제어시스템 개발 (A Development of Digital Control System for FWPT In Nuclear Power Plant)

  • 최인규;정창기;김병철;김종안;우주희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1885-1886
    • /
    • 2006
  • The thermal energy from nuclear fission is transferred to the steam generator which is a kind of a large heat exchanger. After the feedwater is injected into the steam generator and absorbs the thermal energy, it is converted into the steam. This steam goes into the turbine. The balance between the generated energy and the consumed energy is required for the nuclear power plant to be stable. For the purpose of which, the feed water, a parameter for energy transfer, should be controlled in stability. Usually, the nuclear power plants are operated in base load in the view of power system for the stability of fission system. Therefore, though there will be almost no unbalance, there can be some instability from unbalance in case of startup/shutdown or disturbance. In this case, the controllability of feedwater pump is very important for the quick recover of stability.

  • PDF