• 제목/요약/키워드: Electric Current

검색결과 4,820건 처리시간 0.205초

Electric current control of creation and annihilation of sub-100 nm magnetic bubbles examined by full-field transmission soft X-ray microscopy

  • Je, Soong-Geun;Jung, Min-Seung;Im, Mi-Young;Hong, Jung-Il
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1201-1204
    • /
    • 2018
  • The effect of electric current pulses on a sub-100 nm magnetic bubble state in a symmetric Pt/Co multilayer was directly observed using a full-field transmission soft X-ray microscope (MTXM). Field-induced evolution of the magnetic stripe domains into isolated bubbles with their sizes down to 100 nm was imaged under varying external magnetic fields. Electric current pulses were then applied to the created magnetic bubbles, and it was observed that the bubbles could be either created or annihilated by the current pulse depending on the strength of applied magnetic field. The results suggest that the Joule heating plays a critical role in the formation and/or elimination of the bubbles and skyrmions. Finally, the schematic phase diagram for the creation and annihilation of bubbles is presented, suggesting an optimized scheme with the combination of magnetic field and electric current necessary to utilize skyrmions in the practical devices.

방전가공에서 전기적 변화가 갖는 방전 특성에 관한 연구 (A study for its Characteristics with Electric Variation in an Electrical Discharge Machining)

  • 신근하
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1996년도 춘계학술대회 논문집
    • /
    • pp.132-136
    • /
    • 1996
  • A Study is a experiment which is figure out to aptimum discharge cutting condition of the surfaceroughness, electric discharging speed and electro wear ratio with Ton Toff and V(voltage) as an input condition according to the current(Ip) in an electric spark machine ; 1)Electrode is utilized Cu(coper) and Graphite. 2)Work piece is used the material of carbon steel. The condition of experiment is; 1)Current is varied 0.7(A) to 50(A). 2)Pulse time(Ton) is varied 3($\mu$s) to 240($\mu$s) and also Toff is varied 7($\mu$s) to 20($\mu$s). 3)The time of electric discharging to work piece in each time is 30(min) to 60(min) 4)After the upper side of work piece was measured in radius (5${\mu}{\textrm}{m}$) of syulus analyzed the surface roughness to made the table and graph of Rmax by yielding data. 5)Electro wear ratio is; \circled1Coper was measured cx-machining and post machining but the electronic baiance. \circled2The ex-machining of graphite measured by it, the post-machining was found the data from volume specific gravity and analyzed to made its table and graph on ground the data 6)In order to keep the accuracy of voltage affected to the work piece was equipped with the A.V.R(Automatic Voltage Regulator). 7)The memory scope was sticked to the electric spark machine. 8)In order to preserve the precision of current, to get rid of the noise occured by internal resistance of electric spark machine and to force injecting for the discharge fluid, it made the fixed table for a work piece to minimize the work error by means of one's failure during the electric discharging According to above results, the surface roughness by the variation of electrodw and current was analyzed to compare KS(Korea Standards) It was decided the optimum condition of electric discharge cutting through analyzing the effect of electric discharge speed and electro wear ratio.

  • PDF

5052-H32 알루미늄 합금의 통전 소성에 미치는 에너지밀도의 영향 검증 (Evaluation of Effect of Electric Energy Density on the Electroplasticity of 5052-H32 Aluminum Alloys)

  • 염경호;홍성태;정용하;한경식;한흥남;김문조
    • 대한기계학회논문집A
    • /
    • 제39권7호
    • /
    • pp.659-663
    • /
    • 2015
  • 본 연구에서는 다른 게이지 체적을 가지는 시편들의 동일한 에너지밀도 하에서의 통전소성 인장 거동을 실험을 통하여 비교하였다. 5052-H32 알루미늄 합금의 통전소성 인장실험의 결과는 시편의 게이지 길이나 폭 혹은 체적에 상관없이 동일한 에너지밀도가 가해질 때 거의 유사한 통전소성 특성을 보여준다. 특히 통전소성 인장시험의 전형적인 현상인 stress-drop 의 크기를 비교할 때, 소재의 통전소성이 개별적인 전류밀도와 통전시간이 아닌 에너지밀도에 의해서 영향을 받는다는 것을 확인할 수 있다. 본 논문의 결과는 통전소성 현상을 응용한 제조공정의 개발 시 공정설계변수들 중 전류밀도와 통전시간 두 가지를 에너지밀도 하나로 줄일 수 있다는 것을 의미하며 이는 향 후 다양한 통전소성 기반 제조기술의 개발에 이바지 할 것으로 예상된다.

Optical Current Measuring System for Compensating Interference by Adjacent Electric Wires

  • Cho, Jae-Kyong
    • Journal of Magnetics
    • /
    • 제12권4호
    • /
    • pp.156-160
    • /
    • 2007
  • In this paper, we analyze the errors associated with magnetic field interference for fiber-optic current sensors working in a three-phase electric system and provide a solution to compensate the interference. For many practical conductor arrangements, the magnetic filed interference may cause errors unacceptable for the accuracy requirements of the sensors. We devised a real time compensation method for the interference by introducing geometric and weight factors. We realized the method using simple electronic circuits and obtained the real time compensated outputs with errors of ${\pm}1%$.

Current and voltage loading tests off resistive SFCL

  • 최효상;현옥배;김혜림;황시돌;박권배
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.241-246
    • /
    • 2002
  • We have performed the current and voltage loading tests of resistive superconducting fault current limiters (SFCLS) based on $YBa_2$$Cu_3$$O_{7}$(YBCO) films with the diameter of 2 inch. The SFCL consists of meander-type YBCO stripes covered with 200 nm Au layer grown in situ for current shunt and heat dispersion at hot spots. The minimum quench current of an SFCL unit was about 25 Apeak. Seven SFCL units were connected in parallel fur the current load ing tests at power source of 100 $V_{rms}$ $/2,000A_{rms}$. This SFCL units had maximum limiting current of 170 Apeak during the fault instant and then successfully controlled the fault current below 100 Apeak within 1~2 msec after short circuit. Increased short current also reduced the quench completion time with little change of current limiting characterization. We connected six SFCL units in series fur the voltage loading tests at power source of $1,200 V_{rms}$/170 $A_{rms}$ at this time. The shunt resistors were inserted into each SFCL unit to eliminate power imbalance originated from serial connection of SFCL units. Each SFCL unit was quenched simultaneously during the fault condition. The current increased up to 40 $A_{peak}$ and decreased to 14 $A_{peak}$ after 3 cycles. Quench was completed within 1 msec after the fault. We confirmed operating characteristics of 140 kVA($120 A_{rms}$ $\times$ 1,200 $V_{rms}$) SFCL and presented the manufacturing possibility of 3.3 kV SFCL using 4 inch YBCO films.BCO films.lms.

  • PDF

교류전기철도 급전시스템의 전차선 전압해석 (Analysis for Catenary Voltage of The ATs-Fed AC Electric Railroad System)

  • 이승혁;정현수;김진오
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(I)
    • /
    • pp.490-496
    • /
    • 2002
  • This paper presents exact Autotransformers(ATs)-fed AC electric Railroad system modeling using constant current mode far locomotives. An AC electric railroad system is rapidly changing single-phase load, and at a feeding substation, 3-phase electric power is transferred to paired directional single-phase electric power. As the train moves along a section of line between two adjacent ATs. The proposed AC electric railroad system modeling method considers the line self-impedances and mutual-impedances. The constant current mode model objectives are to calculate the catenary and rail voltages with the loop equation. When there are more than one train in the AC electric railroad system, the principle of superposition applies and the only difference between the system analyses for one train. Finally, this paper shows the general equation of an AC electric railroad system, and that equation has no relation with trains number, trains position, and feeding distance.

  • PDF

단권변압기 교류전기철도 급전시스템의 전차선 전압해석 (Analysis for Catenary Voltage of The ATs-Fed AC Electric Railroad System)

  • 정현수;이승혁;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권9호
    • /
    • pp.493-499
    • /
    • 2003
  • This paper presents exact Autotransformers(ATs)-fed AC electric Railroad system modeling using constant current mode for locomotives. An AC electric railroad system is rapidly changing single-phase load, and at a feeding substation, 3-phase electric power is transferred to paired directional single-phase electric power. As the train moves along a section of line between two adjacent ATs. The proposed AC electric railroad system modeling method considers the line self-impedances and mutual-impedances. The constant current mode model objectives are to calculate the catenary and rail voltages with the loop equation. When there are more than one train in the AC electric railroad system, the principle of superposition applies and the only difference between the system analyses for one train. Filially, this paper shows the general equation of an AC electric railroad system, and that equation has no relation with trains number, trains position, and feeding distance.

전기 감전 체험 교육을 위한 저주파 전류 자극기의 인체 자극 임계값 (Human Stimulation Threshold of Interferential Current Type Low Frequency Stimulator for Electric Shock Experience Education)

  • 전정채;김재현;유재근
    • 한국산학기술학회논문지
    • /
    • 제13권10호
    • /
    • pp.4768-4772
    • /
    • 2012
  • 전기감전 사고를 예방하기 위해서는 주입식 교육 보다는 체험식 교육이 더욱 효과적이다. 그러나 전기감전 체험형 교육 시스템을 위해서는 감전을 체험할 수 있도록 인체에 대한 적절한 물리적 자극이 필요하다. 본 논문에서는 간섭전류형자극기(Interferential Current Type Low Frequency Stimulator)를 감전사고 체험교육에 이용하기 위하여 인체에 대한 자극의 임계값을 실험하였다. 그리고 아동과 성인으로 구분된 연령별 자극 값을 산출하였다. 본 연구의 결과는 전기 감전 체험형 교육 시스템에 적용 가능할 것이다.