• Title/Summary/Keyword: Electric Coupling

Search Result 445, Processing Time 0.045 seconds

An Indirect Method to Monitor Plasma Status in a Transformer Coupled Plasma

  • Yu, Dae-Ho;An, Seung-Gyu;Kim, Ji-Hun;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.216-216
    • /
    • 2011
  • There have been various direct or indirect methods to measure the characteristics of plasma. Comparing to direct method like Langmuir probe method, indirect measurements which give information as some external parameters like current, voltage, or phase are easier to obtain. In this research, an indirect method to measure averaged plasma density in a transformer coupled plasma(TCP) has been proposed and evaluated. With a simple analytic model connecting electrical characteristics to plasma impedance, direct measurement via double Langmuir probe has been performed. This result may play a meaningful role to diagnose TCP or similar plasma sources

  • PDF

Analysis of the Earth Resistance for the Tower Footing of T/L (송전선로 철탑기초의 접지저항 해석)

  • Lee, H.G.;Ha, T.H.;Bae, J.H.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.344-346
    • /
    • 2001
  • The sharing of common corridors by electric power transmission lines and pipelines is becoming more common place. However, such corridor sharing can result in undesired coupling of electromagnetic energy from the power lines to the near facilities. During a fault on any of the transmission lines, energization of the earth by supporting structures near the fault can result in large voltages appearing locally between the earth and the steel wall of any nearby pipeline. This paper presents the outline of the tower footings for the transmission lines having been used in KEPCO and analyzes the earth resistance for operation method of the tower footing, that is contact presence for the anchor and reinforcing rob of the tower and foundation presence of the underground wiring.

  • PDF

Dual-band Frequency Selective Surface Bandpass Filters in Terahertz Band

  • Qi, Limei;Li, Chao
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.673-678
    • /
    • 2015
  • Terahertz dual-band frequency selective surface filters made by perforating two different rectangular holes in molybdenum have been designed, fabricated and measured. Physical mechanisms of the dual-band resonant responses are clarified by three differently configured filters and the electric field distribution diagrams. The design process is straightforward and simple according to the physical concept and some formulas. Due to the weak coupling between the two neighboring rectangle holes with different sizes in the unit cell, good dual-band frequency selectivity performance can be easily achieved both in the lower and higher bands by tuning dimensions of the two rectangular holes. Three samples are fabricated, and their dual-band characteristics have been demonstrated by a THz time-domain spectroscopy system. Different from most commonly used metal-dielectric structure or metal-dielectric-metal sandwiched filters, the designed dual-band filters have advantages of easy fabrication and low cost, the encouraging results afforded by these filters could find their applications in dual-band sensors, THz communication systems and other emerging THz technologies.

Heat source modeling of laser arc hybrid welding considering keyhole formation (키홀 형성을 고려한 레이저 아크 하이브리드 용접 열원 모델링)

  • Jo, Yeong-Tae;Na, Seok-Ju
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.97-99
    • /
    • 2005
  • Laser arc hybrid process is actively researched as a new welding method since it has several advantages by the combination of laser beam and electric arc. By the coupling of two different heat sources, laser and arc mutually assist and influence. High power laser can make the deep keyhole and arc plasma can form the large bead shape. In this paper the effect of two different heat sources to weld bead are investigated and as a result of analysis, it is shown that the lower part of keyhole is heated by laser and the upper part of weld pool is dominantly heated by arc.

  • PDF

The modeling of the IPT system used for PRT (Personal Rapid Transmit) (소형궤도 차량용 유도전력급전 계통 모델링)

  • Lee Byung-Song;Bae Chang-Han;Byun Yeun-Sub;Han Kyung-Hee
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1413-1418
    • /
    • 2004
  • This paper shows the analysis of the inductive power transfer system in conjunction with series resonant converter operating variable high frequency. Of particular interest is the sensitivity of the complete system to variations in operational frequency and parameters. In inductive power transfer system, electrical power is transferred from a primary winding in the form of a coil or track, to one or more isolated pick-up coils that may relative to the primary. The ability to transmit power without contact enables high reliability and easy maintenance that allows inductive power transfer system to be implemented in hostile environments. This technology has found application in many fields such as electric vehicles, PRT(Personal Rapid Transit) etc. The coupling between the primary and secondary is then presented to include the effects of parameter and operational frequency variation.

  • PDF

Modeling of coupling device for crash analysis of an electric vehicle (전동차 충돌해석을 위한 연결장치의 모델링)

  • Kim Young-Hoon;Kim Ki-Nam;Jang Hyun-Mog;Park Yeong-Il
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.640-645
    • /
    • 2004
  • In this thesis, the impact analysis for the shunting procedure using the dynamic buffer characteristics of the coupler was developed. In this study, each car was modeled as one dimensional element by using the equivalent system. After the impact, the slip exists only between wheel and rail in the braked trainset. For this analysis the analysis code named the POTAS-MSM (Power Transmission Analysis Software Multi Slip Mechanism) which was developed for the numerical analysis of dynamic system is developed. The validation of this analysis was proven by comparing the numerical results with the results of world-famous S company which is located in Europe.

  • PDF

Calculations of Polarizabilities by Integral Hellmann-Feynman Theorem (Integral Hellmann-Feynman Theorem에 의한 Polarizability의 평가)

  • Kim, Ho-Jing;Cho, Ung-In
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.127-131
    • /
    • 1970
  • The variational approach for the direct evaluation of the energy difference ${\Delta}$E is studied. The method is based on the differential equation corresponding to the integral Hellmann-Feynman formula. The ${\Delta}$E is given by the expectation value of the Hermitian operator which does not involve the 1/$r_{ij}$ term. Because of its variational nature of the method, the coupling problem of the differential equations which are encountered in perturbation treatment does not occur. The method is applied to the evaluation of the electric polarizabilities of the Helium isoelectronic series atoms. The result is in good agreement with the experiment. The method is compared with the recent works of Karplus et al.

  • PDF

The Novel Configuration for Building Energy System Including Build ins Microgrid (빌딩 마이크로그리드가 포함된 새로운 빌딩에너지 시스템 구축방향에 관한 연구)

  • Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.235-240
    • /
    • 2008
  • The recent development of efficient thermal prime movers for distributed generation id changing the focus of the production of electricity from large centralized power plants to local generation units scattered over the territory. The scientific communality is addressing the analysis and planning of the distributed energy resources(der) with wide spread approaches, taking into account technical, environmental, economical and social issues. The coupling of cogeneration system to absorption/electric chillers or heat pumps as well as the interactions with renewable sources, allow for setting up multi-generation systems for building cooling heating and power(BCHP) systems of different energy vectors such as electricity, heat(at different enthalpy levels), cooling power, hydrogen, various chemical substances and so forth. Adoption of the composite multi-generation systems may lead to significant benefits in term of higher efficiency, reduced $CO_2$ emissions and enhanced economy. This paper outlines the main aspects of the BCHP system framework, illistrating its characteristics and summarizing the relevant distributed multi-generation structures.

  • PDF

Design and Characteristic Analysis of MC-LOA taking into account the Magnetic Circuit unequivalence (자기회로의 불평형을 고려한 MC-LOA의 설계 및 특성 해석)

  • Eum, Sang-Joon;Kim, Duk-Hyun;Kang, Gyu-Hong;Hong, Jung-Pyo;Kim, Gyu-Tak
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.145-147
    • /
    • 1999
  • A voice type Moving Coil Linear Oscillatory Actuator(MC-LOA) has unbalanced magnetic circuit structure. Its asymmetric magnetic flux distribution along the mover directions causes shifting of displacement center to one side. Therefore, this paper analyzes both thrust and displacement characteristics and settles the unbalanced flux problem by performing shape optimization. The propriety of the improved design model has been verified by dynamic analysis based on the coupling of kinetic and electric equations.

  • PDF

Analysis on Electrostatic Coupling around High speed Railway Feed System (고속철도 교류 급전계통 주변의 정전유도 영향 분석)

  • Myung, S.H.;Lee, J.B.;Kim, E.S.;Min, S.W.;Lee, J.W.;Lee, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1390-1392
    • /
    • 2000
  • In this paper, a numerical calculation method based on CSM has been described. The electric field must be nonuniform even close to railway feed system. In that case, to calculate induced voltage, this paper uses the mutual capacitances between a conductor and railway feed system. The induced voltages of a conductor located at point (height=4m, distance=8m) near by railway feed system are calculated from 370V to 668V.

  • PDF