• Title/Summary/Keyword: Electric Control System

Search Result 2,785, Processing Time 0.026 seconds

Optical Sensor Technology for Supervisory and Control of Electric Power System (전력 시스템 감시 제어용 광센서 기술)

  • Kim, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2189-2191
    • /
    • 2000
  • Electric power systems are becoming advanced by using new technology year by year However, in electric power system environments. electromagnetic interference occurs in measurement, supervisory and control systems, especially in sensors. Optical sensor technologies are useful for solving the problem, since they are not affected by electromagnetic interference because they are composed of insulting materials. In this paper, some applications of optical sensor technology to electric power systems are introduced.

  • PDF

Effects of Wind Generation Uncertainty and Volatility on Power System Small Signal Stability

  • Shi, Li-Bao;Kang, Li;Yao, Liang-Zhong;Qin, Shi-Yao;Wang, Rui-Ming;Zhang, Jin-Ping
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.60-70
    • /
    • 2014
  • This paper discusses the impacts of large scale grid-connected wind farm equipped with permanent magnet synchronous generator (PMSG) on power system small signal stability (SSS) incorporating wind generation uncertainty and volatility. Firstly, a practical simplified PMSG model with rotor-flux-oriented control strategy applied is derived. In modeling PMSG generator side converter, the generator-voltage-oriented control strategy is utilized to implement the decoupled control of active and reactive power output. In modeling PMSG grid side converter, the grid-voltage-oriented control strategy is applied to realize the control of DC link voltage and the reactive power regulation. Based on the Weibull distribution of wind speed, the Monte Carlo simulation technique based is carried out on the IEEE 16-generator-68-bus test system as benchmark to study the impacts of wind generation uncertainty and volatility on small signal stability. Finally, some preliminary conclusions and comments are given.

A Study on Powering Characteristic on Speed Variation of Propulsion System of Prototype 8200 Electric Locomotive (축소형 8200호대 전기기관차 추진시스템의 속도변화에 따른 역행특성 연구)

  • Jung, No-Geon;Chang, Chin-Young;Yun, Cha-Jung;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1467-1472
    • /
    • 2014
  • This paper study on powering characteristic on speed variation of propulsion system of prototype 8200 electric locomotive propulsion system through simulation modeling. For this purpose, it being applied in the field of railway IGBT (Insulated Gate Bipolar Transistor) elements are used. Converter was performed PLL (Phase-Locked Loop) control method that is used to control the phase and output voltage, and the inverter was carried an indirect vector control method to control the speed of traction motor. The results of simulation by modeling and experimental unit, we was confirmed that converter is controlled a unity power factor and output voltage by reference voltage. Also traction motor was controlled by indirect vector control and SVPWM inverter switching method very well.

Experimental Study on Optimal Operation Strategies for Energy Saving in Building Central Cooling System (건물 중앙냉방시스템의 에너지절감을 위한 최적운전 방안에 관한 실험적 연구)

  • Hwang, Jin-Won;Ahn, Byung-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4610-4615
    • /
    • 2013
  • In this study, optimal operation strategies to save the electric energy and power price in the building central cooling system is researched by experiments. The optimal strategies of demand response control and outdoor temperature reset control algorithms are applied by consideration the electric energy and power price according to the energy consumption characteristics. The suggested optimal control method shows better responses in the power price and energy consumption in comparison with the conventional one and saves energy consumption by 9.5% and electronic price by 15.7%, respectively.

Mitigation of Load Frequency Fluctuation Using a Centralized Pitch Angle Control of Wind Turbines

  • Junqiao, Liu;Rosyadi, Marwan;Takahashi, Rion;Tamura, Junji;Fukushima, Tomoyuki;Sakahara, Atsushi;Shinya, Koji;Yosioka, Kazuki
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.1
    • /
    • pp.104-110
    • /
    • 2013
  • In this paper an application of centralized pitch angle controller for fixed speed wind turbines based wind farm to mitigate load frequency fluctuation is presented. Reference signal for the pitch angle of each wind turbine is calculated by using proposed centralized control system based on wind speed information. The wind farm in the model system is connected to a multi machine power system which is composed of 4 synchronous generators and a load. Simulation analyses have been carried out to investigate the performance of the controller using real wind speed data. It is concluded that the load frequency of the system can be controlled smoothly.

Design and Experimental Evaluation of a Robust Force Controller for a 6-Link Electro-Hydraulic Manipulator via H$_{\infty}$ Control Theory

  • Ahn, Kyoung-Kwan;Lee, Byung-Ryong;Yang, Soon-Yong
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.7
    • /
    • pp.999-1010
    • /
    • 2003
  • Uninterrupted power supply has become indispensable during the maintenance task of active electric power lines as a result of today's highly information-oriented society and increasing demand of electric utilities. This maintenance task has the risk of electric shock and the danger of falling from high place. Therefore it is necessary to realize an autonomous robot system using electro-hydraulic manipulators because hydraulic manipulators have the advantage of electric insulation and power/mass density. Meanwhile an electro-hydraulic manipulator using hydraulic actuators has many nonlinear elements, and its parameter fluctuations are greater than those of an electrically driven manipulator. So it is relatively difficult to realize not only stable contact work but also accurate force control for the autonomous assembly tasks using hydraulic manipulators. In this paper, the robust force control of a 6-link electro-hydraulic manipulator system used in the real maintenance task of active electric lines is examined in detail. A nominal model for the system is obtained from experimental frequency responses of the system, and the deviation of the manipulator system from the nominal model is derived by a multiplicative uncertainty. Robust disturbance observers for force control are designed using this information in an H$\_$$\infty$/ framework, and implemented on the two different setups. Experimental results show that highly robust force tracking by a 6-link electro-hydraulic manipulator could be achieved even if the stiffness of environment and the shape of wall change.

The example of improvement and development for SCARA system operation in Korea Electric Power Corporation (전력회사의 원방 감시 제어 시스템의 운용 개선 사례)

  • 우희곤
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.164-168
    • /
    • 1986
  • This paper describes an overview of the remote Supervisory Control And Data Acquisition (SCADA) System for automatic operation of Electric power system in KEPCO. And the example of improvement and development for effective operation of the SCADA is reported briefly.

  • PDF

Study on Economical M&V Methoodology for the Lighting Control System (조명제어시스템 경제적인 실적확인 기법 연구)

  • Choi, Kyung-Shik;Han, Seung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.163-167
    • /
    • 2009
  • Although the domestic electric power consumption of lighting have shared 20${\sim}$30 % of the national electric power consumption, the spread of lighting control system which can reduce the electric power consumption have been insignificant. The government have set the demonstration project and given the incentive to promote the spread of lighting control system since 2008. The M&V (Measurement and Verification) methodology for lighting control system have not been set yet in our country, but the direct measurement was suggested in US. The direct measurement methodology can increase the accuracy of measurement, but it cost much money to burden a customer. This study have suggested a new M&V methodology which cost low and is simple relatively. I had measured the amount of electric consumption through both the direct measurement and the new M&V program computation, and have analyzed the deviation. The amount of electric consumption measured by the new M&V program computation have agreed with one by the direct measurement within the error range of the instrumentation in case of lab scale test, and the 4${\sim}$8 % deviation have existed in case of field evaluation.

  • PDF

A study on the Implementation of a Remote Control System for Peak Load Clipping (첨두부하 억제를 위한 원격부하제어시스템 개발 및 적용에 관한 연구)

  • Cho, Seon-Ku;Moon, Hong-Suk;Yoon, Kap-Koo;Lee, Won-Bin
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.165-168
    • /
    • 1995
  • The recent rapid growth of air conditioning load has become a major reason of peak load increase in summer. In connection with this, we surveyed the load management projects of utilities world-wide and their detailed activities. This study is to develop a remote load control system using computer and radio communications. We finished the field-test of this system on August 1995 in Seoul area. During the field-test, the remote load control of air conditioners was proved to be well-timed. Two control modes, group control and all control, are available for the user to select. The transmission reliability of the load control signal was very good and the functions of system hardware as well as the software were excellent. So we confirmed the applicability of the load control system including the paper communication network. In this paper, detailed information on the system functions and experimental results are described.

  • PDF

Development of RTDS-MATLAB Integrated Simulation Environment for Development and Verification of Voltage Measurement based CVR Control Algorithm (전압계측기반 CVR제어 알고리즘 개발 및 검증을 위한 RTDS-MATLAB 연동 시뮬레이션 환경 개발)

  • Go, Seok-Il;Ahn, Seon-Ju;Choi, Joon-Ho;Nam-Koong, Won;Shin, Chang-Hoon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.549-556
    • /
    • 2016
  • CVR is a technique for reducing power consumption by reducing the voltage of the system and many demonstrations and studies have been conducted in the past. Recently, SCADA-based or AMI-based VVC have been developed and the CVR is used as an important operation mode. Using a variety of instruments, CVR determines the optimal VVC control references by closed loop control. In this paper, we implemented RTDS-MATLAB integrated simulation environment for development and verification of CVR control algorithm based on voltage measurement. The voltage control device of distribution system was modeled using RTDS and MATLAB has constructed a controller that can measure and control the voltage of the simulation system of RTDS. After the capacitor, which is a reactive power control device, flattens the voltage of the system, the control algorithm reduces the voltage of the system by tap control of the OLTC based on the flatten voltage. The proposed system was verified by simulations.