• Title/Summary/Keyword: Electric Ballast

Search Result 46, Processing Time 0.029 seconds

Techniques of Management and Energy saving by using power installation (전력사용설비의 에너지 절감방안 및 관리를 위한 진단기법)

  • Chung, Choon-Byeong;Jeon, Kee-Young;Hahm, Nyun-Gun;Kim, Dae-Gyun;Lee, Sang-Chip;Oh, Bong-Hwan;Lee, Hoon-Gu;Han, Kyung-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.329-333
    • /
    • 2004
  • The human beings have increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life. We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, inteligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

A Study on Energy saving for refrigeration warehouse (냉동냉장창고에 대한 에너지 절약에 대한 연구)

  • Chung, Choon-Byeong;Kim, Dae-Gyun;Kim, Ik-Hwan;Lee, Sang-Chip;Hahm, Nyun-Gun;Jeon, Kee-Young;Lee, Hoon-Gu;Han, Kyung-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.270-274
    • /
    • 2005
  • The human beings have increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life. We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, inteligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

Design of the Electric Ballast for 70W CDM Lamp (70W CDM 램프용 전자식 안정기 설계)

  • Choe, Hyeon-Hui;Choi, Wang-Seop;Park, Chong-Yun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.940_941
    • /
    • 2009
  • Dual Buck Inverter구조를 가지는 70W CDM 램프용 전자식 안정기의 제어기를 설계하였다. 전자식 안정기는 EMI filter, Active PFC, Dual Buck Inverter, Igniter, SMPS로 구성 된다. 제어기는 크게 2개로 구분 할 수 있다. MC33262를 이용하여 Inverter의 전압, 전류를 센싱 받아 70kHz의 Zero Voltage Switching을 위한 제어기와 시간의 경과에 따라 PFC의 출력 전압 제어, Ignition Pulse 제어 및 무부하 보호를 위한 제어기로 구성되어 있다. 본 논문은 ATmega8을 이용하여 제어기를 설계하였고 실험으로 시간의 경광 따른 안정기의 제어가 안정적인 동작을 하고 있음을 증명하였다.

  • PDF

A Study on Refrigeration warehouse operation for Energy saving technique (에너지 절감 기법을 적용한 냉동 냉장 창고 운영에 관한 연구)

  • Kim, Dae-Gyun;Kwon, Jung-Dong;Hahm, Nyun-Gun;Lee, Sang-Chip;Kim, Ik-Hwan;Lee, Seung-Hwan;Lee, Hoon-Goo;Han, Kyung-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.182-184
    • /
    • 2005
  • The human beings have Increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, intelligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

A Study on Selection of a Control Slope for Daylight Responsive Dimming Systems (광센서 조광제어시스템의 제어기울기 선정방법에 관한 연구)

  • Joo, Keun-Tak;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.179-184
    • /
    • 2005
  • The daylight responsive dimming systems, which use daylight and automatically controls the brightness of electric lighting, according to the amount of daylight coming into the indoor, as well as always maintains target illuminance, is an energy saving type system. The control slope that decide the dimming percent for dimming ballast to run this system efficiently should be decided exactly. This research ran performance assessment applying daylight responsive dimming systems to actual space, and supplemented control slope in the sky condition for the elevation of system. Also we revaluated a system by modified control slope and compiled valid propriety and alternative for the elevation system.

  • PDF

Techniques of Management and Energy saving by using Power installation (전력 사용설비의 에너지 절감방안 및 관리를 위한 진단기법)

  • Lee, S.C.;Jeon, K.Y.;Harm, N.G.;Kim, D.G.;Kang, S.W.;Oh, B.H.;Lee, H.G.;Han, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1102-1104
    • /
    • 2003
  • The human beings have increased concern about energy saving and alternative energy. The Power demand has increased the growth of industry and the improvement of lift. We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed energy saving by using an electric ballast. The load installation should be promoted to rational power management according to the network, intelligent and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

A Study on Pspice Modeling with CCFL using Piezoelectric Transformer (압전변압기를 이용한 CCFL의 PSPICE 모델링에 관한 연구)

  • Hwang Lak-Hoon;Kim Ju-Rae;Lee Sang-Yong;shin yang-ho;Cho Moon-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.630-633
    • /
    • 2001
  • This paper presents a PSPICE circuit model for the simulation of both static and dynamic characteristics of fluorescent lamps. The model can by utilized for an electric ballast simulation with continuous dimming and transient mode simulation such as step dimming Characteristics of a Rosen-type piezoelectric transformer were analyzed by combining an equivalent circuit with piezoelectric equations and the relation between the characteristics and the dimension of the PT was studied.

  • PDF

Studies on the long-distance ignition circuit using the electric ballast (전자안정기를 이용한 원거리 공진형 이그니터회로에 관한 연구)

  • Kim, Tae-Hun;Lee, Woo-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.237-238
    • /
    • 2014
  • A studies about HID resonanse ignition circuit. it need more than 2kV of the output voltage. then the breakdown voltage of the output capacitor must be higher, size of the capacitor must be larger, and price are higher. so were studied possible ways by resonating by distributing the secondary number of turns of the transformer, it would reduce the breakdown voltage of the output capacitor. we also studied the method can be lit at long distance, to control the resonance frequency in dependence on its parasitic capacitor that vary according to the length of the wire.

  • PDF

Inactivation of Zooplankton Artemia sp. Using Plasma Process (플라즈마 공정을 이용한 동물성 플랑크톤 Artemia sp. 불활성화)

  • Dong-Seog Kim;Young-Seek Park
    • Journal of Environmental Science International
    • /
    • v.32 no.3
    • /
    • pp.197-204
    • /
    • 2023
  • This study aims to inactivate Artemia sp. (Zooplankton) in ballast water through the dielectric barrier discharge (DBD) plasma process. The DBD plasma process has the advantage of enabling direct electric discharge in water and utilizing chemically active species generated by the plasma reaction. The experimental conditions for plasma reaction are as follows; high voltage of 9-22 kV, plasma reaction time of 15-600 s, and air flow rate of 0.5-5.5 L/min. The results showed that the optimal experimental conditions for Artemia sp inactivation were 16 kV, 60 s, 2.5 L/min, respectively. The concentrations of total residual oxidants and ozone generated by plasma reaction increased with an increase of in voltage and reaction time, and the concentration of generated air did not increase above a certain amount.

A Fundamental Study on Analysis of Electromotive Force and Updating of Vibration Power Generating Model on Subway Through The Bayesian Regression and Correlation Analysis (베이지안 회귀 및 상관분석을 통한 지하철 진동발전 모델의 수정과 기전력 분석)

  • Jo, Byung-Wan;Kim, Young-Seok;Kim, Yun-Sung;Kim, Yun-Gi
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.2
    • /
    • pp.139-146
    • /
    • 2013
  • This study is to update of vibration power generating model and to analyze electromotive force on subway. Analysis of electromotive force using power generation depending on classification of locations which are ballast bed and concrete bed. As the section between Seocho and Bangbae in the line 2 subway was changed from ballast bed to concrete bed, it could be analyzed at same condition, train, section. Induced electromotive force equation by Faraday's law was updated using Bayesian regression and correlation analysis with calculate value and experiment value. Using the updated model, it could get 40mV per one power generation in ballast bed, and it also could get 4mV per one power generation in concrete bed. If the updated model apply to subway or any train, it will be more effective to get electric power. In addition to that, it will be good to reduce greenhouse gas and to build a green traffic network.