Collection Performance of an Electret Cabin Air Filter for Fine Particles (자동차용 정전 필터의 미세 입자 포집 특성)

  • Ji, Jun-Ho;Kang, Suk-Hoon;Kim, Dong-Choul;Hwang, Jung-Ho;Yoon, Woong-Sup;Bae, Gwi-Nam
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.85-90
    • /
    • 2001
  • This work presents experimental results of filter media test by using particles from $0.02\;to\;0.6{\mu}m$ in diameter and by applying different charging states. In order to investigate the electret filter performance, the collection efficiency and the pressure drop of filter were measured. The face velocities of test filters varied from 2.4 to 20.4 cm/s. Another experiment setup for the cartridge cabin air filter was used to get an collection efficiency in submicron region. After charging level of electret filter severely decreased, the change of collection efficiency was verified. Experimental results show that the reliability of electret filters can be poor in some conditions.

  • PDF

Effect of Particle Loading on the Collection Performance of an Electret Cabin Air Filter for Submicron Particles (입자 퇴적이 승용차용 정전 필터의 미세 입자 포집 특성에 미치는 영향)

  • Ji, Jun-Ho;Gang, Seok-Hun;Hwang, Jeong-Ho;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1102-1114
    • /
    • 2002
  • An electret filter is composed of permanently charged electret fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using poly-disperse particles when submicron particles were loaded. Long-term experiments were conducted by applying two different charging states, which were spray electrification and charge equilibrium by bipolar ionization. In order to investigate the effect of particle loading in filter media, NaCl particles were generated from 0.1% and 1% solutions by an atomizer. Liquid DOS particles were used to evaluate the effect of liquid particles on the collection efficiency of an electret filter. The results show significant effect of charge amount and size distribution of loading particles on the collection performance of a filter media in submicron region. Smaller particles loaded in electret fibers cause a more rapid degradation in collection efficiency and have lower minimum efficiency with time. The pressure drop of a filter media do rarely increase when the collection efficiency decreases to the minimum value. For the larger particles charged by spray electrification, which have charge amounts more than that of Boltzmann equilibrium charge distribution, the pressure drop of a filter media slowly increases in comparison with that of equilibrium charged particles. For DOS particles it is shown that the charging level of an electret filter severely decreases and the collection efficiency is below 10% in some particle size range.

Development of composite filter with high performance meltblown non-woven (고성능 멜트블로운 부직포 복합필터 개발)

  • Lee Jae-Dal;Hong Young-Ki;Bae Kie-Seo
    • Textile Coloration and Finishing
    • /
    • v.17 no.2 s.81
    • /
    • pp.40-45
    • /
    • 2005
  • Electret filter is good enough to protect health and environment from air pollution. The reason why is gathering particles not only by mechanical mechanism but also by electrostatic attraction. Especially this filter is shown lower pressure drop than general mechanical filters as glass fiber. For making electret filter media using polypropylene meltblown(M/B) nonwoven, the nonwoven is charged with corona which was supplied high voltage DC, AC, and pulse with DC power. The electret filter media is tested with $0.3{\mu}m$ sodium chloride and dioctyl phthalate(DOP) aerosol. Results revealed that filtration performance of electret filter media increased as corona was applied with higher voltage and with AC power rather than DC, and fiber diameter was fine and uniform.

Field Application of a Double Filtration Process to Control Fine Dust in a Metro Subway Station (도시 지하역사 미세먼지제어를 위한 이중여과장치의 현장적용 연구)

  • Park, Haewoo;Kim, Wooram;Jo, Youngmin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.5
    • /
    • pp.625-633
    • /
    • 2013
  • This study attempted to find an alternative method for fine dust control in the pre-exiting facilities of metro-subway stations. A new double-layer design was proposed for the MVAC (mechanical ventilation and air control) system. Several filter lay-outs were combined a pre-filter with electret filter (EF), electret bundle filter (EBF), or electret pleated filter (EPF), and were then examined focusing on the collection efficiency of particulate matters and pressure drop across the filter layers. The experimental results from the lab and field tests showed the best collection efficiency with EPF, which achieved 85% for $PM_{10}$ and 55% for $PM_{2.5}$. It was also found from the long term field test that the new filter lay-out could provide quite consistent dust level particularly in underground platform regardless of external condition.

Charge Depletion Effect on Collection Efficiency of an Electret Cabin Air Filter for Submicron Particles (승용차용 정전 필터 내의 정전 섬유의 보유 하전 감쇄에 의한 미세 입자 포집효율 변화)

  • Ji, Jun-Ho;Kang, Suk-Hoon;Hwang, Jung-Ho;Bae, Gwi-Nam
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.71-76
    • /
    • 2001
  • An electret filter is composed of permanently charged electet fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using poly-disperse particles when submicron particles are loaded. Long-term experiments were conducted by applying different charging states, which are spray electrification and charge equilibrium by bipolar ionization. In order to investigate on the effect of particle loading in filter media, NaCl particles were generated from 0.1% and 1% solutions by an atomizer. In NaCl 0.1%, the collection efficiency of electret filter decreased and then did not change in equilibrium state. In the case of relative larger particles of NaCl 1%, collection efficiency for the equilibrium charged particles increases due to the particle loading on the filter fibers. Particles charged by spray electrification are small in collection efficiency after equilibrium state and increase of filter media's pressure drop was very low in comparison of the equilibrium charged particles.

  • PDF

Characteristic Analysis of Electret Filters made by Electrospinning (전기방사를 통한 정전필터제조 및 특성분석)

  • Ahn, Young-Chull;Kim, Gil-Tae;Kim, Seong-Kon;Lee, Jae-Keun;Kim, Jong-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1134-1138
    • /
    • 2008
  • Electret filter media are used in general ventilation filters, disposable respirators, vehicle cabin filters, vacuum cleaners and room air cleaners. There are basic mechanisms of interception, inertial impaction, diffusion, gravitational settling, electrostatic attraction by which an aerosol particle can be deposited onto a fiber in a filter. The ability of fine particle removal strongly depends on the electrostatic forces between particles and polarized fibers. Thus, the stability of the fiber polarization is a major factor in the reliability of electret filters. In this study, electrical properties and filtration performance of electrospun filter media are quantitatively investigated. Electrical properties of electrospun filters have been studied on surface charge potential and surface charge density. Also the filtration performance of the electret filters are evaluated on collection efficiency. Electrospun filters show same collection efficiency with low pressure drop compare to commercialized HEPA filters. Surface charge potential and surface charge density of electrospun filters are increased with increasing applied voltage. Also collection efficiency of electrospun filters is increased with increasing surface charge potential and surface charge density.

  • PDF

Characteristic Analysis of Electret Filters made by Electrospinning (전기방사를 통해 제조된 정전기 보유 필터의 표면전위 및 대전량에 따른 성능특성 분석)

  • Kim, Gil-Tae;Ahn, Young-Chull;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.820-824
    • /
    • 2008
  • Electret filter media are used in general ventilation filters, disposable respirators, vehicle cabin filters, vacuum cleaners and room air cleaners. There are basic mechanisms of interception, inertial impaction, diffusion, gravitational settling, electrostatic attraction by which an aerosol particle can be deposited onto a fiber in a filter. The ability of fine particle removal strongly depends on the electrostatic forces between particles and polarized fibers. Thus, the stability of the fiber polarization is a major factor in the reliability of electret filters. In this study, the electret filter is made by electrospinning process using Polystyrene which is dissolved by 5 : 5 of Tetrahydrofuran (THF) and Dimethylformamide (DMF). Also the electrical properties and the filtration performances of electrospun filter media are Quantitatively investigated. Electrical properties of electrospun filters have been studied on surface charge potential and surface charge density. Also the filtration performance of the electret filters are evaluated on collection efficiency. The surface charge potential and the surface charge density of electrospun PS filters are increased with increasing applied voltage and saturated at 30 kV of applied voltage. Also collection efficiency of electro spun filters is increased with increasing surface charge potential and surface charge density. But the surface charge potential is decreased by natural decay and it causes deterioration of particle collection efficiency.

Collection Performance of an Electret Cabin Air Filter for Fine Particles (승용차용 정전 필터의 미세 입자 포집 특성)

  • Ji, Jun-Ho;Gang, Seok-Hun;Kim, Dong-Cheol;Hwang, Jeong-Ho;Yun, Ung-Seop;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1650-1658
    • /
    • 2001
  • An electret filter is composed of permanently charged electret fibers and is widely used in applications requiring high collection efficiency and low-pressure drop. In this work, the fractional collection efficiency of the filter media used in manufacturing cabin air filters was investigated by using highly monodisperse particles ranging from 0.02 to 0.6 $\mu\textrm{m}$ in diameter at three different charging states: singly charged, uncharged, and equilibrium charged. The face velocity was varied from 2.4 to 20.4 crus. It was fecund that the fractional efficiency curve fur singly charged particles shows a typical trend that the collection efficiency is minimum at about 0.3 $\mu\textrm{m}$ in diameter. The fractional efficiency of equilibrium charged particles were not severely varied with the particle diameter. The collection efficiency curve fur uncharged particles has a minimum near 0.1 $\mu\textrm{m}$ in diameter. Another experiment was conducted for a cartridge filter to examine the effect of charge depletion on the collection efficiency in a cabin air filter. The result shows that the charge depletion of the cartridge filter can significantly lower the collection efficiency.

Performance Test of Air Filter Media (필터여재의 성능평가)

  • Ahn, K.H.;Bae, G.N.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.417-426
    • /
    • 1994
  • Filter media performance was evaluated using monodisperse NaCl particles with Differential Mobility Analyzer and Ultrafine Condensation Particle Counter. Low or medium performance filters show that the most penetrating particles size(MPPS) is around $0.3{\mu}m$ in diameter and is shifted to smaller sizes as the filter face velocity increases. However, HEPA and ULPA filters show MPPS is around $0.15{\mu}m$ in diameter and is also shifted to $0.1{\mu}m$ in diameter as the face velocity increases. In case of electret filter, the MPPS is found around $0.04{\mu}m$ region for Boltzmann charge equilibrium particles. There is a tendency of strong collection efficiency decrease for large particles as the face velocity increases on the contrary to the other filters. One of the medium performance filter efficiency was compared with filtration theory and the good agreetment was found in the experimental range.

  • PDF

A Study on the Collection Efficiency Characteristic in Electret filter (Electret filter의 포집 효율의 특성에 관한 연구)

  • 김은권;정진도
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.121-122
    • /
    • 2000
  • 현재, 반도체 등의 정밀 공업제품의 제조 기술의 발전에 따라서, 공기중의 미세 입자 제거 기술의 고도화가 요구되어 지고 있다. 이러한 미세 입자 제거에 사용되는 물질중 섬유층 필터는 구조가 단순하고, 여러 가지의 집진 조건에 비교적 용이하게 사용이 가능하여, 오늘날 폭넓은 분야에서 사용되어 왔다. 이러한 고성능의 포집 효율을 위한 노력으로, 섬유경을 작게하에 제작된 HEPA필터등이 이제까지의 청정공기의 생성에 널리 이용되어 왔지만, 장치를 대형화하지 않고서는 고포집효율, 저압력손실로 대량의 공기를 처리하는 것에는 한계가 있으며, 섬유경이 작게 되면, 압력손실이 증가되고, 압력손실의 증가는 동력 비용을 높이는 결과와 함께, 섬유 충진율의 분균일성등의 문제점이 발생한다. (중략)

  • PDF