• 제목/요약/키워드: Elastomeric Bearing(EB)

검색결과 3건 처리시간 0.092초

근사모델을 이용한 의 구조최적설계 (Structural Optimization of an LMU Using Approximate Model)

  • 한동섭;장시환;박순형;이권희
    • 한국기계가공학회지
    • /
    • 제17권6호
    • /
    • pp.75-82
    • /
    • 2018
  • This study suggests an optimal design process of an LMU, which is installed on the top side of offshore structures. The LMU is consist of EB(elastomeric bearing) and steel plate, and supports the vertical loads of offshore structures and assists its stable installation. The structural design requirement of the LMU is related to its stiffness. This study utilizes the finite element analysis to predict the stiffness. The stiffness of the EB depends on the size of the bearing. Thus, the design variables in this study are defined as the thickness, the width and the number of plates. Since the LMU has different loads for different locations, its stiffness should be designed differently. The multiobjective function is introduced to attain the target stiffness. In this process, the metamodel using the kriging interpolation method is adopted to replace the true stiffness.

LMU용 일래스토머릭 베어링의 강성평가 (Stiffness evaluation of elastomeric bearings for leg mating unit)

  • 한동섭;장시환;이권희
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.106-111
    • /
    • 2017
  • 본 연구에서는 해양구조물의 상부(top side) 구조물을 설치할 때 필요한 장치인 LMU(Leg Mating Unit)의 강성을 구조해석을 통하여 검토하였다. 이것은 구조물의 지지 점에 장착되어 설치 시 충격을 흡수하고 안정적으로 구조물을 지지하는 데 사용된다. LMU는 가운데가 비어있는 원통형 구조로서 수직 하중을 지지하기 위해서 일래스토머릭 베어링(Elastomeric Bearing, 이하 EB)과 철판을 여러 층으로 적층한다. EB의 강성은 기본적으로 베어링의 크기에 영향을 받지만, 동일한 크기에서도 내부 보강판의 적층 수에 따라 강성이 변하게 된다. 일반적으로 보강판과 압축 강성 사이의 관계를 분석하여 적합한 설계를 한다. EB의 강성은 변위를 제어하면서 반력을 산출하는 방식으로 분석을 한다. 먼저 보강판의 크기와 압축 강성 관계를 검토하고, 보강판의 적층 수와 압축 강성 관계를 검토한다. LMU는 장착되는 지점마다 다른 하중이 요구된다. 해석을 통해 각 지점에서 동일한 변형이 발생하도록 압축 강성을 다르게 설계하는 것이 목표이다. 본 연구의 유한요소해석을 위하여 상용 프로그램인 ANSYS를 이용하였다.

Seismic performance of a resilient low-damage base isolation system under combined vertical and horizontal excitations

  • Farsangi, Ehsan Noroozinejad;Tasnimi, Abbas Ali;Yang, T.Y.;Takewaki, Izuru;Mohammadhasani, Mohammad
    • Smart Structures and Systems
    • /
    • 제22권4호
    • /
    • pp.383-397
    • /
    • 2018
  • Traditional base isolation systems focus on isolating the seismic response of a structure in the horizontal direction. However, in regions where the vertical earthquake excitation is significant (such as near-fault region), a traditional base-isolated building exhibits a significant vertical vibration. To eliminate this shortcoming, a rocking-isolated system named Telescopic Column (TC) is proposed in this paper. Detailed rocking and isolation mechanism of the TC system is presented. The seismic performance of the TC is compared with the traditional elastomeric bearing (EB) and friction pendulum (FP) base-isolated systems. A 4-storey reinforced concrete moment-resisting frame (RC-MRF) is selected as the reference superstructure. The seismic response of the reference superstructure in terms of column axial forces, base shears, floor accelerations, inter-storey drift ratios (IDR) and collapse margin ratios (CMRs) are evaluated using OpenSees. The results of the nonlinear dynamic analysis subjected to multi-directional earthquake excitations show that the superstructure equipped with the newly proposed TC is more resilient and exhibits a superior response with higher margin of safety against collapse when compared with the same superstructure with the traditional base-isolation (BI) system.