• 제목/요약/키워드: Elastic work factor

검색결과 61건 처리시간 0.028초

CLS 시편의 탄성일인자 유도 및 이를 적용한 열가소성 Graphite/Peek 복합재의 파괴인성 $G_c$ 측정 (Elastic Work Factor of CLS Specimen and Determination of $G_c$ for Graphite/Peek Composites by Using the Elastic Work Factor)

  • 이경엽
    • 대한기계학회논문집A
    • /
    • 제20권9호
    • /
    • pp.2792-2799
    • /
    • 1996
  • It was shown in the previous study that the numerically derived elastic work factor for CLS specimen was independent of fiber direction for a unidirectional case. Also, it was proposed the elastic work factor could be used to determine energy release rate from a single test record. In the present study, elastic work factor was derived from a simple beam theory to investigate its dependence on material property and geometric condition. Also, the elastic work factor of CLS specimen was applied experimentally to determine critical energy release rate in order to prove its validity determining critical energy release rate from a single specimen. For this purpose, critical energy release rate determined using the elastic work factor was compared with that determined by the compliance method. The results showed that while elastic work factor is affected by $t_2/t_1$ and $L_2/L_1$ it is independent of fiber angle for a unidirectional case. It was also found that critical energy release rates determined by both methods are comparable each other, thus elastic work factor approach can be used to determine energy release rate from a single test specimen.

정수압이 탄소섬유/에폭시 복합재의 탄성일인자에 미치는 영향 (Effect of Hydrostatic Pressure on the Elastic Work Factor of Graphite/Epoxy Composites)

  • 이지훈;김만태;신명근;한운용;이경엽
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1390-1393
    • /
    • 2003
  • Work factor approach is conveniently used in metal fracture mechanics to determine fracture toughness from a single fracture test. In this work, we investigated the applicability of the work factor approach in order to determine fracture toughness of thick graphite/epoxy composites in the hydrostatic pressure environment from a single fracture test. The effect of hydrostatic pressure on the elastic work factor was studied, The stacking sequence used was multi-directional, [0$^{\circ}$/${\pm}$45$^{\circ}$/90$^{\circ}$]. The hydrostatic pressures applied were 0.1 MPa, 100 MPa, 200 MPa, and 300 MPa. The results showed that the elastic work factor was not affected by the hydrostatic pressure, The elastic work factor decreased in a linear fashion with crack length.

  • PDF

탄성일인자방법을 적용한 단일방향 탄소섬유/에폭시 DCB 시편의 파괴인성 결정 ($G_IC$ determination of unidirectional graphite /epoxy DCB composites from the elastic work factor approach)

  • 이경엽;이중희
    • 대한기계학회논문집A
    • /
    • 제22권3호
    • /
    • pp.540-544
    • /
    • 1998
  • Compliance calibration method is frequently used to determine $G_IC$ from the DCB composite specimen. However, the method requires at least 4 to 5 fracture test (loading-unloading) records. In this study, $G_IC$ of unidirectional graphite/epoxy DCB composites was determined from the elastic work factor approach which uses a single fracture test record. In order to inspect the validity of the elastic work factor approach, $G_IC$ determined from the elastic work factor approach was compared to that of determined from the compliance calibration method. It was shown that $G_IC$ determined from the elastic work factor approach was comparable to that determined from the compliance calibration method. That is, the elastic work factor approach can be used to determine $G_IC$ of unidirectional graphite/epoxy DCB specimen from a single fracture record.

섬유강화 복합재의 $G_ {IC}$ 결정을 위한 일인자방법 (Determination of Mode I Fracture Toughness of Fiber Reinforced Composites by the Elastic Work Factor)

  • 이경엽;고승기
    • 대한기계학회논문집A
    • /
    • 제20권11호
    • /
    • pp.3491-3497
    • /
    • 1996
  • The work factor approach was applied to determine $G_ {IC}$ of fiber reinforced composites (AS4/3501) from a single unidirectional (0-deg) DCB specimen. Elastic work factors of DCB specimen for three different symmetrical staking sequences were derived from a simple bending theory and a finite element method. The results showed that elastic work factors calculated from both methods were comparable each other. In particular, the elastic work factor of DCB specimen with symmetrical stacking sequence is independent of stacking sequence. The $G_ {IC}$ determined from the work factor approach was compared with that determined by the compliance method. The results showed that the work factor approach and the compliance method produce comparable results of $G_ {IC}$. Thus, $G_ {IC}$ can be determined from a single DCB specimen using the work factor approach.

정수압을 받는 일방향 탄소섬유/에폭시 복합재의 파괴인성 결정을 위한 일인자 적용 (Application of Work Factor to Determine Fracture Toughness of Unidirectional Graphite/Epoxy Composites under Hydrostatic Pressure)

  • 이경엽
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.46-49
    • /
    • 2001
  • In this paper. tile validity of work factor approach was investigated to determine compressive fracture toughness of unidirectional graphite/epoxy composites under hydrostatic pressure environment. The elastic work factor was determined under various pressures as a function of delamination length. It was found that elastic work factor was not affected by hydrostatic pressure.

  • PDF

경계요소법에 의한 탄성-점탄성 복합구조체의 계면균열 해석 (Boundary Element Evaluation of Stress Intensity Factor for Interface Crack in Elastic and Viscoelastic Composite Materials)

  • 이상순;김정규;황종근
    • 전산구조공학
    • /
    • 제9권1호
    • /
    • pp.85-91
    • /
    • 1996
  • 이 논문에서는 탄성-점탄성 복합재료의 공유면에 존재하는 계면균열에 대한 해석방법을 제시하고 있다. 먼저 탄성-점탄성 대응원리를 이용하여 탄성해석식으로부터 응력확대계수에 대한 식을 유도하였다. 다음으로 시간영역 경계요소법을 이용하여 균열선단에서의 응력을 계산한 다음 응력확대계수의 값을 구하였다. 수치해석의 결과는 본 논문의 정확성과 응용가능성을 보여준다.

  • PDF

정수압 환경에서 압축하중을 받는 Graphite/Epoxy 적층복합재의 탄성일인자 결정 (Determination of Elastic Work Factor of Graphite/Epoxy Composites Subjected to Compressive Loading under Hydrostatic Pressure Environment)

  • 신명근;이경엽;이중희
    • Composites Research
    • /
    • 제15권5호
    • /
    • pp.14-18
    • /
    • 2002
  • 본 논문에서는 정수압 환경에서 파괴인성 측정을 위한 일인자방법의 적용성을 검토하기 위해 단일방향 및 준등방성으로 적층된 $\textrm{[}0^{\circ}\textrm{]}_{88}$$\textrm{[}0^{\circ}/\pm/45^{\circ}/90^{\circ}\textrm{]}_{11s}$의 탄소섬유/에폭시 적층복합재에 있어 네 단계 정수압에 대해 탄성일인자를 층간 분리 길이의 함수로 결정 정수압 및 적층각이 탄성일인자에 미치는 영향을 검토하였다. $\textrm{[}0^{\circ}\textrm{]}_{88}$ 경우에는 0.1 MPa, 70MPa, 140MPa, 200MPa의 정수압력을 적용하였으며 $\textrm{[}0^{\circ}/\pm/45^{\circ}/90^{\circ}\textrm{]}_{11s}$에서는 0.1MPa, 100MPa, 200MPa, 300MPa의 정수압력을 적용하였다. 결과로서 탄성일인자는 정수압 및 두 경우 적층각에 의해 영향을 받지 않음을 알 수 있었다. 또한 탄성일인자는 층간분리가 증가함에 따라 선형적으로 감소함을 알 수 있었다.

단섬유 복합체에서 탄성계수비가 내부응력에 미치는 영향 (Effects of Elastic Modulus Ratio on Internal Stresses in Short Fiber Composites)

  • 김홍건;노홍길
    • 한국공작기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.73-78
    • /
    • 2004
  • The conventional SLT(Shear Lag Theory) which has been proven that it can not provide sufficiently accurate strengthening predictions in elastic regime when the fiber aspect ratio is small. This paper is an extented work to improve it by modifying the load transfer mechanism called NSLT(New Shear Lag Theory), which takes into account the stress transfer across the fiber ends and the SCF(Stress Concentration Factor) that exists in the matrix regions near the fiber ends. The key point of the model development is to determine the major controlling factor among the material and geometrical coefficients. It is found that the most affecting factor is the fiber/matrix elastic modulus ratio. It is also found that the proposed model gives a good result that has the capability to correctly predict the elastic properties such as interfacial shear stresses and local stress variations in the small fiber aspect ratio regime.

Dynamic instability and free vibration behavior of three-layered soft-cored sandwich beams on nonlinear elastic foundations

  • Asgari, Gholamreza;Payganeh, Gholamhassan;Fard, Keramat Malekzadeh
    • Structural Engineering and Mechanics
    • /
    • 제72권4호
    • /
    • pp.525-540
    • /
    • 2019
  • The purpose of the present work was to study the dynamic instability of a three-layered, symmetric sandwich beam subjected to a periodic axial load resting on nonlinear elastic foundation. A higher-order theory was used for analysis of sandwich beams with soft core on elastic foundations. In the higher-order theory, the Reddy's third-order theory was used for the face sheets and quadratic and cubic functions were assumed for transverse and in-plane displacements of the core, respectively. The elastic foundation was modeled as nonlinear's type. The dynamic instability regions and free vibration were investigated for simply supported conditions by Bolotin's method. The results showed that the responses of the dynamic instability of the system were influenced by the excitation frequency, the coefficients of foundation, the core thickness, the dynamic and static load factor. Comparison of the present results with the published results in the literature for the special case confirmed the accuracy of the proposed theory.

단일시편방법의 CLS 시편 적용시 적층성이 미치는 영향 (Effects of Stacking Sequence on the Application of the Single Specimen Technique to CLS Specimen)

  • 이경엽;양준호
    • 대한기계학회논문집A
    • /
    • 제23권11호
    • /
    • pp.1952-1959
    • /
    • 1999
  • The work factor approach, so-called single specimen technique could be used to determine energy release rate from a single test record for unidirectional CLS specimen. In the present study, the work factor approach was extended to determine the mixed-mode fracture toughness of multi-directional graphite/epoxy laminated composites. Multi-directional CLS specimens were used for fracture tests. The stacking sequences used for the lap and the strap were $[90_2/0_2]_s/[0_4/90_4]_s$ and $[0/\pm45/0]_s/[0_2/\pm45_2/0_2]_2$, respectively. For both cases, the fracture toughness determined from the work factor approach was compared with that determined from the compliance method. It was found that both methods produced fracture toughness within a maximum 15% difference for each stacking sequence. The fractography analysis also showed that the fiber bridging occurred for$[0/\pm45/0]_s/[0_2/\pm45_2/0_2]_2$ case while it did not occur for $[90_2/0_2]_s/[0_4/90_4]_s$ case.