• 제목/요약/키워드: Elastic wall

검색결과 366건 처리시간 0.026초

Wall charge effects on structural properties of a coarse-grained FENE polyelectrolyte confined in slit nanochannels by Brownian dynamics simulation

  • Jeon, Jong-Gu;Chun, Myung-Suk
    • Korea-Australia Rheology Journal
    • /
    • 제19권2호
    • /
    • pp.51-59
    • /
    • 2007
  • A polyelectrolyte chain confined in a slit nanochannel exhibits a structural transition from the one in free space. In this paper, the effect of the long-range electrostatic interactions between the xanthan polyelectrolyte and the slit wall on the confined xanthan conformation is investigated via the Brownian dynamics simulation. A neutral and two negatively charged surfaces of polydimethylsiloxane (PDMS) and glass are combined to make four kinds of slit channels with different charge characteristics: i) neutral-neutral, ii) glass-glass, iii) neutral-PDMS and iv) neutral-glass walls. Their walls are characterized by uniform surface charge densities determined from experimental data of zeta potential. Both the nonmonotonic chain size variation and the loss of long-range bond vector correlation, previously observed under confinement in the PDMS-PDMS slit, are also found in the neutral slit, demonstrating the nonelectrostatic origin of such crossover behaviors. As expected, the effect of wall charges is negligible at sufficiently high medium ionic strength of 100mM but it becomes significant in the opposite limit of 0.01mM. In the latter case, the high charge density of glass walls strengthens the effective confinement of a negatively charged polyelectrolyte and produces a xanthan structure comparable to that confined in a much narrower neutral slit. The obtained structural data suggest the possibility of controlling the structure of confined polyelectrolytes by the modification of surface charge characteristics of micro/nanofluidic devices in combination with the adjustment of the medium ionic strength.

철근콘크리트 벽체구조물에 대한 등가단자유도 방법 및 등가 감쇠비 산정방법에 따른 역량스펙트럼해석 (Capacity Spectrum Analysis using Equivalent SDOF Method and Equivalent Damping Method for RC Wall Structure)

  • 송종걸;장동휘;김학수;정영화
    • 한국전산구조공학회논문집
    • /
    • 제21권2호
    • /
    • pp.169-187
    • /
    • 2008
  • 기존의 하중-기반 방법을 대체할 방법중에 성능-기반 방법이 내진설계 및 내진성능평가의 기법으로서 널리 인식되고 있는 실정이다. 탄성응답스펙트럼을 사용하는 역량스펙트럼방법은 비선형 시스템을 등가의 선형시스템으로 치환하여 주어진 지진 하중에 대한 구조물의 최대 비선형 거동을 예측한다. 본 연구의 목적은 철근콘크리트 벽체구조물에 대하여 4개의 등가단자유도방법과 5개의 등가감쇠방법을 사용하여 역량스펙트럼방법의 정확성을 평가하는 것이다. 역량스펙트럼방법의 정확성을 평가하기 위하여 벽체구조물에 대한 진동대 실험결과와 비교하였다. 또한 이선형 곡선변환방법(등가에너지 근사화방법, 유효강성 사화 방법)에 의한 이선형 역량곡선들의 역량스펙트럼 해석에 대한 영향도 비교하였다.

중층 종합병원 건물의 내진성능평가 (Seismic Performance Evaluation of a Mid-rise General Hospital Building)

  • 김태완;추유림;김승래
    • 한국지진공학회논문집
    • /
    • 제21권5호
    • /
    • pp.245-254
    • /
    • 2017
  • The building which are essential for disaster recovery is classified as a special seismic use group. Especially, achievement of seismic performance is very important for the hospital, so the hospital should be able to maintain its function during and right after an earthquake without significant damage on both structural and non-structural elements. Therefore, this study aimed at checking the seismic performance of a hospital building, but which was limited to structural elements. For the goal, a plan with a configuration of general hospitals in Korea was selected and designed by two different seismic-force-resisting systems. In analytical modeling, the shear behavior of the wall was represented by three inelastic properties as well as elastic. Nonlinear dynamic analyses were conducted to evaluate the performance of structural members. The result showed that the performance of shear walls in the hospital buildings was not satisfied regardless of the seismic-force-resisting systems, while the demands on the beams and columns did not exceed the capacities. This is the result of only considering the shear of the wall as the force-controlled action. When the shear of the wall was modeled as inelastic, the walls were yielded in shear, and as the result, the demands for frames were increased. However, the increase did not exceed the capacities of the frames members. Consequently, since the performance of walls is significant to determine the seismic performance of a hospital building, it will be essential to establish a definite method of modeling shear behavior of walls and judging their performance.

Analytical investigation on lateral load responses of self-centering walls with distributed vertical dampers

  • Huang, Xiaogang;Zhou, Zhen;Zhu, Dongping
    • Structural Engineering and Mechanics
    • /
    • 제72권3호
    • /
    • pp.355-366
    • /
    • 2019
  • Self-centering wall (SCW) is a resilient and sustainable structural system which incorporates unbonded posttensioning (PT) tendons to provide self-centering (SC) capacity along with supplementary dissipators to dissipate seismic energy. Hysteretic energy dissipators are usually placed at two sides of SCWs to facilitate ease of postearthquake examination and convenient replacement. To achieve a good prediction for the skeleton curve of the wall, this paper firstly developed an analytical investigation on lateral load responses of self-centering walls with distributed vertical dampers (VD-SCWs) using the concept of elastic theory. A simplified method for the calculation of limit state points is developed and validated by experimental results and can be used in the design of the system. Based on the analytical results, parametric analysis is conducted to investigate the influence of damper and tendon parameters on the performance of VD-SCWs. The results show that the proposed approach has a better prediction accuracy with less computational effects than the Perez method. As compared with previous experimental results, the proposed method achieves up to 60.1% additional accuracy at the effective linear limit (DLL) of SCWs. The base shear at point DLL is increased by 62.5% when the damper force is increased from 0kN to 80kN. The wall stiffness after point ELL is reduced by 69.5% when the tendon stiffness is reduced by 75.0%. The roof deformation at point LLP is reduced by 74.1% when the initial tendon stress is increased from $0.45f_{pu}$ to $0.65f_{pu}$.

Whole-working history analysis of seismic performance state of rocking wall moment frame structures based on plastic hinge evolution

  • Xing Su;Shi Yan;Tao Wang;Yuefeng Gao
    • Earthquakes and Structures
    • /
    • 제26권3호
    • /
    • pp.175-189
    • /
    • 2024
  • Aiming at studying the plastic hinge (PH) evolution regularities and failure mode of rocking wall moment frame (RWMF) structure in earthquakes, the whole-working history analysis of seismic performance state of RWMF structure based on co-operation performance and PH evolution was carried out. Building upon the theoretical analysis of the elastic internal forces and deformations of RWMF structures, nonlinear finite element analysis (FEA) methods were employed to perform both Pushover analysis and seismic response time history analysis under different seismic coefficients (δ). The relationships among PH occurrence ratios (Rph), inter-story drifts and δ were established. Based on the plotted curve of the seismic performance states, evaluation limits for the Rph and inter-story drifts were provided for different performance states of RWMF structures. The results indicate that the Rph of RWMF structures exhibits a nonlinear evolution trend of "fast at first, then slow" with the increasing of δ. The general pattern is characterized by the initial development of beam hinges in the middle stories, followed by the development towards the top and bottom stories until the beam hinges are fully formed. Subsequently, the development of column hinges shifts from the bottom and top stories towards the middle stories of the structure, ultimately leading to the loss of seismic lateral capacity with a failure mode of partial beam yield, demonstrating a global yielding pattern. Moreover, the limits for the Rph and inter-story drifts effectively evaluate the five different performance states of RWMF structures.

L형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 골조 구조물의 전단 거동 분석 (Analysis on the Shear Behavior of Existing Reinforced Concrete Frame Structures Infilled with L-Type Precast Wall Panel)

  • 유승룡;주호성;하수경
    • 복합신소재구조학회 논문집
    • /
    • 제6권2호
    • /
    • pp.105-117
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

FRP로 보강한 비보강 조적 벽체의 전단강도 산정 (Evaluation of Shear Strength of Unreinforced Masonry Walls Retrofitted by Fiber Reinforced Polymer Sheet)

  • 배백일;윤효진;최창식;최현기
    • 콘크리트학회논문집
    • /
    • 제24권3호
    • /
    • pp.305-313
    • /
    • 2012
  • 비보강 조적조 건축물은 전세계적으로 기존의 건물 및 역사 건축물의 많은 부분을 차지하고 있다. 특히, 최근 지진이 전세계적으로 빈번하게 나타남에 따라 비보강 조적조 구조물에 대한 내진 보강 대책이 요구되고 있다. 현재 비보강 조적조의 보강방법으로는 숏크리트, ECC jacketing, FRPs(fiber reinforced polymer sheet) 등이 개발되어 사용되고 있다. 특히 많은 엔지니어들이 FRPs를 사용한 보강방법을 채택하는 경향이 보이는데 이는 숏크리트나 ECC jacketing과는 달리 벽체의 두께 확장에 따른 구조물 자중 증가 문제없이 비보강 조적조의 전단강도를 향상시킬 수 있기 때문이다. 그러나 비보강 조적 벽체의 복잡한 역학적 거동과 FRPs를 사용한 실험 데이터의 부족은 아직까지도 적절한 보강량을 산정하는데 어려움을 주고 있다. 이 연구는 비보강 조적조의 면내 거동을 확인하고 두 가지의 다른 특징을 가진 FRPs를 사용한 보강 효과에 대한 정보를 주기 위해 수행되었다. 실험체는 1970년대 한국에서 빈번하게 지어진 저층형 연립주택의 내벽을 대상으로 하고 있으며 별도의 내진 설계는 되어있지 않은 상태이다. 실험체의 형상비는 실제 상황을 반영하기 위해 1에 가깝게 설정되어 있다. 보강 재료로는 탄소섬유보강 시트와 하이브리드 시트를 사용하였으며 이들은 각각 다른 극한 강도와 탄성계수 및 극한 변형률을 보유하고 있다. 연구 결과 비보강 조적 벽체의 면내 전단력 저항 성능을 확인하였으며 FRPs가 사용된 내진 보강 방안의 특성을 분석할 수 있었다. 또한 FRPs를 사용한 보의 전단보강 방법에 착안하여 비보강 조적조에 대한 FRPs의 보강 설계안을 도출할 수 있었다.

지표면 재하시 사질토 지반의 상대밀도에 따른 지중 연직응력분포 특성 (Characteristics of Vertical Stress Distribution in Soil according to the Relative Density of Sandy Soil in case of Surface Loading)

  • 임종석;이인형;정원중
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.422-426
    • /
    • 2003
  • Model soil tank tests were conducted in sandy soil to investigate the effect of surcharge strip loads on vertical stress distribution in soil. A total number of 6 tests were performed using one loading plate and two relative density(55%, 65%). The soil was considered as an elastic material, while no friction was allowed between the wall and the soil. Measured stress values were compared to predictions defined by Frohlich, Boussinesq and Westergaard. The comparison of measured values and predictions used the ratio between the soil pressure and load value. Results of this study demonstrated that experimental values were generally larger than predictions. The Frohlich analysis provided the best prediction, while the Boussinesq analysis and Westergaard theory not presented a satisfactional result.

  • PDF

폐쇄형 이중세포로 된 박벽 복합재료 블레이드의 단순화 해석 모델 (A Simple Beam Model for Thin-Walled Composite Blades with Closed, Two-Cell Sections)

  • 정성남;박일주;이주영;이정진
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.187-190
    • /
    • 2005
  • A simple beam model based on a mixed method is proposed for the analysis of thin-walled composite blades with a two-cell airfoil section. A semi-complementary energy functional is used to obtain the beam force-displacement relations. The theory accounts for the effects of elastic couplings, shell wall thickness, warping, and warping restraint. All the kinematic relations as well as the cross-section stiffnesses are evaluated in a closed-form through the current beam formulation. The theory has been applied to two-cell composite blades with extension-torsion couplings and fairly good correlation has been observed in comparison with a detailed analysis and other literature.

  • PDF

강체벽과 충돌하는 한단이 고정된 외팔보의 진동 (Dynamic Contact of a Cantilever Beam with Rigid Wall Condition)

  • 박남규;장영기;김재익;김규태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.436-439
    • /
    • 2005
  • Dynamic contact of a cantilever beam with Sap at the end is discussed. The gap in a structure induces dynamic contact, and the contact problem is always accompanied by inequality constraints which mean that the solution of the structure with contact condition should satisfy variational inequality. Inequality, but, can be reduced to equality condition considering convex penalty function. In this paper, formulation of a beam with contact is derived using quasi convex penalty function. General coordinate solution which is needed to increase computational efficiency is applied. Nonlinear behavior of a beam with rigid and elastic contact condition was discussed.

  • PDF