• Title/Summary/Keyword: Elastic Center

Search Result 694, Processing Time 0.023 seconds

Temperature Dependence on Elastic Constant of SiC Ceramics (SiC 세라믹스 탄성률의 온도 의존성)

  • Im, Jong-In;Park, Byoung-Woo;Shin, Ho-Yong;Kim, Jong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.47 no.6
    • /
    • pp.491-497
    • /
    • 2010
  • In this paper, we employed the classical molecular dynamics simulations using Tersoff's potential to calculate the elastic constants of the silicon carbide (SiC) crystal at high temperature. The elastic constants of the SiC crystal were calculated based on the stress-strain characteristics, which were drawn by the simulation using LAMMPS software. At the same time, the elastic constants of the SiC ceramics were measured at different temperatures by impulse excitation testing (IET) method. Based on the simulated stress-strain results, the SiC crystal showed the elastic deformation characteristics at the low temperature region, while a slight plastic deformation behavior was observed at high strain over $1,000^{\circ}C$ temperature. The elastic constants of the SiC crystal were changed from about 475 GPa to 425 GPa by increasing the temperature from RT to $1,250^{\circ}C$. When compared to the experimental values of the SiC ceramics, the simulation results, which are unable to obtain by experiments, are found to be very useful to predict the stress-strain behaviors and the elastic constant of the ceramics at high temperature.

NEUTRON ELASTIC AND NON-ELASTIC SCATTERING STUDIES IN TENS OF MeV REGION

  • Baba Mamoru;Ibaraki Masanobu;Miura Takako;Aoki Takao;Nakashima Hiroshi;Tanaka Shin-ichiro Meigo Susumu
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.265-270
    • /
    • 2001
  • Experimental data have been obtained on the neutron elastic scattering cross sections for 55, 65 and 75 MeV neutrons, and non-elastic scattering cross sections for 40 to 80 MeV neutrons using the $^7Li(p,n)$ neutron source at TIARA of Japan Atomic Energy Research Institute and the TOF method. Data were obtained for C, Si, Fe, Zr, and Pb of natural elements. Elastic scattering data were obtained for 25 laboratory angles between 2.6 and 53.0 that clarified the angular distributions and angle integrated values. The data obtained were compared favorably with recent LA150 data library.

  • PDF

Axisymmetric bending of a circular plate with stiff edge on a soft FGM layer

  • Volkov, Sergey S.;Litvinenko, Alexander N.;Aizikovich, Sergey M.;Wang, Yun-Che;Vasiliev, Andrey S.
    • Structural Engineering and Mechanics
    • /
    • v.59 no.2
    • /
    • pp.227-241
    • /
    • 2016
  • A circular plate with constant thickness, finite radius and stiff edge lying on an elastic halfspace is considered. The half-space consists of a soft functionally graded (FGM) layer with arbitrary varying elastic properties and a homogeneous elastic substrate. The plate bends under the action of arbitrary axisymmetric distributed load and response from the elastic half-space. A semi-analytical solution for the problem effective in whole range of geometric (relative layer thickness) and mechanical (elastic properties of coating and substrate, stiffness of the plate) properties is constructed using the bilateral asymptotic method (Aizikovich et al. 2009). Approximated analytical expressions for the contact stresses and deflections of the plate are provided. Numerical results showing the qualitative dependence of the solution from the initial parameters of the problem are obtained with high precision.

Influence of a soft FGM interlayer on contact stresses under a beam on an elastic foundation

  • Aizikovich, Sergey M.;Mitrin, Boris I.;Seleznev, Nikolai M.;Wang, Yun-Che;Volkov, Sergey S.
    • Structural Engineering and Mechanics
    • /
    • v.58 no.4
    • /
    • pp.613-625
    • /
    • 2016
  • Contact interaction of a beam (flexible element) with an elastic half-plane is considered, when a soft inhomogeneous (functionally graded) interlayer is present between them. The beam is bent under the action of a distributed load applied to the surface and a reaction of the elastic interlayer and the half-space. Solution of the contact problem is obtained for different values of thickness and parameters of inhomogeneity of the layer. The interlayer is assumed to be significantly softer than the underlying half-plane; case of 100 times difference in Young's moduli is considered as an example. The influence of the interlayer thickness and gradient of elastic properties on the distribution of the contact stresses under the beam is studied.

The Immediate Effects of Elastic Taping on Center of Pressure and Foot Pressure Distribution

  • Jung-Hee Kim;Jong-Ho Kook;Sang-Mi Lee;Eun-Bin Ko;Song-Yi Han;Yeon-Jeong Kim;Byeong-Jun Min
    • PNF and Movement
    • /
    • v.22 no.1
    • /
    • pp.23-30
    • /
    • 2024
  • Purpose: Ankle instability is a common issue in both daily activities and sports, often leading to recurrent injuries. Elastic taping is a non-pharmacological intervention used to improve ankle stability. This study aimed to investigate the immediate effects of elastic taping on ankle stability, center of pressure (COP) movement, and foot pressure distribution. Methods: A single-group pre-posttest design was employed, with 30 participants included in the study. Plantar pressure and COP parameters were measured before and after the application of elastic taping. Taping was administered in three distinct patterns to enhance ankle stability. Results: Immediate effects of elastic taping were evident in COP parameters. Following taping application, there was a significant decrease in COP total displacement, COP area, and COP velocity. However, no significant changes were observed in plantar pressure parameters. Conclusion: The application of elastic taping in this study demonstrated immediate effects on ankle stability and COP parameters, indicating its potential as a viable intervention for improving balance. Further research with larger sample sizes and long-term follow-up is needed to elucidate the sustained effects of elastic taping on ankle stability.

Immediate Effect of Elastic Taping on Postural Sway in Patients with Stroke

  • Cho, Kyun Hee;Park, Shin Jun
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.9 no.4
    • /
    • pp.1631-1635
    • /
    • 2018
  • Stroke can cause leg weakness, sensory abnormalities, and balance disorders. The purpose of this study was to investigate the effect of elastic taping on postural sway in patients with stroke. This study randomly applied elastic taping to 20 patients with stroke in two ways. The center of pressure (COP) distribution was measured before and after the elastic taping. The measurement variables were COP area and length, and measurements were performed immediately after taping. The elastic taping on tibialis anterior muscle showed a significant decrease in COP area and length compared to that without elastic taping. The elastic taping on gastrocnemius muscles showed a significant decrease in COP area and length compared to that without elastic taping. There was no significant difference in COP area and length between the elastic taping on tibialis anterior muscle and gastrocnemius muscles. Our results suggested that applying elastic taping on the ankle joints is effective in decreasing postural sway after in patients with stroke.

Effects of elastic band orthosis (aider) on balance and gait in chronic stroke patients

  • Daher, Noha;Lee, Seungjun;Yang, You Jin
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.2
    • /
    • pp.81-86
    • /
    • 2013
  • Objective: The objective of this study was to investigate the feasibility and effects of balance training using a newly developed elastic band orthosis (aider) for improvement of mobility and balance in chronic stroke patients. Design: Cross-sectional study. Methods: Ten patients with chronic hemiplegia participated in this study. There were six males and four females; two patients had right hemiplegia and eight had left hemiplegia. This study investigated the effect of the elastic band orthosis on balance and gait ability compared with bare foot condition. Gait parameters were measured using the opto-gait system for analysis of the spatial and temporal parameters of walking in stroke patients. In addition, balance ability in stroke patients was evaluated using the Timed Up and Go (TUG) and Berg Balance Scale (BBS). Results: This study investigated the effect of the elastic band orthosis on balance compared with bare foot condition. The TUG and BBS showed significant improvement with use of the elastic band orthosis (p<0.05). Use of the Elastic band orthosis resulted in significantly improved velocity, cadence, less-affected step length, less-affected stride length, and less-affected single limb support in stroke patients (p<0.05). Conclusions: We demonstrated a significant improvement in dynamic balance and gait ability in chronic stroke patients using the elastic band orthosis. This orthosis may aid in prevention of spastic foot drop, leading to improvement of walking ability.

Elastic Liposome Formulation for Transdermal Delivery of Rutin (루틴의 피부 흡수 증진을 위한 탄성 리포좀 제형 연구)

  • Lim, Myoung-Sun;Han, Seat-Byeol;Kwon, Soon-Sik;Park, Min-A;Park, Soo-Nam
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.38 no.2
    • /
    • pp.147-154
    • /
    • 2012
  • In this study, we prepared elastic liposome containing rutin, known as antioxidants, and evaluated the physical characterization and enhanced skin permeation effect. The elastic liposome was prepared using the different ratios of egg phospholipids and $Tego^{(R)}$ care 450. The mean diameter of rutin loaded elastic liposomes formulations ranged between 205.7 ~ 298.0 nm and deforability 20.9 ~ 42.5, The loading efficiency was observed to be 52.0 ~ 71.0 %. The highest loading efficiency (71.0 %) and deformability (42.5) were observed at the optimal ratio of 85 : 15 (egg phospholipids : $Tego^{(R)}$ care 450) in the 0.1 % rutin loaded elastic liposome formulations. The elastic liposome formulation was selected for further transdermal permeation study. The elastic liposome(129.9 ${\mu}g/cm^2$) exhibited a significantly higher skin permeation compared with general liposome (98.0 ${\mu}g/cm^2$) and 1,3-butylene glycol (76.3 ${\mu}g/cm^2$) solution. These results suggest that the elastic liposome formulation using $Tego^{(R)}$ care 450 as a major edge activator could be useful for the delivery of active ingredient through the skin barrier.

Molecular dynamic studies for elastic constant of SiC crystal at high temperature (고온에서 SiC 결정의 탄성율에 대한 분자동역학연구)

  • Park, B.W.;Shin, H.R.;Kim, J.H.;Im, J.I.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.5
    • /
    • pp.232-236
    • /
    • 2010
  • Silicon carbide (SiC) ceramics are widely used in the application of high-temperature structural devices due to their light weight as well as superior hardness, fracture toughness, and temperature stability. In this paper, we employed classical molecular dynamics simulations using Tersoff's potential to investigate the elastic constants of the SiC crystal at high temperature. The stress-strain characteristics of the SiC crystal were calculated with the LAMMPS software and the elastic constants of the SiC crystal were analyzed. Based on the stress-strain analysis, the SiC crystal has shown the elastic deformation characteristics at the low temperature region. But the slight plastic deformation behavior was shown as applied the high strain over $1,000^{\circ}C$. Also the elastic constants of the SiC crystal were changed from about 475 GPa to 425 GPa as increased the temperature to $1,250^{\circ}C$.

Effects of Elastic Resistance Exercise Using Proprioceptive Neuromuscular Facilitation on Activities of Daily Living of Patient with Incomplete Spinal Cord Injury -Single Subject Design- (PNF에 기초한 탄력저항운동이 불완전 척수 손상 환자의 일상생활동작에 미치는 효과 -단일사례연구-)

  • Kim, Jwa-Jun;Kim, Min-Soo
    • PNF and Movement
    • /
    • v.14 no.3
    • /
    • pp.245-254
    • /
    • 2016
  • Purpose: This study investigates the influence of elastic resistance exercise using proprioceptive neuromuscular facilitation (PNF) on the daily activities of a patient with incomplete spinal cord injury. The result will be proposed as background data for effective intervention in a patient with incomplete spinal cord injury. Methods: The target subject was a patient with incomplete spinal cord injury to the cervical cord (C6). Elastic resistance exercise based on PNF was performed for 30 min daily, five times a week, for eight weeks. The ASIS motor scale was applied to test the muscular strength of the upper limb, and the spinal cord independence measure II (SCIM II) was used to evaluate the capacity of daily activity. Results: By applying elastic resistance exercise based on PNF, the muscular strength of the upper limb increased and the performance of daily activity improved. Conclusion: Because elastic resistance exercise based on PNF positively influences the ASIA motor scale and SCIM II of the patient with incomplete spinal cord injury. It can be used for training programs to improve the capacity of daily activity of the patient.